Think Of These Things When Purchasing SCADA Software Package
While performance and efficiency of the SCADA software package with the current plant is important, the package you will purchase should be easily upgradeable to handle future requirement. The system must be easily modifiable as the requirement change and expandable… Read more
Jun 13, 2016 | By Edvard Csanyi
6 Adjustable Tripping Settings of a Circuit Breaker You MUST Understand
There are (at least) six basic adjustable tripping settings (functions) you really should understand in order to fully understand how circuit breaker actually works. All these adjustable functions actually shape the time-current curve of a circuit breaker and allows proper… Read more
Jun 10, 2016 | By Edvard Csanyi
Where and Why Do We Use Grounding Transformer (zig-zag, grounded wye-delta)
Grounding transformers are sometimes used on distribution systems. A grounding transformer provides a source for zero sequence current. Sometimes they are used to convert a 3-wire, ungrounded circuit into a 4-wire, grounded circuit. Figure 1 (see below) shows the two most common grounding transformers. The… Read more
Jun 08, 2016 | By Edvard Csanyi
Where Do We Use Arc Suppression Coil (Petersen Coil)?
The arc suppression coil (ASC), also known as Petersen coil, is used to compensate the capacitive earth fault currents supplied by outgoing feeders at a substation. The compensation can be either centralized or distributed. With the centralized design, one ASC… Read more
Jun 06, 2016 | By Edvard Csanyi
Few Tips For Correct Protection Against Indirect Contact In TT System
An earth fault in a TT system originates the circuit represented in Figure 1. The fault current flows through the secondary winding of the transformer, the line conductor, the fault resistance, the protective conductor, and the earth electrode resistances (RA,… Read more
Jun 03, 2016 | By Edvard Csanyi
Power distribution configurations with three 3-phase hot power lines
Power leaves the substation on three, three-phase “hot” power lines that are strung adjacent to highways or along local roads to points of use. All three phases share a single neutral line and have the same voltage, but they are… Read more
Jun 01, 2016 | By Edvard Csanyi
Equipment Used To Implement Automatic Transfer System (ATS)
Although the basic operational requirements of any automatic transfer system are as given in this technical article, the equipment which is used to implement the automatic transfer system can vary. The following is a list of commonly encountered variations regarding… Read more
Jun 01, 2016 | By Edvard Csanyi
Tips For Successful Energy Efficiency Of Centrifugal Water Chillers
Centrifugal water chillers comprise a significant portion of industrial and large commercial electrical load. These machines are efficient, typically producing a cooling effect two-to-three times greater than the required energy input. Centrifugal water systems were the focus of cholorfluorocarbon (CFC)… Read more
May 30, 2016 | By Edvard Csanyi
What would be the best solution for urban supply networks – AIS or GIS system?
This technical analysis was carried out by ABB to show that for urban supply networks the combination of HV gas insulated switchgear – GIS (due to their compactness and flexibility) and HV cable has important advantages over systems with air insulated… Read more
May 23, 2016 | By Edvard Csanyi
Shielding and Grounding Practices for Control Cables in EHV Substations
For several years, the increased application of solid-state devices for protective relaying and control and for electronic equipment, such as audio tones, carrier and microwave equipment, event recorders, and supervisory control equipment, in EHV substations has resulted in many equipment… Read more
May 20, 2016 | By Edvard Csanyi
Do’s and don’ts when measuring insulation resistance of a transformer
This test is performed at or above rated voltage to determine if there are low resistance paths to ground or between winding to winding as a result of winding insulation deterioration. The test measurement values are affected by variables such… Read more
May 18, 2016 | By Edvard Csanyi
Using digital multimeter for testing the charging system of your car
To be honest with you, this article is about testing the car charging system and it isn’t applicable on new Tesla Model III or new BMW 7-series. As you can already guess from the title itself, all testings described below… Read more
May 16, 2016 | By Edvard Csanyi
Why Good Care Of Overcurrent Protective Devices Really Matter
Whether in the design or maintenance of an electrical system, hazards exist if the proper overcurrent protective devices are not selected and applied. Circuit breakers and other electrical equipment also must be maintained and serviced regularly to ensure that they will… Read more
May 13, 2016 | By Edvard Csanyi
General Requirements For Operation and Maintenance Of Battery Cells
Primary battery cells cannot be recharged and once their energy is depleted they should be disposed off in the manner recommended by the manufacturer. The cells should be examined occasionally during their life for signs of leakage or physical deformation…. Read more
May 11, 2016 | By Edvard Csanyi
A few tips on how to select contactors for use in direct on line starters
Contactors for use in direct on line starters (DOL) are normally selected by their AC3 rating, that is the switching on of a cage type induction motor and switching off the supply to the motor after the motor has run… Read more
May 09, 2016 | By Edvard Csanyi