Edvard Csanyi
1765 awesome technical articles
Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.
I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.
Biography: https://electrical-engineering-portal.com/edvard-csanyi
Five power quality devices that every commercial plant must have installed
Nowadays everybody speaks about power quality. For many reasons, I would say. Electrical energy is now polluted more than ever, and consumers are more sensitive to power disruptions and fluctuations than a small flower to the stronger wind. But, it… Read more
Apr 20, 2020 | By Edvard Csanyi
Practical tips for the protection of generators and power transformers
There are usually several ways of protecting HV/MV generators and transformers. It should be noted that one protection relay is often used for several functions, for example, an overcurrent relay can be used for both overcurrent and earth fault protection…....
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Apr 17, 2020 | By Edvard Csanyi
Switching devices you are likely to spot in every medium voltage switchgear
Up to and including 52 kV voltage range is generally referred to as “medium voltage”. This technical article shed some light on a few devices you are likely to spot in most of the medium voltage switchgear. But, before diving…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Apr 13, 2020 | By Edvard Csanyi
The essentials of power systems: Relay protection and communication systems
First, I would like to make a note that there are many essentials when we speak about power systems in general. The main relay protection functions (overcurrent, directional, differential, distance, etc.) and network communication systems (SCADA, RTUs, digital and analog… Read more
Apr 06, 2020 | By Edvard Csanyi
Civil engineering in installation of substation buildings and switchboard rooms
What is the civil engineering of substation? The civil engineering includes a large quantity of information and details for the structural drawings required to design switchgear installations. The structural drawings are the basis for producing the structural design plans (foundation,… Read more
Apr 01, 2020 | By Edvard Csanyi
Six less known phenomena that can cause disturbance in electrical installations
In addition to the known phenomena of lightning and switching, numerous new sources, in particular power converters, can cause disturbance in installations. This disturbance, which is generated by the installation itself or carried by the system from external sources or… Read more
Mar 30, 2020 | By Edvard Csanyi
AC and DC facilities in electrical station services of major power plant types
In a power plant, the electrical station services (abbreviated to SS in the following) consist of all the DC facilities from 24 to 220 V and AC facilities up to about 20 kV for controlling and supplying power to the…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Mar 23, 2020 | By Edvard Csanyi
The art of determining the right cross-section of low voltage conductors
To be clear at the beginning of this article, determining the cross-section of conductors and cables is, for sure, not the most exciting part of electrical design. There are much more challenging and more exciting parts than staring at endless… Read more
Mar 16, 2020 | By Edvard Csanyi
Best relay protection practices applied to shunt reactors, capacitors, SVCs and STATCOMs
This technical article explains the protection practices applied to shunt reactors and capacitors as well as to static var compensators (SVCs) and static compensators (STATCOMs). Dry-type and oil-immersed reactors usually use overcurrent, negative sequence, percentage differential, or impedance relays depending… Read more
Mar 11, 2020 | By Edvard Csanyi
What are the primary substation feeders? How to analyze their arrangements?
A feeder carries energy to a substation or bus or to several loads. The several substation feeder arrangements are discussed in this technical article. Feeder may connect two substation buses in parallel to provide stiffness or service continuity for the… Read more
Mar 09, 2020 | By Edvard Csanyi
An overview of transformer connections and diagrams in the electric power system
Power transformers are used extensively by traditional electric utility companies, power plants, and industrial plants. This technical article summarizes the basic types, connections, and diagrams of transformers needed for analyzing the electrical transmission and distribution systems. Analyzing electric power systems,…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Mar 05, 2020 | By Edvard Csanyi
Five actions to achieve excellent energy savings in old electrical installations
Not all existing electrical installations lack energy efficiency, but most of them do. Especially if they were built 15-20 years ago and older. Although it is generally acknowledged that substantial energy savings are possible in most existing installations, the process… Read more
Mar 04, 2020 | By Edvard Csanyi
Primary substations and bus layouts in the distribution system of an industrial plant
The primary distribution system of an industrial plant is generally the higher voltage portion of the system, starting with the purchased-power service and including generators, switching equipment, circuits, and all transformers with secondary voltages higher than 600 V. This technical… Read more
Mar 02, 2020 | By Edvard Csanyi
Design tips for medium voltage systems and switchgear in power substations
Medium voltage networks are networks with rated voltages of over 1kV and up to 36kV. Medium voltage switchgear is used in transformer substations and switching substations, and in secondary unit substations and customer substations (in public utility networks only). This… Read more
Feb 26, 2020 | By Edvard Csanyi
The art of designing the auxiliary system of a power plant
Power plant auxiliary system is usually pretty complicated and consists of dozen of motors, transformers, capacitor banks, variable frequency drives, PLCs, and other electrical devices. Therefore, protection relaying cannot be simple, and it requires special attention for each component of… Read more
Feb 24, 2020 | By Edvard Csanyi

