{"id":5687,"date":"2021-08-08T10:33:20","date_gmt":"2021-08-08T10:33:20","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=5687"},"modified":"2021-11-21T18:07:51","modified_gmt":"2021-11-21T17:07:51","slug":"course-protection-control-high-voltage-power-circuits","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits\/","title":{"rendered":"Protection and Control of High Voltage Power Circuits"},"content":{"rendered":"<p>This course deals with the protection and control principles of high voltage stations. Starting with system faults and how they affect switchyard configuration and elements, simple \u201cDifferential Protection\u201d is examined along with the maloperation due to CT saturation and mismatch. High voltage circuit breakers are examined as to the various Types (Oil, Vacuum, Air Blast, SF6) and their <strong>closing, tripping, and anti-pumping controls<\/strong>.<\/p>\n<p>The course will pay attention to the Reclosure Syncrocheck relay, as well as Breakers Failure Protection and Dynamic Monitoring Equipment. Transfer and remote tripping are discussed along with the need to provide immunity from ground rise potential and open-circuit situations.<\/p>\n<h2>Course Summary<\/h2>\n<ol>\n<li>Introduction<\/li>\n<li>Overview of Stations<\/li>\n<li>Relaying in General<\/li>\n<li>Instrument Transformers<\/li>\n<li>Transformer Configurations Connections and Cooling<\/li>\n<li>Surge Protective Equipment<\/li>\n<li>High Voltage Circuit Breakers<\/li>\n<li>Breaker Control and Auto Reclosing<\/li>\n<li>Instantaneous and Timed Overcurrent Protection<\/li>\n<li>Differential Protection<\/li>\n<li>Impedance Relaying<\/li>\n<li>The Final Exam With 29 Questions<\/li>\n<\/ol>\n<p><iframe src=\"https:\/\/player.vimeo.com\/video\/583484755?dnt=1&amp;app_id=122963\" width=\"640\" height=\"480\" frameborder=\"0\" allow=\"autoplay; fullscreen; picture-in-picture; clipboard-write\"><\/iframe><\/p>\n<p>For more information, please visit the course page:<\/p>\n<blockquote class=\"wp-embedded-content\" data-secret=\"aPmPVVnKtg\"><p><a href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/protection-control-high-voltage-power-circuits\">Protection and Control of High Voltage Power Circuits<\/a><\/p><\/blockquote>\n<p><iframe class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; clip: rect(1px, 1px, 1px, 1px);\" title=\"&#8220;Protection and Control of High Voltage Power Circuits&#8221; &#8212; EEP Academy Courses\" src=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/protection-control-high-voltage-power-circuits\/embed#?secret=E7W5Gi9ZrD#?secret=aPmPVVnKtg\" data-secret=\"aPmPVVnKtg\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This course deals with the protection and control principles of high voltage power stations and major equipment like transformers, circuit breakers, CTs and VTs. Instantaneous, overcurrent and transformer differential protection are studied. 10 sections in 5h 23min total course length.-<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\">\n<a title=\"Learn more about the couse\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/protection-control-high-voltage-power-circuits\">See course details<\/a>\n<\/div>\n","protected":false},"author":15,"featured_media":12724,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[160,117],"product_tag":[399,129,398,143,1034],"class_list":["post-5687","product","type-product","status-publish","has-post-thumbnail","product_cat-power-substation","product_cat-relay-protection","product_tag-circuit-breakers","product_tag-high-voltage","product_tag-power-station","product_tag-relay-protection","product_tag-substation-protection","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Protection and Control of High Voltage Power Circuits - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"This course deals with the protection and control principles of high voltage power stations, transformers, circuit breakers, CTs and VTs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Protection and Control of High Voltage Power Circuits - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"This course deals with the protection and control principles of high voltage power stations, transformers, circuit breakers, CTs and VTs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-21T17:07:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/course-protection-control-high-voltage-circuits-power-stations-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"778\" \/>\n\t<meta property=\"og:image:height\" content=\"625\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits\",\"name\":\"Protection and Control of High Voltage Power Circuits - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/course-protection-control-high-voltage-circuits-power-stations-1.jpg\",\"datePublished\":\"2021-08-08T10:33:20+00:00\",\"dateModified\":\"2021-11-21T17:07:51+00:00\",\"description\":\"This course deals with the protection and control principles of high voltage power stations, transformers, circuit breakers, CTs and VTs.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/course-protection-control-high-voltage-circuits-power-stations-1.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/course-protection-control-high-voltage-circuits-power-stations-1.jpg\",\"width\":778,\"height\":625,\"caption\":\"Protection and Control of High Voltage Power Circuits\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-protection-control-high-voltage-power-circuits#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Protection and Control of High Voltage Power Circuits\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Protection and Control of High Voltage Power Circuits - EEP Academy Courses","description":"This course deals with the protection and control principles of high voltage power stations, transformers, circuit breakers, CTs and VTs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits","og_locale":"en_US","og_type":"article","og_title":"Protection and Control of High Voltage Power Circuits - EEP Academy Courses","og_description":"This course deals with the protection and control principles of high voltage power stations, transformers, circuit breakers, CTs and VTs.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2021-11-21T17:07:51+00:00","og_image":[{"width":778,"height":625,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/course-protection-control-high-voltage-circuits-power-stations-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits","name":"Protection and Control of High Voltage Power Circuits - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/course-protection-control-high-voltage-circuits-power-stations-1.jpg","datePublished":"2021-08-08T10:33:20+00:00","dateModified":"2021-11-21T17:07:51+00:00","description":"This course deals with the protection and control principles of high voltage power stations, transformers, circuit breakers, CTs and VTs.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/course-protection-control-high-voltage-circuits-power-stations-1.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/course-protection-control-high-voltage-circuits-power-stations-1.jpg","width":778,"height":625,"caption":"Protection and Control of High Voltage Power Circuits"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-protection-control-high-voltage-power-circuits#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Protection and Control of High Voltage Power Circuits"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/5687","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=5687"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/12724"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=5687"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=5687"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=5687"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=5687"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}