{"id":9647,"date":"2021-08-26T10:49:17","date_gmt":"2021-08-26T10:49:17","guid":{"rendered":"https:\/\/electrical-engineering-portal.com\/academy\/?post_type=product&#038;p=9647"},"modified":"2021-11-11T23:57:29","modified_gmt":"2021-11-11T22:57:29","slug":"course-wiring-setting-parameters-variable-frequency-drives-vfds","status":"publish","type":"product","link":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds\/","title":{"rendered":"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs)"},"content":{"rendered":"<p>This course will teach you how to wire and set frequency converter parameters in both open and closed loop applications. The course starts with the introduction to variable frequency drives and evolution in the last few decades. The course covers<strong>\u00a0wiring diagrams of many different open-loop applications<\/strong>\u00a0you can see in the real-life world. Without any knowledge of frequency converters, you will be able to read &amp; draw a wiring diagram, connect and set the frequency converter into operation.<\/p>\n<p>The course covers closed loop applications as well. PID theory and practice as fundamental parts of automation are explained in detail.<\/p>\n<div class=\"info_box\">The last lesson covers\u00a0<strong>crane as the typical example of heavy-duty applications<\/strong>. New elements into drives operation like brake resistors, encoders, mechanical brakes, limit switches are added into wiring and analyzed.<\/div>\n<p><strong>The course will go into detail for the following key topics:<\/strong><\/p>\n<ul>\n<li>Construction of the variable frequency drive<\/li>\n<li>Real life application of VFD \u2013 Air-handling unit<\/li>\n<li>Selecting of the drive and automation logic<\/li>\n<li>Real life application of VFD \u2013 Pump system<\/li>\n<li>Wiring diagrams of different open-loop applications<\/li>\n<li>Wiring diagrams of different close-loop applications<\/li>\n<li>PID theory and practice as basic parts of automation<\/li>\n<li>VFD heavy-duty applications of crane: Crane hoisting, traveling and crane trolley<\/li>\n<\/ul>\n<p><strong>For more information and video preview, please visit the course page:<\/strong><\/p>\n<blockquote class=\"wp-embedded-content\" data-secret=\"TjvimhrRXr\"><p><a href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/variable-frequency-drives-vfds-wiring-setting-parameters\">Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs)<\/a><\/p><\/blockquote>\n<p><iframe class=\"wp-embedded-content\" sandbox=\"allow-scripts\" security=\"restricted\" style=\"position: absolute; clip: rect(1px, 1px, 1px, 1px);\" title=\"&#8220;Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs)&#8221; &#8212; EEP Academy Courses\" src=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/variable-frequency-drives-vfds-wiring-setting-parameters\/embed#?secret=rTnLjnsJ11#?secret=TjvimhrRXr\" data-secret=\"TjvimhrRXr\" width=\"600\" height=\"338\" frameborder=\"0\" marginwidth=\"0\" marginheight=\"0\" scrolling=\"no\"><\/iframe><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Learn how to wire and set frequency converter parameters in both open and close loop applications. Without any knowledge of frequency converters, you will be able to draw a wiring diagram, connect and set the frequency converter into operation. 10 lessons in 3h 8min. total course length.<\/p>\n<div class=\"single_add_to_cart_button button woo_courselink\">\n<a title=\"Learn more about the couse\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/courses\/variable-frequency-drives-vfds-wiring-setting-parameters\">See course details<\/a>\n<\/div>\n","protected":false},"author":21,"featured_media":9649,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[701,718],"product_tag":[815,813,814],"class_list":["post-9647","product","type-product","status-publish","has-post-thumbnail","product_cat-electric-motor","product_cat-industrial-automation","product_tag-close-loop","product_tag-frequency-converter","product_tag-variable-frequency-converter","first","instock","virtual","sold-individually","purchasable","product-type-course"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs) - EEP Academy Courses<\/title>\n<meta name=\"description\" content=\"Learn how to wire and set frequency converter parameters both open and close loop applications. Learn to draw a wiring diagram, connect VFD\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs) - EEP Academy Courses\" \/>\n<meta property=\"og:description\" content=\"Learn how to wire and set frequency converter parameters both open and close loop applications. Learn to draw a wiring diagram, connect VFD\" \/>\n<meta property=\"og:url\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds\" \/>\n<meta property=\"og:site_name\" content=\"EEP Academy Courses\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/eeportal\" \/>\n<meta property=\"article:modified_time\" content=\"2021-11-11T22:57:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"769\" \/>\n\t<meta property=\"og:image:height\" content=\"662\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@eeportal_com\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds\",\"name\":\"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs) - EEP Academy Courses\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg\",\"datePublished\":\"2021-08-26T10:49:17+00:00\",\"dateModified\":\"2021-11-11T22:57:29+00:00\",\"description\":\"Learn how to wire and set frequency converter parameters both open and close loop applications. Learn to draw a wiring diagram, connect