Author: Asif Eqbal (Technical Articles)

Asif Eqbal

25 awesome technical articles

Asif Eqbal - Author at EEP-Electrical Engineering Portal

Bachelor of Engineering in Electrical & Electronics engineering, from Manipal University, (Karnataka), India in 2006. Presently involved in the design of EHV outdoor substation and coal fired thermal power plants for more than seven years. Motto of joining EEP as a contributor is to share my little engineering experience and help the budding engineers in bridging the conspicuous gap between academics and Industrial practice. “If you have knowledge, let others light their candles with it, so that people who are genuinely interested in helping one another develop new capacities for action; it is about creating timeless learning processes".

Biography:

Electrical Lectures

Capacitor Banks In Power System (part four)

Let us consider that there is a captive diesel generator (DG) the rating of which is specified as 1000kVA and PF 0.85. Rating in kVA specifies the maximum current the alternator can deliver at the system voltage. In the previous… Read more

Mar 27, 2012 | By

Alternator capability curve
Electrical Lectures

Capacitor Banks In Power System (part three)

Continued from part two – Capacitor Banks In Power System (part two) Capacitor units shall be suitable for continuous operation at an RMS current of 1.30 times the current that occurs at rated sinusoidal voltage and rated frequency, excluding transients…. Read more

Mar 03, 2012 | By

Low Voltage Power Capacitor
Electrical Lectures

Capacitor Banks In Power System (part two)

Continued from part one – Capacitor Banks In Power System (part one) It should be noted that in an inductance the current lags the voltage by 90 degrees and in a capacitor the current leads the voltage by 90 degrees…. Read more

Mar 01, 2012 | By

Capacitor banks in low voltage switchgear
Electrical Lectures

Capacitor banks in power system (part 1)

When a charge is delivered to a conductor its potential is raised in proportion to the quantity of charge given to it. At a particular potential a conductor can hold a given amount of charge. Capacitance is the term to… Read more

Feb 27, 2012 | By

Capacitor banks in power system (part 1)
Electrical Lectures

About Permeability And Permitivity

The strength of electric field or electrostatic force strength or intensity of field (all synonymous terms) is measured & expressed in terms of force experienced by unit positive charge placed in sphere of influence of another source charge, which has… Read more

Feb 01, 2012 | By

Electric field intensity - closed path denoted by ABCD
Energy and Power

Anti Pumping And Lockout Relays

What is ANSI code for Antipumping relay? ANSI codes 94 or even 52 can be used. Relays can be divided into six functional categories shown below: Detect defective lines, defective apparatus, or other dangerous or intolerable conditions. These relays generally… Read more

Jan 23, 2012 | By

Anti-pumping relay - Powell