{"id":8430,"date":"2021-08-20T10:52:56","date_gmt":"2021-08-20T10:52:56","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=8430"},"modified":"2021-11-12T00:12:54","modified_gmt":"2021-11-11T23:12:54","slug":"course-simaris-design-lv-power-calculations","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations\/","title":{"rendered":"Low Voltage Power Calculations in SIMARIS Design Tool"},"content":{"rendered":"\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Planning of an electrical design project starts with power calculations. This is always the first step in dimensioning a low voltage power system.<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Simaris Design is, according to our experience, <strong>by far the best software to quickly set up a project<\/strong>, create single-line diagrams, and output all the needed documents (project documentation, different list in Excel, e.g. busbar, cable, device settings, selectivity documentation, etc., single-line diagrams in PDF and DWG\/DXF).<\/p>\r\n\r\n\r\n\r\n<p class=\"wp-block-paragraph\">Language support in Simaris Design is great, meaning that you can set your workspace and the single-line diagram <strong>to the language of your choice<\/strong>. The same goes for the output documentation.<\/p>\r\n<h2>Course Summary<\/h2>\r\n<ol>\r\n<li>Download, install and register Simaris Design and Simaris Curves<\/li>\r\n<li>First steps in Simaris \u2013 workspace, sections, settings<\/li>\r\n<li>Basic and advanced single line diagrams<\/li>\r\n<li>Dimensioning power cables (including special topic \u2013 harmonic content)<\/li>\r\n<li>Tips &amp; Tricks on Simaris Design\/Curves and recapitulation<\/li>\r\n<\/ol>\r\n<p><strong>For more information and video preview, please visit the course page:<\/strong><\/p>\r\n<p><blockquote class=\"wp-embedded-content\" data-secret=\"HgPRbxGUa3\"><a href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/low-voltage-power-calculations-simaris-design\">Low Voltage Power Calculations in SIMARIS Design Tool<\/a><\/blockquote><iframe class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; clip: rect(1px, 1px, 1px, 1px);\" title=\"&#8220;Low Voltage Power Calculations in SIMARIS Design Tool&#8221; &#8212; EEP Academy Courses\" src=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/low-voltage-power-calculations-simaris-design\/embed#?secret=RMEx5IdpmT#?secret=HgPRbxGUa3\" data-secret=\"HgPRbxGUa3\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\r\n","protected":false},"excerpt":{"rendered":"<p>Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens. 12 lessons in 1h 25m total course length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\">\n<a title=\"Learn more about the couse\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/low-voltage-power-calculations-simaris-design\">See course details<\/a>\n<\/div>\n","protected":false},"author":17,"featured_media":8365,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[118,145],"product_tag":[164,633,634],"class_list":["post-8430","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-design","product_cat-power-system","product_tag-electrical-design","product_tag-simaris-design","product_tag-single-line-diagram","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Low Voltage Power Calculations in SIMARIS Design Tool - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Low Voltage Power Calculations in SIMARIS Design Tool - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-11T23:12:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/low-voltage-power-calculations-simaris-design-tool.gif\" \/>\n\t<meta property=\"og:image:width\" content=\"1164\" \/>\n\t<meta property=\"og:image:height\" content=\"656\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/gif\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations\",\"name\":\"Low Voltage Power Calculations in SIMARIS Design Tool - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/low-voltage-power-calculations-simaris-design-tool.gif\",\"datePublished\":\"2021-08-20T10:52:56+00:00\",\"dateModified\":\"2021-11-11T23:12:54+00:00\",\"description\":\"Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/low-voltage-power-calculations-simaris-design-tool.gif\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/low-voltage-power-calculations-simaris-design-tool.gif\",\"width\":1164,\"height\":656,\"caption\":\"Low Voltage Power Calculations in Simaris Design Tool\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-simaris-design-lv-power-calculations#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Low Voltage Power Calculations in SIMARIS Design Tool\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Low Voltage Power Calculations in SIMARIS Design Tool - EEP Academy Courses","description":"Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations","og_locale":"en_US","og_type":"article","og_title":"Low Voltage Power Calculations in SIMARIS Design Tool - EEP Academy Courses","og_description":"Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens.","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2021-11-11T23:12:54+00:00","og_image":[{"width":1164,"height":656,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/low-voltage-power-calculations-simaris-design-tool.gif","type":"image\/gif"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations","name":"Low Voltage Power Calculations in SIMARIS Design Tool - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/low-voltage-power-calculations-simaris-design-tool.gif","datePublished":"2021-08-20T10:52:56+00:00","dateModified":"2021-11-11T23:12:54+00:00","description":"Learn how to plan and design low-voltage power distribution systems using this powerful (and free of charge) software from Siemens.","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/low-voltage-power-calculations-simaris-design-tool.gif","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/low-voltage-power-calculations-simaris-design-tool.gif","width":1164,"height":656,"caption":"Low Voltage Power Calculations in Simaris Design Tool"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-simaris-design-lv-power-calculations#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Low Voltage Power Calculations in SIMARIS Design Tool"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/8430","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=8430"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/8365"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=8430"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=8430"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=8430"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=8430"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}