Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Author: Edvard Csanyi (Technical Articles)

Edvard Csanyi

1769 awesome technical articles

Edvard Csanyi - Author at EEP-Electrical Engineering Portal

Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.

I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.

Biography: https://electrical-engineering-portal.com/edvard-csanyi

Electric Motor

The Design Basics Of Motor Protection Circuit Breaker

Application-specific variations of the MCCB, these breakers combine the short-circuit and isolation functionality of the MCCB with the motor overcurrent protection of a traditional overload relay. MPCBs are UL 489 Listed as circuit breakers and verified as motor overload relays. These… Read more

Dec 07, 2015 | By

Learn Design Of Motor Protection Circuit Breaker
Energy and Power

Learn How To Specify Current Transformers

Current transformers are used to supply information to the protective relays and/or current, power and energy metering “instruments”. For this purpose they must supply a secondary current proportional to the primary current flowing through them and must be adapted to… Read more

Dec 05, 2015 | By

Learn How To Specify Current Transformers
Protection

HV/MV/LV Transformer Protection Schemes

Transformer protection should take into account the power, voltage, vector group and the importance of the unit within a particular system. Depending on these factors, the transformers can be assigned to one of the two general groups. Let’s see these… Read more

Nov 28, 2015 | By

HV/MV/LV Transformer Protection Schemes
Electrical Lectures

The Mesh Current Method For Analysis Of Electric Circuits

The mesh current method of circuit analysis discussed in this technical article employs mesh currents as the independent variables. The idea is to write the appropriate number of independent equations, using mesh currents as the independent variables. Subsequent application of… Read more

Nov 25, 2015 | By

The Mesh Current Method For Analysis Of Electric Circuits
Energy and Power

Automatic Transfer System (ATS) Explained in Details

Using the basic building blocks of utility power, system topology, on-site generation, and uninterruptible power supplies, the basic role of the automatic transfer system may now be defined. In this role, the Automatic Transfer System must display the following characteristics:… Read more

Nov 20, 2015 | By

Operational Requirments of Automatic Transfer System


EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.