Author: Edvard Csanyi (Technical Articles)

Edvard Csanyi

1769 awesome technical articles

Edvard Csanyi - Author at EEP-Electrical Engineering Portal

Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.

I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.

Biography: https://electrical-engineering-portal.com/edvard-csanyi

Electrical Lectures

2 approaches to analyse and solve series parallel networks

A firm understanding of the basic principles associated with series and parallel circuits is a sufficient background to begin an investigation of any single-source DC network having a combination of series and parallel elements or branches. In general, series parallel networks are… Read more

Jan 01, 2016 | By

2 approaches to analyse and solve series parallel networks
Energy and Power

LV Surge Arresters In Action Against Lightning

The site consists of offices (computer hardware, lighting and heating unit), a security post (fire alarm, burglar alarm, access control, video surveillance) and three buildings for the manufacturing process on 10 hectares in the Avignon region of France (probability of… Read more

Dec 29, 2015 | By

LV Surge Arresters In Action Against Lightning
Energy and Power

Smart Ways To Cut Down The Influence Of Harmonics

There are three possible ways of suppressing or at least reducing the influence of harmonics. The fourth way is a special case. Contents: Reducing generated harmonic currents Modifying the installation Filtering Special case – circuit breakers Generated harmonic currents can be reduced… Read more

Dec 28, 2015 | By

3 Ways To Suppress (Or Reduce) The Influence Of Harmonics
Energy and Power

The Basics Of Circuit Breaker Tripping Units

The main objective of circuit breaker tripping units and protective functions in general is to detect faults and to selectively isolate faulted parts of the system. It must also permit short clearance times to limit the fault power and the… Read more

Dec 21, 2015 | By

The Basics Of Circuit Breaker Tripping Units
Energy and Power

Learn To Interpret Single Line Diagram (SLD)

We usually depict the electrical distribution system by a graphic representation called a single line diagram (SLD). A single line can show all or part of a system. It is very versatile and comprehensive because it can depict very simple… Read more

Dec 19, 2015 | By

Learn To Interpret Single Line Diagram (SLD)
Energy and Power

The basics of primary medium voltage switchgear

Primary medium voltage switchgear represents an important part within the primary distribution substation functionality. The switchgear works as a connection node between the outgoing distribution feeders and the in-feeding power transformers. The most common construction with the switchgear is an… Read more

Dec 14, 2015 | By

Basics Of Primary Medium Voltage Switchgear