Edvard Csanyi
1754 awesome technical articles
Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.
I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.
Biography: https://electrical-engineering-portal.com/edvard-csanyi
In Front Of The Third Electrical Systems Revolution in United States
A dizzying array of new energy technologies are reaching or nearing the marketplace. Newer choices to generate electricity include fuel cells, wind turbines, solar cells and microturbines. Energy storage is approaching practicality, for example through reversible fuel cells and flywheels…. Read more
Dec 02, 2013 | By Edvard Csanyi
Important in role of capacitors in distribution systems
Should the voltage on a circuit fall below a specified level for some reason, a device called a capacitor can momentarily maintain the voltage at line value. Basically, a capacitor serves the same purpose as a storage tank in a… Read more
Nov 27, 2013 | By Edvard Csanyi
General principles of electricity supply systems
The generation of electricity in most modern power stations is at 25 kV, and this voltage is then transformed to 400 kV for transmission. Virtually all the generators of electricity throughout the world are three-phase synchronous generators. The generator consists… Read more
Nov 25, 2013 | By Edvard Csanyi
Heat as one of the most common cause of motor failure
Heat is the most common cause of motor failure before reaching rated service life. Every increase of 10 degrees Centigrade of a motor’s windings above its design operating temperature cuts the life of the motor’s windings insulation by 50 percent,… Read more
Nov 22, 2013 | By Edvard Csanyi
Identity Card of Every Asynchronous Motor
A motor is characterized by different electrical and constructional parameters which identify its correct application field. The whole of all these parameters constitutes the rating of the machine and is reported on a nameplate positioned on the motor itself. Hereunder… Read more
Nov 18, 2013 | By Edvard Csanyi
Guidelines For The Construction And Maintenance Of Transmission Lines
The purpose of this article is to give a general overview of the steps that are necessary in the planning and construction of a typical overhead transmission line, to give newcomers to the trade a general format to follow, and… Read more
Nov 13, 2013 | By Edvard Csanyi
The Need for Load Shedding In Generating, Transmission and Distribution Systems
The need for load shedding generally arises from unforeseen causes, lack of sufficient power supply from deficiencies in generating, transmission and distribution capabilities. These conditions may stem from unusually higher than foreseen demands that may be due to the following:… Read more
Nov 11, 2013 | By Edvard Csanyi
What’s the worst source of fluctuations on a power supply system?
Electric arc furnaces are considered as being one of the worst source of fluctuations on a power supply system. The load cycles of arc furnaces vary widely, depending on size and metallurgical requirements. The first part of the cycle consists… Read more
Nov 08, 2013 | By Edvard Csanyi
Few Words About Stepper Motor (Advantages, Disadvantages and Classification)
A stepper motor is an electromechanical device which converts electrical pulses into discrete mechanical movements. The shaft or spindle of a stepper motor rotates in discrete step increments when electrical command pulses are applied to it in the proper sequence…. Read more
Nov 06, 2013 | By Edvard Csanyi
Practical calculations of lightning strikes frequency
We distinguish between the following frequencies of lightning strikes which can be relevant for a building or structure: ND – Frequency of direct lightning strikes to the building or structure;· NM – Frequency of close lightning strikes with electromagnetic effects;… Read more
Nov 04, 2013 | By Edvard Csanyi
4 motor designs identified in NEMA MG1
Performance requirements for various types of induction motors for use on standard sinewave power supplies are identified in NEMA MG1. Some of these types of motors are suitable for use in variable speed applications, dependent on the type of application…. Read more
Nov 01, 2013 | By Edvard Csanyi
What’s That Hissing, Cracking, Buzzing Noise?
Corona can be visible in the form of light, typically a purple glow, as corona generally consists of micro arcs. Darkening the environment can help to visualize the corona. We once attached a camera (set to a long exposure time)… Read more
Oct 30, 2013 | By Edvard Csanyi
Field Inspection and Testing of Medium-Voltage Motor Control Centres (MCCs)
Check MCC equipment for: alignment, levelness, and tightness of all bolting. Check all equipment for: removal of blocking, supports, temporary ties, and temporary wire jumpers. Check that all protective barriers are properly installed. Check door alignment of individual starter units… Read more
Oct 28, 2013 | By Edvard Csanyi
What’s important for water power designer to make the right choice of a turbine
The water power designer has to make a choice on the type of turbine that can be adopted for a particular project. After the range of head to be handled by a turbine has been evaluated by stream flow analysis… Read more
Oct 25, 2013 | By Edvard Csanyi
Eight important checks to do before powering up the dry-type transformer
The transformer should be powered up only after checking the following items: name plate ratings, parallel operation, connections: cables, busbars, tap change connections, grounding connection, thermal protective device, impurities removal and insulation resistance test. Make sure the name plate ratings… Read more
Oct 23, 2013 | By Edvard Csanyi
