Inside the power grid collapse and measures for preventing voltage instability and loss
The problem of voltage stability and voltage collapse has been studied and investigated for some decades now. A number of incidents have appeared around the world and some intensive work has been made to better understand the phenomena and to… Read more
Aug 15, 2022 | By Edvard Csanyi
Breaker failure protection applications of modern numerical distance relays
Modern numerical distance relays are equipped with a wide range of protection features, including overcurrent, overvoltage, undervoltage, underfrequency, overfrequency, breaker failure, synchronism check, power swing blocking and tripping, pilot protection schemes, digital relay-to-relay communications capability, logic programmability, and sophisticated math… Read more
Aug 01, 2022 | By Edvard Csanyi
Key points on how to design a fault-tolerant and reliable facility distribution system
Nowadays, power system reliability is more important than ever. Regardless of how reliable the individual power-system components may be, some sort of power-system redundancy is necessary to attain high levels of power-system reliability, with the ultimate aim being 24 hour/day… Read more
Jul 18, 2022 | By Edvard Csanyi
The most often low-voltage switchboard supply schematics implemented on-site
This technical article is dedicated to several different low voltage switchboard supply schematics often installed on-site. First, we shall look at the several standard LV switchboard supply schematics (network supply only), then supply schematics for switchboards backed up by generators,… Read more
Jul 04, 2022 | By Edvard Csanyi
Shunt reactor fundamentals: Connections in the substation, switching and protection practice
Due to changes in the generation and load structure, the transmission and distribution networks are always encountering new challenges. Many regions, for example, are gradually changing their power networks, such as expanding generation, joining local/regional grids, and moving from overhead… Read more
Jun 20, 2022 | By Edvard Csanyi
LV/MV power substation equipment and wiring requirements you must understand
The space requirements of a power substation depend on the equipment to be housed, and on whether a new building can be erected for it or it has to be fitted into an existing building. In the case of an… Read more
Jun 06, 2022 | By Edvard Csanyi
Main and auxiliary circuit diagrams of switching pole-changing three-phase motors
This technical article is dedicated to the main and auxiliary circuit diagrams of switching three-phase motors. We’ll now discuss a little more complicated schematics than the previous article. We’ll cover seven schematics of switching pole-changing three-phase induction motors with one…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
May 23, 2022 | By Edvard Csanyi
Main and auxiliary circuit diagrams of switching three-phase motors via contactor and directly
This technical article will try to shed some light on the main and auxiliary circuit diagrams of switching three-phase motors via contactor and switching directly. We’ll cover some fundamental schematics with an old-school explanations and logics on how they work…. Read more
May 16, 2022 | By Edvard Csanyi
The most common type tests required for medium and high voltage switchgear
Let me put the definition of switchgear type tests this way. A switchgear MUST withstand voltage in normal and abnormal conditions and to carry varying load currents during its lifetime. A switchgear MUST be able to clear faults occurring due…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
May 02, 2022 | By Edvard Csanyi
The essentials of standby power systems you SHOULD install before the blackout happens
The cost of a standby power system for a business can be pretty high, so it’s essential to weigh all of your options before committing to a piece of equipment. The direct and indirect costs must be clearly and unequivocally…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Apr 25, 2022 | By Edvard Csanyi
How to handle overvoltages before any damage is done? Surge protection in a nutshell.
Prevention is better than cure, we all know this, and this is true not only for people, but also for the health of your electrical and electronic components and equipment. Smart and cost-effective strategies demand an investment in surge protection…. Read more
Apr 11, 2022 | By Edvard Csanyi
12 essential parameters required for rating large generators
When specifying generators, the first thing that comes to mind is a rating. The machine’s rating is a set of parameters that, simply speaking in engineering terms, describe the generator. These values indicate the generator’s available power output as well…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Mar 28, 2022 | By Edvard Csanyi
Medium voltage switchgear: Important design considerations and applications
This technical article explains various aspects of the application of medium voltage switchgear and highlights the considerations for the selection of suitable circuit breakers for different applications. Medium voltage switchgear, commonly known as MV switchgear, play a significant role in…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Mar 14, 2022 | By Edvard Csanyi
The essentials of necessary auxiliary relays in tripping and control applications
Tripping circuit breakers and operating alarms in control and protection applications usually require more than one relay contact. Tripping relays are used to multiply the number of contacts available, provide isolation between the source and system operating element and meet… Read more
Feb 28, 2022 | By Edvard Csanyi
Emergency breaking, stop and isolation intended to eliminate danger as quickly as possible
As their name indicates, emergency operations are intended to eliminate, as quickly as possible, a danger that occurs unexpectedly. The emergency break is designed to cut off the electrical power, whereas the emergency stop takes account of the danger of… Read more
Feb 14, 2022 | By Edvard Csanyi