Category 'Medium Voltage' - Technical Articles

The “Medium voltage” category is dedicated to technical articles about medium voltage, up to 35,000 V. This includes topics such as MV switchgear and its equipment (circuit breakers, disconnectors, earth disconnectors, protection relays, CTs, VTs, contactors, LV compartment, etc.), as well as testing and commissioning of MV switchgear. Special attention is given to testing and maintenance and challenges that engineers often face during the commissioning process.

Energy and Power

MV Circuit Breaker Or Vacuum Contactor? (2)

Continued from first part: MV Circuit Breaker Or Vacuum Contactor? (Part 1) When applied properly, both medium-voltage circuit breakers and medium-voltage fused contactors should provide decades of reliable service. Applied incorrectly, either can lead to major headaches. Characteristic Circuit Breaker Contactor… Read more

Jan 31, 2014 | By

MV Circuit Breaker Or Vacuum Contactor? PART 2 (on photo: SIEMENS's Sion vacuum circuit-breaker is designed for use in all common types of medium-voltage switchgear)
Energy and Power

MV Circuit Breaker Or Vacuum Contactor? (1)

To compare the application of medium-voltage circuit breakers and of fused contactors, we must understand the basic characteristics of each switching technology. Comparison presented here shows the major characteristics of medium-voltage circuit breakers and medium-voltage fused contactors that influence the… Read more

Jan 29, 2014 | By

Application considerations - Circuit breaker Vs Vacuum contactor (1)
Energy and Power

MCset – Air Insulated Switchgear with SF6 CB

MCset is Schneider Electric‘s AIS – Air Insulated Switchgear (indoor metal-enclosed device) intended for the MV section of HV/MV substations and high power MV/MV substations up to 24kV. Main component of MCset is circuit breaker which is SF6 type. MCset – Air… Read more

May 31, 2013 | By

MCset Air Insulated Switchgear with SF6 CB (up to 24kV)
Medium Voltage

Things You Should Know About Medium Voltage GIS

Environmental Concerns Safety Concerns Special Handling Procedures Installation Concerns Operation and Maintenance Concerns End of Life / Recycling Concerns Conclusion Medium voltage (5-38 kV) gas insulated switchgear (GIS) differs greatly from the medium voltage AIS – Air insulated switchgear commonly… Read more

Feb 20, 2013 | By

Things You Should Know About Medium Voltage GIS
Energy and Power

Arrangements of LV Utility Distribution Networks (2)

Continued from the previous part: Arrangements of LV Utility Distribution Networks (1) In the past, an underground cable service or the wall-mounted insulated conductors from an overhead line service, invariably terminated inside the consumer’s premises, where the cable-end sealing box, the utility… Read more

Dec 01, 2012 | By

Arrangements of LV Utility Distribution Networks
Energy and Power

Arrangements of LV Utility Distribution Networks

In European countries the standard 3-phase 4-wire distribution voltage level is 230/400 V. Many countries are currently converting their LV systems to the latest IEC standard of 230/400 V nominal (IEC 60038). Medium to large-sized towns and cities have underground… Read more

Nov 30, 2012 | By

Arrangements of LV Utility Distribution Networks
High Voltage

Electrical Safety Standards for LV/MV/HV (Part-3)

Continued from part 2 – Electrical Safety Standards for LV/MV/HV (Part-2) Standard: Northern Ireland Electricity (NIE), 6/025 ENA Code: Indian Electricity Rules / Central Electricity Authority Right of Way Clearance (As per GETCO Standard) Minimum clearances between Electrical Lines crossing… Read more

Nov 14, 2012 | By

Electrical Safety Standards for LV/MV/HV part 3
High Voltage

Electrical Safety Standards for LV/MV/HV (Part-2)

Continued from part 1 – Electrical Safety Standards for LV/MV/HV (Part-1) Standard: Northern Ireland Electricity (NIE), 6/025 ENA Clearances of Electrical Line to Ground and Roads Clearances of Electrical Line to Other Objects Clearances of Electrical Line to Trees and… Read more

Nov 12, 2012 | By

Electrical Safety Standards for LV/MV/HV part 2
High Voltage

Electrical Safety Standards for LV/MV/HV (Part-1)

Standard: Western Power Company Water Safely Clearance on Electrical Fires Minimum Approach Distance for Authorized Person Minimum Approach Distance for Ordinary Person Minimum Approach Distance for Vehicle and Plant for Ordinary Person .  Standard: New Zealand Electrical Code Min. Safe… Read more

Nov 07, 2012 | By

Electrical Safety Standards for LV/MV/HV (Part-1)