Four abnormal operating conditions of a generator that could shut down the power plant
To be clear, the generator is very simple in construction and yet very complicated in operation rotating equipment. In a power plant, a generator cannot be considered in isolation because of a very large number of other equipment connected to…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Sep 06, 2021 | By Edvard Csanyi
Practical design knowledge in harmonics distortion and power factor correction (PFC)
Nowadays, if you do not consider harmonics distortion when designing a new network, you missed the whole point of the network design. Yes, really. The sooner you realize that harmonics problems are on the rise, the better. Modern power networks… Read more
Aug 30, 2021 | By Edvard Csanyi
A quick reminder to substation transformer basics and safety precautions, dos and don’ts
Let us remind ourselves of the basics of substation transformer parts, their operation principles, and do’s and don’ts for safety measures and precautions. For novice substation engineers it’s important to recognize every single detail of a transformer and later to… Read more
Aug 16, 2021 | By Edvard Csanyi
Isolation power solutions for ultimate power availability, efficiency and safety in hospitals
Things are changing fast, really fast. Technology we used a few years ago is now obsolete, and if you take a look for a second – it’s always about power availability, efficiency, and safety. This technical article deals with Schneider… Read more
Aug 04, 2021 | By Edvard Csanyi
Special measures needed for switching MV capacitor banks and filter circuits
Switching of medium voltage capacitor banks and filter circuits poses special demands on the circuit-breaker. Potentially critical impacts are the inrush current and the stress of the recovery voltage. This technical article deals with the requirements of capacitor banks without… Read more
Aug 02, 2021 | By Edvard Csanyi
The magic that isolation transformer uses to suppress transients and noise
Transformers are not perfect. Transients and noise (radio-frequency and low-level spikes) normally pass through transformers, not only by way of the magnetic lines of flux between the primary and the secondary windings but through resistive and capacitive paths between the… Read more
Jul 21, 2021 | By Edvard Csanyi
Six methods to control the flow of harmonic currents and decrease harmonic distortion limits
The first technique to control harmonic-related problems in the industry involved substantial use of single-tuned filters to offer a low-impedance path to harmonic currents. Interestingly, it is not difficult to find harmonic-producing loads in the megavolt-ampere range in the industry… Read more
Jul 19, 2021 | By Edvard Csanyi
Uprating and expanding existing power substations (good practice and recommendations)
All actions involving substation construction require heavy planning. This is especially true of a program of substation uprating or expansion. The trend is toward the assessment of existing substations and individual equipment to develop a predictive maintenance and substation life…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Jul 05, 2021 | By Edvard Csanyi
The difference in how series and shunt capacitors regulate the voltage and reactive power flows
At a casual look, a capacitor seems to be a pretty boring and unsophisticated device, that is, two metal plates separated by a dielectric insulating material. Couldn’t be simpler than that. The capacitor has no moving parts but instead functions… Read more
Jun 21, 2021 | By Edvard Csanyi
Schematics and docs needed for communication systems of substation protective relaying system
Communication systems of electric utilities have become increasingly critical to electric system protection, operation, and maintenance. For fast tripping and clearing of system faults, communication-aided relaying has become a common protection scheme, particularly in line protection. Control centers depend on…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Jun 09, 2021 | By Edvard Csanyi
Parallel switching phenomenon when MV/HV circuit breakers interrupt a shared fault current
Parallel switching occurs when two or more circuit-breakers are tripped to interrupt a shared fault current. This is typically the case for such bus arrangements as a double breaker, breaker-and-a-half, breaker-and-a-third, and ring buses. Ideally, all of the circuit-breakers should… Read more
Jun 07, 2021 | By Edvard Csanyi
Distribution earthing systems in LV/MV networks (design instructions and precautions)
The electrical earthing system is designed to provide safe and correct operation of the network under normal, earth fault, and transient conditions. During earth fault conditions, large fault currents may flow via the general mass of the earth en route… Read more
Jun 02, 2021 | By Edvard Csanyi
The essentials of overcurrent protection you are not allowed to forget (types and principles)
Relay protection is nowadays completely digitalized and very sophisticated; there is no doubt about that. But, do electrical engineers really understand what they do when setting parameters and navigate through endless menus on a relay? Most engineers do know, of… Read more
May 24, 2021 | By Edvard Csanyi
The most common failure modes of electrical equipment in distribution systems
Each piece of electrical equipment on a distribution system has a probability of failing. When first installed, a piece of equipment can fail due to poor manufacturing, damage during shipping, or improper installation. Healthy equipment can fail due to extreme… Read more
May 10, 2021 | By Edvard Csanyi
Dos, don’ts and precautions in wiring cables and conductors inside low-voltage switchboard
To be clear from the very beginning of this article, there is no standard model for wiring low voltage switchboards and panelboards. However, for the wide variety of installations and ranges of power ratings, there are local work practices, regulations… Read more
Apr 26, 2021 | By Edvard Csanyi