Author: Edvard Csanyi (Technical Articles)

Edvard Csanyi

1769 awesome technical articles

Edvard Csanyi - Author at EEP-Electrical Engineering Portal

Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.

I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.

Biography: https://electrical-engineering-portal.com/edvard-csanyi

Energy and Power

5 copper busbar jointing methods you should know

Efficient joints in copper busbar conductors can be made very simply by: Bolting Clamping Riveting Soldering Welding Bolting and clamping are used extensively on-site. Shaped busbars may be prefabricated by using friction stir welding. Bolted joints are formed by overlapping… Read more

Jun 17, 2015 | By

5 Copper Busbar Jointing Methods
Testing and Commissioning

Procedure for transformer lightning impulse test

The purpose of the impulse voltage test is to secure that the transformer insultations withstand the lightning overvoltages which may occur in service. Where: C1 – Impulse capacitor Rc – Charging resistor Rs – Series resistor Ra – Low-ohmic discharging resistor for… Read more

Jun 12, 2015 | By

Procedure for transformer lightning impulse test
Energy and Power

When To Use a Solidly Grounded System?

As is evident from the name, a solidly grounded system is one where the neutral of the system is directly connected to ground without introducing any intentional resistance in the ground circuit. With appropriate choice of the type and number… Read more

Jun 10, 2015 | By

Energy and Power

How to achieve selective coordination of circuit breakers

Selective coordination is often referred to simply as coordination. Coordination is defined in NEC® 240.2 as: “The proper localization of a fault condition to restrict outages to the equipment affected, accomplished by the choice of selective fault-protective devices.” It is… Read more

Jun 08, 2015 | By

Energy and Power

What Is The Poor Power Quality?

Most electrical and electronic equipment is designed to operate from a power supply with a particular specification that usually defines the minimum and maximum limits for RMS (root mean-square) voltage and frequency. There is an expectation on the part of… Read more

Jun 05, 2015 | By

What Is Poor Power Quality?
Energy and Power

Understanding Transfer Switch Transition Types

Transfer switches are used for quickly and safely transitioning all electrical power consumed by the circuit, equipment, or systems connected to the transfer switch output between those normal and emergency power sources. All electrical power consumed by the circuit, equipment, or… Read more

Jun 03, 2015 | By

Socomec transfer switch installed in switchboard
Energy and Power

The Philosophy Of Breaker Failure Protection

The separation of equipment into zones will only work successfully if the outputs of the protections can be guaranteed to do their job. This makes logical sense. For the bus protection in Figure 1 for example, the breakers X and… Read more

May 29, 2015 | By

Cables

Few Aspects of Copper versus Aluminium

The constructions of aluminum wire and terminals have both been revised from past years. At one time the conductor was nearly pure aluminum, now they are all much stronger 8000 series alloys, with physical characteristics similar to copper. The wire… Read more

May 27, 2015 | By

Few Aspects of Copper versus Aluminium
Electric Motor

5 most common motor load types

Certain load types are characteristic in the industrial world. Knowing the load profile (speed range, torque and power) is essential when selecting a suitable motor and frequency converter for the application. Some common load types are shown. There may also… Read more

May 20, 2015 | By

5 most common motor load types