Aerodynamics of Horizontal-Axis Wind Turbines
A wind turbine is a device for extracting kinetic energy from the wind. By removing some of its kinetic energy the wind must slow down but only that mass of air which passes through the rotor disc is affected. Assuming… Read more
Dec 06, 2010 | By Edvard Csanyi
Economic advantages of power factor correction
Power supply authorities apply a tariff system which imposes penalties on the drawing of energy with a monthly average power factor lower than 0.9. The contracts applied are different from country to country and can vary also according to the… Read more
Dec 04, 2010 | By Edvard Csanyi
Forms of Separation (1) – Introduction
Standard BS EN 60439 Part 1, describes a system for classifying the various forms of separation to be provided principally for: protection against contact with live parts belonging to the adjacent functional units. limitation of the probability of initiating arc… Read more
Dec 04, 2010 | By Edvard Csanyi
ePlusMenuCAD 10 RC1 released
Today we released ePlusMenuCAD 10 RC1! Why RC1 (release candidate 1)? Simply because Help is not written yet. It will be added as soon as possible together with releasing of complete ePlusMenuCAD 10. Good thing is that CsanyiGroup (author of… Read more
Dec 03, 2010 | By Edvard Csanyi
Electrical Certificates
There is often confusion about what is commonly referred to as an “Electrical Certificate”. There are essentially 3 types of documents or certificates. Each imply different type of certification. “Electrical Installation Certificate” (EIC) is the declaration of conformity from the… Read more
Dec 02, 2010 | By Edvard Csanyi
Wind Variability
One of the most critical features of wind generation is the variability of wind. Wind speeds vary with time of day, time of year, height above ground, and location on the earth’s surface. This makes wind generators into what might… Read more
Nov 30, 2010 | By Edvard Csanyi
Danfoss – Max uptime for wind turbines
Located on top of towers that can extend 80 to 110 meters into the air, wind turbines are subjected to powerful operating forces. And because wind turbines are difficult to access for maintenance and repair, reliable monitoring and control components,… Read more
Nov 29, 2010 | By Edvard Csanyi
ABB invests in renewable energy company
Zurich, Switzerland, November 24, 2010 – ABB, the global power and automation technology group, announced today it has invested about $13 million in Aquamarine Power, a Scottish company that has developed technology to convert energy captured from waves near shore… Read more
Nov 29, 2010 | By Edvard Csanyi
Transformer Cooling Classes
Since no transformer is truly an “ideal” transformer, each will incur a certain amount of energy loss, mainly that which is converted to heat. Methods of removing this heat can depend on the application, the size of the unit, and… Read more
Nov 28, 2010 | By Edvard Csanyi
Should You Invest in Solar Power?
Solar power is quickly gaining popularity all over the globe. It is growing at a rate of 2% per year, and if the figures continue to grow, solar energy will be the preferred source of energy worldwide. Most modern nations… Read more
Nov 27, 2010 | By Edvard Csanyi
Electrical Power System Overcurrents
Electrical power systems must be designed to serve a variety of loads safely and reliably. Effective control of short-circuit current, or fault current as it is commonly called, is a major consideration when designing coordinated power system protection. In order… Read more
Nov 27, 2010 | By Edvard Csanyi
Megger Tests
The insulation resistance meter test method for determining the condition of electrical insulation has been widely used for many years as a general nondestructive test method. A serious limitation of this test is that its operating voltage of 500 to… Read more
Nov 26, 2010 | By Edvard Csanyi
Harmonic Distortion
Harmonic distortion is caused by nonlinear devices in the power system. A nonlinear device is one in which the current is not proportional to the applied voltage. Figure 1 illustrates this concept by the case of a sinusoidal voltage applied… Read more
Nov 23, 2010 | By Edvard Csanyi
Battery monitoring and maintenance guidelines
Battery monitoring has become a very popular topic, and many companies have either purchased equipment or are in the process of evaluating these systems. This article discusses why monitoring is important, and what parameters must be monitored. A brief explanation… Read more
Nov 21, 2010 | By Edvard Csanyi
The Need for Reactive Power Compensation
Except in a very few special situations, electrical energy is generated, transmitted, distributed, and utilized as alternating current (AC). However, alternating current has several distinct disadvantages. One of these is the necessity of reactive power that needs to be supplied… Read more
Nov 19, 2010 | By Edvard Csanyi