Category 'Transmission and Distribution' - Technical Articles

The “Transmission and Distribution” category contains technical articles dedicated to electricity transmission and distribution in high—and medium-voltage fields. This includes T&D equipment such as transmission and distribution lines, power transformers, capacitor banks, etc. Special attention is paid to installing, testing, and commissioning MV and HV equipment and troubleshooting various problems that may arise in power grids.

High Voltage

The Purpose of High Voltage Circuit Switchers

Circuit switchers have been developed to overcome some of the limitations of fusing for substation power transformers. Circuit switchers have SF6 gas interrupters and are designed to provide three-phase interruption (solving the unbalanced voltage considerations) and to provide protection for… Read more

Nov 16, 2012 | By

Vertical interrupter circuit switcher without integral disconnect switch
Transformers

Transformers Are Never Silent

Yes, we all know that transformers are never silent. This is actually quite impossible, but in an environmentally aware, highly regulated world, the issue is not the level of noise, but its nature – and it’s very important. Transformers emit… Read more

Oct 29, 2012 | By

A three-phase oil transformer 225 MVA, 275 kV
Protection

Overcurrent protection of transformer (NEC 450.3)

The overcurrent protection required for transformers is consider for Protection of Transformer only. Such overcurrent protection will not necessarily protect the primary or secondary conductors or equipment connected on the secondary side of the transformer. Introduction Overcurrent protection of transformers… Read more

Oct 08, 2012 | By

Overcurrent protection of transformer (NEC 450.3)
Power Substation

Designing of HV Power Substation and Layout

Introduction Earthing and Bonding Substation Earthing Calculation Methodology (Earthing Materials) Layout of Substation Different Layouts for Substations (single busbar, mesh, 1 1/2 cb) Principle of Substation Layouts (spatial separation, maintenance zones) Components of a Substation (cbs, cts, isolators, insulation, transformers etc.) Substations are the… Read more

Oct 01, 2012 | By

Designing of High Voltage Power Substation and Layout
High Voltage

Design of Overhead Transmission Line Foundation

The foundation is the name given to the system which transfers to the ground the various steady state (dead) and variable (live) loads developed by the transmission tower and conductors. Foundations may be variously subjected to compressive or bearing forces,… Read more

Sep 19, 2012 | By

Design of Overhead Transmission Line Foundation
Energy and Power

An Overview Of Smart Power Grid

The present electric grids use the technology of 1970’s. But with the advancement in various concepts of power generation, problems associated with power outages and thefts, and also due to increase in demand, we require a modernized grid to avail… Read more

Aug 20, 2012 | By

An Overview Of Smart Power Grid
Protection

Delayed Auto-Reclosing On EHV Systems

On highly interconnected transmission systems, where the loss of a single line is unlikely to cause two sections of the system to drift apart significantly and lose synchronism, delayed auto-reclosing can be employed. Dead times of the order of 5s-60s are commonly used…. Read more

Aug 11, 2012 | By

Delayed auto-reclose scheme logic
High Voltage

Primary Distribution Voltage Levels

Most distribution voltages are between 4 and 35 kV. In this article, unless otherwise specified, voltages are given as line-to-line voltages; this follows normal industry practice, but it is sometimes a source of confusion. The four major voltage classes are… Read more

Aug 10, 2012 | By

Primary Distribution Voltage Levels
High Voltage

The Structure Of Power System

An interconnected power system is a complex enterprise that may be subdivided into the following major subsystems: Generation Subsystem Transmission and Subtransmission Subsystem Distribution Subsystem Utilization Subsystem Generation subsystem includes generators and transformers. An essential component of power systems is… Read more

Aug 09, 2012 | By

The structure of power system
Energy and Power

Reliability of Compressed Air Energy Storage Plant

As the name implies, the compressed air energy storage (CAES) plant uses electricity to compress air which is stored in underground reservoirs. When electricity is needed, this compressed air is withdrawn, heated with gas or oil, and run through an expansion turbine… Read more

Aug 04, 2012 | By

Compressed air energy storage (CAES) plant
Cables

Types of Cable Installations in Electrical Network

There are a variety of ways to install power distribution cables. Each method ensures distribution of power with a unique degree of reliability, safety, economy, and quality for any specific set of conditions. These conditions include the electrical characteristics of… Read more

Jul 27, 2012 | By

Types of cable installations in electrical network


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.