Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Author: Bipul Raman (Technical Articles)

Bipul Raman

13 awesome technical articles

Bipul Raman - Author at EEP-Electrical Engineering Portal

Bipul Raman (@BipulRaman) is a Technology Enthusiast, Programmer and Blogger. Read more at : https://www.bipul.in

Biography: https://www.bipul.in

Energy and Power

Overview of Single Phase Induction Type Energy Meter

Single phase induction type energy meter is also popularly known as watt-hour meter. This name is given to it. This article is only focused about its constructional features and its working. Induction type energy meter essentially consists of following components:… Read more

Sep 28, 2012 | By

Single-phase induction kilowatt hour meter
Energy and Power

220V DC system at thermal power station

The 220V DC system supplies direct current as source of operating power for control, signaling, relays, tripping and closing of switchgears, emergency motors of most important auxiliary systems. Under normal conditions of station generation, the storage battery units are kept… Read more

Feb 15, 2012 | By

220V DC system at thermal power station
High Voltage

Protection Of Generators And Transformers

As Generators and transformers are major components of a power system, so it is quite necessary to take all the preventive measures for the protection of transformers and generators. These are the following ways (ANSI codes) we use to protect… Read more

Feb 11, 2012 | By

Protection of generators and transformers (Siprotec numerical protection relays)
Energy and Power

Moving Iron Instruments – Voltmeter and Ammeter

Moving-iron instruments are generally used to measure alternating voltages and currents. In moving-iron instruments the movable system consists of one or more pieces of specially-shaped soft iron, which are so pivoted as to be acted upon by the magnetic field… Read more

Nov 13, 2011 | By

Analog ammeter and voltmeter designed to measure a.c. current and a.c. voltage
Biomass Energy

Biodiesel – Myths and Facts

Few facts you most probably know already, but never the less to mention: A clean burning alternative fuel, produced from domestic, renewable resources such as plant oils, animal fats, used cooking oil and even new sources such as algae. Contains… Read more

Nov 05, 2011 | By

Biodiesel cycle
Cables

Understanding Underground Electric Transmission Cables

Underground cables have different technical requirements than overhead lines and have different environmental impacts. Due to their different physical, environmental, and construction needs, underground transmission generally costs more and may be more complicated to construct than overhead lines. The design… Read more

Sep 21, 2011 | By

Underground XLPE cables left to right: 345 kV, 138 kV, 69 kV, and distribution
Energy and Power

Virus-Powered Battery

Engineers at MIT (Massachusetts Institute of Technology) have figured out a way to deal with virus that is better than just killing them: they’re putting them to work. The researchers have developed a new technique wherein a key component of… Read more

Sep 16, 2011 | By

An array of microbattery electrodes


EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.