VFD\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds#primaryimage\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/08\\\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg\",\"width\":769,\"height\":662,\"caption\":\"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs)\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/product\\\/course-wiring-setting-parameters-variable-frequency-drives-vfds#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Engineering Shop\",\"item\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#website\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"name\":\"EEP Academy Courses\",\"description\":\"Advanced Learning Platform For Electrical Engineers\",\"publisher\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\"},\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#organization\",\"name\":\"EEP Academy\",\"alternateName\":\"Cutting-edge hand-crafted electrical engineering courses\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"contentUrl\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/wp-content\\\/uploads\\\/2021\\\/07\\\/eep-academy-logo.png\",\"width\":533,\"height\":67,\"caption\":\"EEP Academy\"},\"image\":{\"@id\":\"https:\\\/\\\/electrical-engineering-portal.com\\\/academy\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"http:\\\/\\\/www.facebook.com\\\/eeportal\",\"https:\\\/\\\/x.com\\\/eeportal_com\",\"http:\\\/\\\/www.linkedin.com\\\/groups\\\/EEP-Electrical-Engineering-Portal-4141766\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs) - EEP Academy Courses","description":"Learn how to wire and set frequency converter parameters both open and close loop applications. Learn to draw a wiring diagram, connect VFD","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds","og_locale":"en_US","og_type":"article","og_title":"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs) - EEP Academy Courses","og_description":"Learn how to wire and set frequency converter parameters both open and close loop applications. Learn to draw a wiring diagram, connect VFD","og_url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds","og_site_name":"EEP Academy Courses","article_publisher":"http:\/\/www.facebook.com\/eeportal","article_modified_time":"2021-11-11T22:57:29+00:00","og_image":[{"width":769,"height":662,"url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@eeportal_com","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds","url":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds","name":"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs) - EEP Academy Courses","isPartOf":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website"},"primaryImageOfPage":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds#primaryimage"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds#primaryimage"},"thumbnailUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg","datePublished":"2021-08-26T10:49:17+00:00","dateModified":"2021-11-11T22:57:29+00:00","description":"Learn how to wire and set frequency converter parameters both open and close loop applications. Learn to draw a wiring diagram, connect VFD","breadcrumb":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds#primaryimage","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/08\/variable-frequency-drives-vfds-wiring-setting-parameters-course-pr.jpg","width":769,"height":662,"caption":"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs)"},{"@type":"BreadcrumbList","@id":"https:\/\/electrical-engineering-portal.com\/academy\/product\/course-wiring-setting-parameters-variable-frequency-drives-vfds#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/electrical-engineering-portal.com\/academy\/"},{"@type":"ListItem","position":2,"name":"Electrical Engineering Shop","item":"https:\/\/electrical-engineering-portal.com\/academy\/shop\/"},{"@type":"ListItem","position":3,"name":"Practical Course to Wiring and Setting Parameters of Variable Frequency Drives (VFDs)"}]},{"@type":"WebSite","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#website","url":"https:\/\/electrical-engineering-portal.com\/academy\/","name":"EEP Academy Courses","description":"Advanced Learning Platform For Electrical Engineers","publisher":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization"},"alternateName":"Cutting-edge hand-crafted electrical engineering courses","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/electrical-engineering-portal.com\/academy\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#organization","name":"EEP Academy","alternateName":"Cutting-edge hand-crafted electrical engineering courses","url":"https:\/\/electrical-engineering-portal.com\/academy\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/","url":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","contentUrl":"https:\/\/electrical-engineering-portal.com\/academy\/wp-content\/uploads\/2021\/07\/eep-academy-logo.png","width":533,"height":67,"caption":"EEP Academy"},"image":{"@id":"https:\/\/electrical-engineering-portal.com\/academy\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/eeportal","https:\/\/x.com\/eeportal_com","http:\/\/www.linkedin.com\/groups\/EEP-Electrical-Engineering-Portal-4141766"]}]}},"_links":{"self":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product\/9647","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/types\/product"}],"author":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/users\/21"}],"replies":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/comments?post=9647"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media\/9649"}],"wp:attachment":[{"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/media?parent=9647"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_brand?post=9647"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_cat?post=9647"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/electrical-engineering-portal.com\/academy\/wp-json\/wp\/v2\/product_tag?post=9647"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}