Edvard Csanyi
1758 awesome technical articles
Hi, I'm an electrical engineer, programmer and founder of EEP - Electrical Engineering Portal. I worked twelve years at Schneider Electric in the position of technical support for low- and medium-voltage projects and the design of busbar trunking systems.
I'm highly specialized in the design of LV/MV switchgear and low-voltage, high-power busbar trunking (<6300A) in substations, commercial buildings and industry facilities. I'm also a professional in AutoCAD programming.
Biography: https://electrical-engineering-portal.com/edvard-csanyi
Discrimination between residual current circuit breakers (RCCBs)
The operating principle of the residual current release is basically the detection of an earth fault current, by means of a toroid transformer which embraces all the live conductors, included the neutral if distributed. In absence of an earth fault,… Read more
Jan 11, 2013 | By Edvard Csanyi
Testing and Commissioning of Substation DC System
Power substation DC system consists of battery charger and battery. This is to verify the condition of battery and battery charger and commissioning of them. Following instruments will be used for testing: Multimeter. (Learn how to use it) Battery loading… Read more
Jan 09, 2013 | By Edvard Csanyi
Environmental Stresses On External Insulation
The external insulation (transmission line or substation) is exposed to electrical, mechanical, and environmental stresses. The applied voltage of an operating power system produces electrical stresses. The weather and the surroundings (industry, rural dust, oceans, etc.) produce additional environmental stresses…. Read more
Jan 07, 2013 | By Edvard Csanyi
Transformer routine test – The measurement of winding resistance
Measurement is made to check transformer windings and terminal connections and also both to use as reference for future measurements and to calculate the load loss values at reference (e.g. 75ºC) temperature. Measuring the winding resistance is done by using… Read more
Jan 05, 2013 | By Edvard Csanyi
Geographical Variation in the Wind Resource
Ultimately the winds are driven almost entirely by the sun’s energy, causing differential surface heating. The heating is most intense on land masses closer to the equator, and obviously the greatest heating occurs in the daytime, which means that the region of greatest… Read more
Jan 04, 2013 | By Edvard Csanyi
Brightness, Lamp Life and Efficiency of LED Fixtures
A typical LED fixture comprises four major component parts: an LED emitter, the fixture’s heat sink, driver and dimming control, and augmenting optics. The emitter includes the die, a thermal heat sink, lens, and outer package (Figure 1). The die… Read more
Jan 03, 2013 | By Edvard Csanyi
The Future of MOS-Controlled Thyristor (MCT)
The MCT is type of power semiconductor device that combines the capabilities of thyristor voltage and current with MOS gated turn-on and turn-off. It is a high power, high frequency, low conduction drop and a rugged device, which is more… Read more
Jan 01, 2013 | By Edvard Csanyi
Thank you very much, wish you all the best in 2013!
Well engineers, here we are… at the very end of this year! 2012 was very active for us, that’s for sure. EEP’s team worked very hard during year and brought to you a plenty of interesting technical articles and new… Read more
Dec 31, 2012 | By Edvard Csanyi
PLC Application For Speed Control of AC Motors With Variable Speed (VS) Drive
A common PLC application is the speed control of AC motors with variable speed (VS) drives. The diagram in Figure 1 shows an operator station used to manually control a VS drive. The programmable controller implementation of this station will… Read more
Dec 29, 2012 | By Edvard Csanyi
Importance of Transformer Inrush Current
When a transformer is taken off-line, there will be a certain amount of residual flux that can remain in the core due to the properties of the magnetic core material. The residual flux can be as much as 50 to… Read more
Dec 28, 2012 | By Edvard Csanyi
7 Golden Safety Rules for Working In HV Laboratory
Employees performing operations and testing work in high voltage laboratory are exposed to a greater hazard than most other employees. Safety rules MUST NOT be seen as a means of limiting our freedom, but should rather be looked upon as valuable… Read more
Dec 26, 2012 | By Edvard Csanyi
SCADA As The Heart Of a Distribution Management System
At a high level, the elements of a distribution automation system can be divided into three main areas: SCADA application and server(s) DMS applications and server(s) Trouble management applications and server(s) As was stated in the title, the Supervisory Control… Read more
Dec 25, 2012 | By Edvard Csanyi
Inspection and Test Procedures for Metal-Enclosed Busways
Visual and Mechanical Inspection Electrical Tests Test Values Test Values – Visual and Mechanical Test Values – Electrical Tables: TABLE 100.12 – US Standard Fasteners Bolt-Torque Values for Electrical Connections TABLE 100.1 – Insulation Resistance Test Values Electrical Apparatus and… Read more
Dec 22, 2012 | By Edvard Csanyi
Diverting the River Flow With Dam
Introduction to Dams Dam Characteristics Embankment Dams Homogeneous dams Zoned embankment dams Embankments dams with membrane Concrete Dams Gravity dams Buttress dams Arch and Cupola dams Other Dam types Missouri River Dam in South Dakota (VIDEO) Dams and weirs are… Read more
Dec 21, 2012 | By Edvard Csanyi
Short-Circuit Switching Capacity Definition
The switching capacity is the r.m.s value of a current at a given power factor cosφ as well as a given rated voltage at which a switchgear or a fuse can still shut-off under specified conditions in an operationally safe… Read more
Dec 20, 2012 | By Edvard Csanyi
