Author: Edvard Csanyi (Technical Articles)

Edvard Csanyi

1754 awesome technical articles

Edvard Csanyi - Author at EEP-Electrical Engineering Portal

Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.

I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.

Biography: https://electrical-engineering-portal.com/edvard-csanyi

High Voltage

Conductor Types Used For Overhead Lines

The international standards covering most conductor types for overhead lines are IEC 61089 (which supersedes IEC 207, 208, 209 and 210) and EN 50182 and 50183 (see Table 1). For 36 kV transmission and above both aluminium conductor steel reinforced… Read more

Apr 20, 2013 | By

Conductor Types Used For Overhead Lines
Energy and Power

Using AC switchgear in DC applications

Switchgear designed for alternating current can carry at least the same rated continuous operational DC current. With direct current the skin effect in the circuits disappears and none of the specific effects associated with alternating currents such as hysteresis or… Read more

Apr 19, 2013 | By

Using AC switchgear in DC applications
Lighting

Visual Tasks of Typical Living Room Lighting

Most living rooms require flexible lighting design solutions because they serve a broad variety of changing functions. The lighting in a typical living room should comfortably serve small group conversation, larger social gatherings that include casual eating and drinking, and… Read more

Apr 17, 2013 | By

Visual Tasks of Typical Living Room Lighting
Energy and Power

Grounding systems and their 3-letter classification

Low voltage systems supplying to consumer premises are predominantly solidly grounded. Protective ground connection to consumer premises (or extending the supply system ground to consumer premises) is however done in different ways. The common system categories are defined below using a 3-letter… Read more

Apr 12, 2013 | By

Grounding systems and their 3-letter classification
Power Substation

Responding to Cyber Intrusion in SCADA System

Continued from technical article: Detecting Cyber Intrusion in SCADA System The “three R’s” of the response to cyber intrusion are: Recording, Reporting, and Restoring. Theoretically, it would be desirable to record all data communications into and out of all substation… Read more

Apr 08, 2013 | By

Responding to Cyber Intrusion in SCADA System
Energy and Power

Detecting Cyber Intrusion in SCADA System

One of the axioms of cyber security is that although it is extremely important to try to prevent intrusions into one’s systems and databases, it is essential that intrusions be detected if they do occur. One of the axioms of… Read more

Apr 06, 2013 | By

Detecting Cyber Intrusion in SCADA System
Industrial Automation

Benefits and Potential Drawbacks of VSDs

VSDs (Variable Speed Drives) offer several benefits, some of which are relatively easy to quantify, and others of which are less tangible, but there are some potential drawbacks, which must be avoided. With rotodynamic pump installations, savings of between 30%… Read more

Apr 03, 2013 | By

Benefits and Potential Drawbacks of VSDs
Power Substation

Active fire protection measures in power substation

Active fire protection measures are automatic fire protection measures that warn occupants of the existence of fire, and extinguish or control the fire. These measures are designed to automatically extinguish or control a fire at its earliest stage, without risking… Read more

Apr 01, 2013 | By

Active fire protection measures in power substation
Wind Power

Wind Energy End-Use Applications

Wind energy markets can be classified based on the end-use application of the technology. Wind energy projects are common for off-grid applications. However, the largest market potential for wind energy projects is with on-grid (or grid-connected) applications. Historically, wind energy… Read more

Mar 30, 2013 | By

Wind Energy End-Use Applications
Electric Motor

Induction motor startup and losses calculation

The main objectives while starting an induction motor are: To handle high-starting current To achieve high-starting torque. As we know, rotor resistance determines starting torque. Usually, this rotor resistance is small, giving small starting torque, but good running conditions. So, the squirrel-cage motor… Read more

Mar 25, 2013 | By

Induction motor startup and losses calculation


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.