Oil-Filled, Inert-Gas System
A positive seal of the transformer oil may be provided by an inert-gas system. Here, the tank is slightly pressurized by an inert gas such as nitrogen. The main tank gas space above the oil is provided with a pressure… Read more
Nov 08, 2010 | By Edvard Csanyi
What is the cost of electricity?
Electrification in the early 20th century dramatically improved productivity and increased the well-being of the industrialized world. No longer a luxury – now a necessity – electricity powers the machinery, the computers, the health-care systems, and the entertainment of modern… Read more
Nov 02, 2010 | By Edvard Csanyi
Short-Circuit Electrical Currents
A short circuit is one of the major incidents affecting electrical systems. The consequences are often serious, if not dramatic: Short circuit disturbs the system environment around the fault point by causing a sudden drop in voltage, It requires a… Read more
Oct 28, 2010 | By Edvard Csanyi
Aluminum vs. Copper: Conductors in Low Voltage Dry Type Transformers
In North America, aluminum is the predominant choice of winding material for low-voltage, dry-type transformers larger than 15 kilovolt-amperes(kVA). In most other areas of the world, copper is the predominant winding material. The primary reason for choosing aluminum windings is… Read more
Oct 27, 2010 | By Edvard Csanyi
Generating Power In The Future – Solar Wind Power
As the world discovers new ways to meet its growing energy needs, energy generated from Sun, which is better known as solar power and energy generated from wind called the wind power are being considered as a means of generating… Read more
Oct 24, 2010 | By Edvard Csanyi
Power System Stability
Power system stability is the ability of the system, for a given initial operating condition, to regain a normal state of equilibrium after being subjected to a disturbance. Stability is a condition of equilibrium between opposing forces; instability results when… Read more
Oct 23, 2010 | By Edvard Csanyi
Types of Underground Lines
There are two methods of installing underground lines. In the first method, underground raceway systems (ducts) are installed below grade and then cable is pulled through them. Ducts may or may not be provided with concrete encasement. The second method… Read more
Oct 22, 2010 | By Edvard Csanyi
Introducing EEP
Hi to everyone, we are working hard on EEP, which is by the way supported by CsanyiGroup – also electrical engineering portal. Content will be similar like CsanyiGroup’s, but with much more style and funcionality. So far, we will first… Read more
Sep 16, 2010 | By Edvard Csanyi
Comparison Between Vacuum and SF6 Circuit Breaker
Until recently oil circuit breakers were used in large numbers for Medium voltage Distribution system in many medium voltage switchgears. There are number of disadvantages of using oil as quenching media in circuit breakers. Flammability and high maintenance cost are… Read more
Sep 05, 2010 | By Edvard Csanyi
The Best Applications For Variable Frequency Drives (VFDs)
Advances The most commonly used motor in building HVAC applications is the three-phase, induction motor, although some smaller applications may use a single-phase induction motor. VFDs can be applied to both. While VFD controllers can be used with a range… Read more
Sep 03, 2010 | By Edvard Csanyi