{"id":7021,"date":"2021-08-13T10:54:38","date_gmt":"2021-08-13T10:54:38","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=7021"},"modified":"2024-11-13T21:28:56","modified_gmt":"2024-11-13T20:28:56","slug":"course-matlab-simulations-power-electronics","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics\/","title":{"rendered":"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar"},"content":{"rendered":"<p>Learn the leading software MATLAB in numerical computing through step-by-step exercises. In this course, we will learn to simulate AC-DC, DC-AC, AC-AC, and DC-DC converter circuits, electric circuits, electrical machines, solar and synchronous generators in the MATLAB using Simulink tool circuits.<\/p>\n<p><strong>In this course, you will learn the simulation using MATLAB of:<\/strong><\/p>\n<div class=\"wp-block-columns\">\n<div class=\"wp-block-column\">\n<ul>\n<li>Single-phase half wave controlled rectifier<\/li>\n<li>Model the DC machine in a no-load case<\/li>\n<li>Single-phase bridge controlled rectifier<\/li>\n<li>Model the DC machine in presence of load torque<\/li>\n<li>Single-phase AC chopper with R and RL load<\/li>\n<li>Simulating the DC machine using power library<\/li>\n<li>A DC-DC converter as a buck regulator<\/li>\n<li>Three-phase Inverter<\/li>\n<li>Boost regulator<\/li>\n<li>Single-phase half-wave controlled rectifier<\/li>\n<li>Buck-Boost regulator<\/li>\n<li>Induction motor<\/li>\n<li>Single-phase half-bridge inverter<\/li>\n<li>PV cell in solar energy<\/li>\n<li>Single-phase &amp; three-phase bridge inverter<\/li>\n<li>PID controller<\/li>\n<li>Single-phase half-wave controlled rectifier<\/li>\n<li>Analyzing data from the PSCAD program<\/li>\n<\/ul>\n<p><strong>For more information and video preview, please visit the course page:<\/strong><\/p>\n<blockquote class=\"wp-embedded-content\" data-secret=\"SnUs6CKisO\"><p><a href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/matlab-simulink-power-electronics-motors-synchronous-generators\">MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar<\/a><\/p><\/blockquote>\n<p><iframe class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; visibility: hidden;\" title=\"&#8220;MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar&#8221; &#8212; EEP Academy Courses\" src=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/matlab-simulink-power-electronics-motors-synchronous-generators\/embed#?secret=WhAeythaXR#?secret=SnUs6CKisO\" data-secret=\"SnUs6CKisO\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\n<\/div>\n<div class=\"wp-block-column\"><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Learn how to use MATLAB\/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators. 47 lessons in 13h 52m total course length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\">\n<a title=\"Learn more about the couse\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/matlab-simulink-power-electronics-motors-synchronous-generators\">See course details<\/a>\n<\/div>\n","protected":false},"author":9,"featured_media":6826,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[504,338,339],"product_tag":[508,190,343,533,191],"class_list":["post-7021","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-machines","product_cat-matlab-simulink","product_cat-power-electronics","product_tag-electric-motors","product_tag-matlab","product_tag-power-electronics","product_tag-rectifier","product_tag-simulink","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Learn how to use MATLAB\/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Learn how to use MATLAB\/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2024-11-13T20:28:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"634\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics\",\"name\":\"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg\",\"datePublished\":\"2021-08-13T10:54:38+00:00\",\"dateModified\":\"2024-11-13T20:28:56+00:00\",\"description\":\"Learn how to use MATLAB\\\/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg\",\"width\":1000,\"height\":634,\"caption\":\"MATLAB Simulink for power electronics, electric circuits and machines\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-matlab-simulations-power-electronics#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar - EEP Academy Courses","description":"Learn how to use MATLAB\/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics","og_locale":"en_US","og_type":"article","og_title":"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar - EEP Academy Courses","og_description":"Learn how to use MATLAB\/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2024-11-13T20:28:56+00:00","og_image":[{"width":1000,"height":634,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics","name":"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg","datePublished":"2021-08-13T10:54:38+00:00","dateModified":"2024-11-13T20:28:56+00:00","description":"Learn how to use MATLAB\/Simulink for power electronics circuits, electric circuits, electrical machines, solar and synchronous generators.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/matlab-simulink-power-electronics-electric-circuits-machines-solar-synchronous-generators.jpg","width":1000,"height":634,"caption":"MATLAB Simulink for power electronics, electric circuits and machines"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-matlab-simulations-power-electronics#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"MATLAB Simulations using Simulink for Power Electronics, Electric Motors, Generators and Solar"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/7021","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=7021"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/6826"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=7021"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=7021"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=7021"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=7021"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}