{"id":8782,"date":"2021-08-21T17:16:06","date_gmt":"2021-08-21T17:16:06","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=8782"},"modified":"2021-11-12T00:09:56","modified_gmt":"2021-11-11T23:09:56","slug":"course-industrial-packaging-machine-electrical-design","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design\/","title":{"rendered":"Electrical Design of an Industrial Packaging Machine"},"content":{"rendered":"<p>In this course, we will discuss the\u00a0<strong>Industrial Packaging Machine project<\/strong>. First, we\u2019ll get into the basics, and then with every lesson, we will dig deeper into the project. This course covers the power system, the control system (PLC Siemens S7-1200), and the safety system (SICK Safe EFI-pro System).<\/p>\n<p>We will also explain how the machine is controlled and why we need the input and output signals. By the end of the course, you will understand how to start designing an electrical system for an industrial packaging machine.<\/p>\n<h2>Course Summary<\/h2>\n<ol>\n<li>About the team, Factory, Customer and Special Requirements On This Project<\/li>\n<li>About the machine, the project itself, and different sections in the EPLAN project<\/li>\n<li>Power system and actuators in the project<\/li>\n<li>Safety system analysis in-depth: input, output, special requirements<\/li>\n<li>Standard PLC (S7-1200) analysis: I\/O signals explanation<\/li>\n<\/ol>\n<p><strong>For more information and video preview, please visit the course page:<\/strong><\/p>\n<blockquote class=\"wp-embedded-content\" data-secret=\"LeIkG2SNdU\"><p><a href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/electrical-design-industrial-packaging-machine\">Electrical Design of an Industrial Packaging Machine<\/a><\/p><\/blockquote>\n<p><iframe class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; clip: rect(1px, 1px, 1px, 1px);\" title=\"&#8220;Electrical Design of an Industrial Packaging Machine&#8221; &#8212; EEP Academy Courses\" src=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/electrical-design-industrial-packaging-machine\/embed#?secret=g2Oenss5l3#?secret=LeIkG2SNdU\" data-secret=\"LeIkG2SNdU\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Master electrical design of industrial automation systems &#8211; packaging machine (wiring diagram and PLC (S7-1200) analysis &#8211; I\/O signals explanation). 6 lessons in 46m total course length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\">\n<a title=\"Learn more about the couse\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/electrical-design-industrial-packaging-machine\">See course details<\/a>\n<\/div>\n","protected":false},"author":17,"featured_media":8770,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[118,718],"product_tag":[164,669,719],"class_list":["post-8782","product","type-product","status-publish","has-post-thumbnail","product_cat-electrical-design","product_cat-industrial-automation","product_tag-electrical-design","product_tag-eplan","product_tag-industrial-packaging-machine","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Electrical Design of an Industrial Packaging Machine - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Master electrical design of industrial automation systems - packaging machine (wiring diagram and PLC (S7-1200) analysis - I\/O signals)\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electrical Design of an Industrial Packaging Machine - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Master electrical design of industrial automation systems - packaging machine (wiring diagram and PLC (S7-1200) analysis - I\/O signals)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-11T23:09:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/electrical-design-industrial-packaging-machine.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"563\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design\",\"name\":\"Electrical Design of an Industrial Packaging Machine - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/electrical-design-industrial-packaging-machine.jpg\",\"datePublished\":\"2021-08-21T17:16:06+00:00\",\"dateModified\":\"2021-11-11T23:09:56+00:00\",\"description\":\"Master electrical design of industrial automation systems - packaging machine (wiring diagram and PLC (S7-1200) analysis - I\\\/O signals)\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/electrical-design-industrial-packaging-machine.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/electrical-design-industrial-packaging-machine.jpg\",\"width\":1000,\"height\":563,\"caption\":\"Electrical Design of an Industrial Packaging Machine\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-industrial-packaging-machine-electrical-design#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Electrical Design of an Industrial Packaging Machine\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Electrical Design of an Industrial Packaging Machine - EEP Academy Courses","description":"Master electrical design of industrial automation systems - packaging machine (wiring diagram and PLC (S7-1200) analysis - I\/O signals)","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design","og_locale":"en_US","og_type":"article","og_title":"Electrical Design of an Industrial Packaging Machine - EEP Academy Courses","og_description":"Master electrical design of industrial automation systems - packaging machine (wiring diagram and PLC (S7-1200) analysis - I\/O signals)","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2021-11-11T23:09:56+00:00","og_image":[{"width":1000,"height":563,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/electrical-design-industrial-packaging-machine.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design","name":"Electrical Design of an Industrial Packaging Machine - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/electrical-design-industrial-packaging-machine.jpg","datePublished":"2021-08-21T17:16:06+00:00","dateModified":"2021-11-11T23:09:56+00:00","description":"Master electrical design of industrial automation systems - packaging machine (wiring diagram and PLC (S7-1200) analysis - I\/O signals)","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/electrical-design-industrial-packaging-machine.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/electrical-design-industrial-packaging-machine.jpg","width":1000,"height":563,"caption":"Electrical Design of an Industrial Packaging Machine"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-industrial-packaging-machine-electrical-design#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Electrical Design of an Industrial Packaging Machine"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/8782","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=8782"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/8770"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=8782"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=8782"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=8782"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=8782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}