Author: Edvard Csanyi (Technical Articles)

Edvard Csanyi

1768 awesome technical articles

Edvard Csanyi - Author at EEP-Electrical Engineering Portal

Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.

I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.

Biography: https://electrical-engineering-portal.com/edvard-csanyi

Protection

Distance Relays

Distance relays respond to the voltage and current, i.e., the impedance, at the relay location. The impedance per mile is fairly constant so these relays respond to the distance between the relay location and the fault location. As the power… Read more

Nov 12, 2010 | By

Distance relays
High Voltage

Gas-Insulated Substations – GIS

A gas-insulated substation (GIS) uses a superior dielectric gas, SF6, at moderate pressure for phase-tophase and phase-to-ground insulation. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in SF6 gas inside grounded metal enclosures. The… Read more

Nov 10, 2010 | By

Gas-Insulated Substations - GIS
Lighting

Emergency lights

Indepandant emergency supply Many buildings must have some form of emergency lighting to come on if the electric supply to the ordinary lights fails. BS 5266: Emergency lighting, BS EN 1838, BS 5266–7: Lighting applications. Emergency lighting are the codes… Read more

Nov 10, 2010 | By

Emergency lights
Transformers

Oil-Filled, Inert-Gas System

A positive seal of the transformer oil may be provided by an inert-gas system. Here, the tank is slightly pressurized by an inert gas such as nitrogen. The main tank gas space above the oil is provided with a pressure… Read more

Nov 08, 2010 | By

Oil transformer
Energy and Power

What is the cost of electricity?

Electrification in the early 20th century dramatically improved productivity and increased the well-being of the industrialized world. No longer a luxury – now a necessity – electricity powers the machinery, the computers, the health-care systems, and the entertainment of modern… Read more

Nov 02, 2010 | By

Cost Of Electricity
Energy and Power

Short-Circuit Electrical Currents

A short circuit is one of the major incidents affecting electrical systems. The consequences are often serious, if not dramatic: Short circuit disturbs the system environment around the fault point by causing a sudden drop in voltage, It requires a… Read more

Oct 28, 2010 | By

Short-circuit current diagram
Energy and Power

Power System Stability

Power system stability is the ability of the system, for a given initial operating condition, to regain a normal state of equilibrium after being subjected to a disturbance. Stability is a condition of equilibrium between opposing forces; instability results when… Read more

Oct 23, 2010 | By

power-system-stability-2
Cables

Types of Underground Lines

There are two methods of installing underground lines. In the first method, underground raceway systems (ducts) are installed below grade and then cable is pulled through them. Ducts may or may not be provided with concrete encasement. The second method… Read more

Oct 22, 2010 | By

News

Introducing EEP

Hi to everyone, we are working hard on EEP, which is by the way supported by CsanyiGroup – also electrical engineering portal. Content will be similar like CsanyiGroup’s, but with much more style and funcionality. So far, we will first… Read more

Sep 16, 2010 | By

EEP - Electrical Engineering Portal
Medium Voltage

Comparison Between Vacuum and SF6 Circuit Breaker

Until recently oil circuit breakers were used in large numbers for Medium voltage Distribution system in many medium voltage switchgears. There are number of disadvantages of using oil as quenching media in circuit breakers. Flammability and high maintenance cost are… Read more

Sep 05, 2010 | By

Comparison Between Vacuum and SF6 Circuit Breaker