How Do We Define Hazardous Areas?
The first requirement is to know what a hazardous area is. The principal factors relevant to the classifications of a hazardous area are the nature of the gases or dust present in the potentially explosive atmosphere and the likelihood of… Read more
Feb 09, 2013 | By Edvard Csanyi
How Motor Really Works?
The basic working of a motor is based on the fact that when ‘a current carrying conductor is placed in a magnetic field, it experiences a force’. If you take a simple DC motor, it has a current-carrying coil supported… Read more
Feb 08, 2013 | By Edvard Csanyi
Did Tesla Discover the Secrets of Antigravity?
Nikola Tesla has been credited for the creation of much of the technology that we take for granted today. Without the genius of Tesla we would not have: Radio, Television, AC electricity, Tesla coil, Flourescent lighting, Neon lighting, Radio control… Read more
Feb 06, 2013 | By Edvard Csanyi
How to Monitor Wind Speed?
When considering wind power, most people ask what the average annual wind speed is and how to get that number. The usual response is that you must monitor the wind speed at your site for at least 12 months, preferably… Read more
Feb 04, 2013 | By Edvard Csanyi
What is transformer rating based on?
In the U.S., transformers are rated based on the power output they are capable of delivering continuously at a specified rated voltage and frequency under “usual” operating conditions without exceeding prescribed internal temperature limitations. Insulation is known to deteriorate with… Read more
Jan 30, 2013 | By Edvard Csanyi
How to manipulate energized conductors with hot stick
Hot sticks are poles made of an insulating material. They have tools and/or fittings on the ends which allow workers to manipulate energized conductors and equipment from a safe distance. Hot sticks vary in length depending on the voltage level… Read more
Jan 28, 2013 | By Edvard Csanyi
Power measurement in a three-phase system
Electrical power is measured with a wattmeter. A wattmeter consists of a current coil connected in series with load, while the other potential coil is connected parallel with load. Depending on the strength of each magnetic field movement, the pointer… Read more
Jan 19, 2013 | By Edvard Csanyi
Underground residential distribution layouts
Where general appearance, economics, congestion, or maintenance conditions make overhead construction inadvisable, underground construction is specified. While overhead lines have been ordinarily considered to be less expensive and easier to maintain, developments in underground cables and construction practices have narrowed… Read more
Jan 18, 2013 | By Edvard Csanyi
D.M.C.R. Protection Relay for Oil Transformer
Introduction to D.M.C.R. Faults detected on live transformer unit: Dielectric fluid level is detected as low Overheating is detected Excess pressure is detected Standards Possibilities of D.M.C.R.: Oil level control and gas detection Pressure control Temperature control The DMCR is… Read more
Jan 16, 2013 | By Edvard Csanyi
Purpose of Disconnect Switches In HV Substation
Switches may be of several types, the common characteristic is that none are designed to interrupt fault currents and the insulation or insulators associated with them must coordinate with the rest of the system and a BIL (Basic insulation level)… Read more
Jan 14, 2013 | By Edvard Csanyi
Testing and Commissioning of MV/HV Cables
Compare cable data with drawings and specifications. Inspect exposed sections of cables for physical damage. Inspect bolted electrical connections for high resistance using one or more of the following methods: Use of a low-resistance ohmmeter in accordance with Section 1.2 above…. Read more
Jan 12, 2013 | By Edvard Csanyi
Discrimination between residual current circuit breakers (RCCBs)
The operating principle of the residual current release is basically the detection of an earth fault current, by means of a toroid transformer which embraces all the live conductors, included the neutral if distributed. In absence of an earth fault,… Read more
Jan 11, 2013 | By Edvard Csanyi
Testing and Commissioning of Substation DC System
Power substation DC system consists of battery charger and battery. This is to verify the condition of battery and battery charger and commissioning of them. Following instruments will be used for testing: Multimeter. (Learn how to use it) Battery loading… Read more
Jan 09, 2013 | By Edvard Csanyi
Environmental Stresses On External Insulation
The external insulation (transmission line or substation) is exposed to electrical, mechanical, and environmental stresses. The applied voltage of an operating power system produces electrical stresses. The weather and the surroundings (industry, rural dust, oceans, etc.) produce additional environmental stresses…. Read more
Jan 07, 2013 | By Edvard Csanyi
Transformer routine test – The measurement of winding resistance
Measurement is made to check transformer windings and terminal connections and also both to use as reference for future measurements and to calculate the load loss values at reference (e.g. 75ºC) temperature. Measuring the winding resistance is done by using… Read more
Jan 05, 2013 | By Edvard Csanyi