Edvard Csanyi
1758 awesome technical articles
Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.
I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.
Biography: https://electrical-engineering-portal.com/edvard-csanyi
Erection procedure for HV switchgear (Part 1)
Before commencing erection of HV switchgear check that all connections are tight on busbars and on main circuits as well as auxiliary circuits. Examine the insulation very carefully, because there have been reported cases of burned out connections due to… Read more
Apr 29, 2013 | By Edvard Csanyi
Why Lamp Flickers Sometimes
Voltage regulation has been one of the most important problems of the electric industry since its inception. The sizes of many parts of a power system are determined largely by this one consideration alone. Large proportion of the selling price of electrical power… Read more
Apr 27, 2013 | By Edvard Csanyi
Overvoltages Caused by Lightning
Overvoltages of atmospheric origin arise from uncontrollable sources and their severity for the load depends on many parameters that are determined according to where the lightning strikes and the structure of the electrical network. The impact of lightning on a… Read more
Apr 26, 2013 | By Edvard Csanyi
3 generations of SCADA system architectures you should know about
SCADA systems have evolved in parallel with the growth and sophistication of modern computing technology. The following sections will provide a description of the following three generations of SCADA systems: First Generation – Monolithic Second Generation – Distributed Third Generation – Networked… Read more
Apr 22, 2013 | By Edvard Csanyi
Conductor Types Used For Overhead Lines
The international standards covering most conductor types for overhead lines are IEC 61089 (which supersedes IEC 207, 208, 209 and 210) and EN 50182 and 50183 (see Table 1). For 36 kV transmission and above both aluminium conductor steel reinforced… Read more
Apr 20, 2013 | By Edvard Csanyi
Using AC switchgear in DC applications
Switchgear designed for alternating current can carry at least the same rated continuous operational DC current. With direct current the skin effect in the circuits disappears and none of the specific effects associated with alternating currents such as hysteresis or… Read more
Apr 19, 2013 | By Edvard Csanyi
Visual Tasks of Typical Living Room Lighting
Most living rooms require flexible lighting design solutions because they serve a broad variety of changing functions. The lighting in a typical living room should comfortably serve small group conversation, larger social gatherings that include casual eating and drinking, and… Read more
Apr 17, 2013 | By Edvard Csanyi
What happened to forgotten papers of Nikola Tesla?
After Nikola Tesla died, there was a scramble by the United States government to find all of his papers, notes and research before other foreign powers could find them. Tesla’s nephew, Sava Kosanovic, reported that before the OAP had arrived,… Read more
Apr 15, 2013 | By Edvard Csanyi
Why we find wind energy delivery factor important?
The key economic performance measure of a power plant is the electrical energy it delivers over the year. Not all power produced is delivered to the paying customers. A fraction of it is used internally to power the control equipment,… Read more
Apr 13, 2013 | By Edvard Csanyi
Grounding systems and their 3-letter classification
Low voltage systems supplying to consumer premises are predominantly solidly grounded. Protective ground connection to consumer premises (or extending the supply system ground to consumer premises) is however done in different ways. The common system categories are defined below using a 3-letter… Read more
Apr 12, 2013 | By Edvard Csanyi
An overview of GFCI – Ground-fault circuit interrupter
The NEC requires that Ground-Fault Circuit Interrupters (GFCIs) be installed in many different rooms and locations in both public and private buildings. They are now required in bathrooms, kitchens, appliance rooms or spaces, and garages. In addition, they are required… Read more
Apr 10, 2013 | By Edvard Csanyi
Responding to Cyber Intrusion in SCADA System
Continued from technical article: Detecting Cyber Intrusion in SCADA System The “three R’s” of the response to cyber intrusion are: Recording, Reporting, and Restoring. Theoretically, it would be desirable to record all data communications into and out of all substation… Read more
Apr 08, 2013 | By Edvard Csanyi
Detecting Cyber Intrusion in SCADA System
One of the axioms of cyber security is that although it is extremely important to try to prevent intrusions into one’s systems and databases, it is essential that intrusions be detected if they do occur. One of the axioms of… Read more
Apr 06, 2013 | By Edvard Csanyi
Benefits and Potential Drawbacks of VSDs
VSDs (Variable Speed Drives) offer several benefits, some of which are relatively easy to quantify, and others of which are less tangible, but there are some potential drawbacks, which must be avoided. With rotodynamic pump installations, savings of between 30%… Read more
Apr 03, 2013 | By Edvard Csanyi
Active fire protection measures in power substation
Active fire protection measures are automatic fire protection measures that warn occupants of the existence of fire, and extinguish or control the fire. These measures are designed to automatically extinguish or control a fire at its earliest stage, without risking… Read more
Apr 01, 2013 | By Edvard Csanyi
