Earth fault protection of an AC motor in four different earthing systems
One of the most common faults to occur on a motor is a stator winding fault. Whatever the initial form of the fault (phase phase, etc.) or the cause (cyclic overheating, etc.), the presence of the surrounding metallic frame and… Read more
Sep 10, 2018 | By Edvard Csanyi
The study of harmonics and LV energy compensation
The harmonic currents are mainly down to the nonlinear loads in the installations. The most frequent harmonic sources are linked to the use of electric arcs (welding, arc furnaces, discharge lamps, etc.) and to magnetic machines. Power electronics (converters, variable… Read more
Aug 20, 2018 | By Edvard Csanyi
The technology behind distributed control system (DCS) in a thermal power plant
A DCS is the heart of a thermal power plant’s instrumentation and control systems. DCS stands for ‘distributed control system’, and the term ‘distributed’ means that several processors are operating together. This is usually achieved by dedicating tasks to different…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Aug 09, 2018 | By Edvard Csanyi
8 practical applications of testing ground system using clamp-on tester
First of all, it is extremely important that the operator/engineer understand the ground system that is being tested. The clamp-on measurement works well in many situations, but it has limitations and is not applicable in some configurations. Clamp-on ground testing… Read more
Aug 08, 2018 | By Edvard Csanyi
Generator earthing and stator earth fault protection
Generating unit is a pretty complex system made up of the generator stator winding, its transformer and unit transformer (if present), the rotor with its field winding and excitation system, and the prime mover with its associated auxiliaries. Many different… Read more
Aug 06, 2018 | By Edvard Csanyi
An algorithmic approach to space optimized design of modular switchboards
Modular Switchboards are used for electrical power distribution in industrial and commercial locations. It is often important to know the dimensions of the Switchboards beforehand, especially in case of large installations like a Power Plant. The details are used for… Read more
Aug 01, 2018 | By Apurva Singh
Installing and setting into operation of automatically controlled compensation banks
During previous decades manufacturers of automatic compensation banks faced increasing competition worldwide. They were forced to produce as economically as possible. Now, new technologies have been developed compared with the past when capacitors were bigger and heavier. Minimizing capacitors enabled… Read more
Jul 23, 2018 | By Edvard Csanyi
How to create a specific neutral earthing system within existing one (islanding)
Each neutral earthing system has advantages and disadvantages for the safety of property, electromagnetic compatibility or continuity of service. The main system must therefore be chosen according to these criteria, but the characteristics of the system, the receivers, and the… Read more
Jul 18, 2018 | By Edvard Csanyi
Eight substation equipment needed to power up data center
A few years ago I participated in an interesting project Telenor Data Center in Belgrade – The most advanced technical building in the region of Central and Eastern Europe. The building extends to 2,600 square meters and has the most… Read more
Jul 11, 2018 | By Edvard Csanyi
Current heat losses produced by electrical operational equipment in LV switchgear
It is widely accepted by all manufacturers that accumulation of heat (leading to overheating of devices) in switchgear is one of the greatest risks that could shorten the life expectancy of a switchgear, thus potentially damaging electrical and electronic devices… Read more
May 28, 2018 | By Edvard Csanyi
How optical communication cables work and how they differ from other cables
In several previous articles I mentioned optical fibre in the context of substation automation, protection signaling, communication between electrical devices, LAN communications, etc. Now I will get into details of fibre optic basics, design, jointing/termination and installation. Let’s start the… Read more
May 23, 2018 | By Edvard Csanyi
Lecture Notes In DC Electric Sources and Principles Of Electrical Circuits
DC sources refer to sources of electrical energy which are associated with constant voltages and currents. A DC power supply can be constructed as an electronic circuit operating from the ac mains electricity supply and designed for purpose. Alternatively it… Read more
May 16, 2018 | By Edvard Csanyi
What is the Ground Potential Rise in your home and why you should take it seriously
People familiar with electricity frequently accept the idea that “Ground is ground,” i.e., that in a house, especially with a grounding system that complies with the NEC or CEC, all points of the grounding system are at the same voltage…. Read more
Apr 30, 2018 | By Edvard Csanyi
Have you ever encountered an incorrectly specified CT that cannot be manufactured?
When a CT manufacturer says that he is unable to manufacture the requested CT, nine times out of ten this is because the CT has been incorrectly specified. To eliminate all the cumulated safety margins taken by all the people involved,… Read more
Mar 07, 2018 | By Edvard Csanyi
Step-by-step tutorial for building capacitor bank and reactive power compensation panel
Design of reactive power compensation panel is much different and not that simple like standard distribution panel. When dealing with such panels, there are dozen of parameters to specify and other things to take care of. This article is the… Read more
Feb 28, 2018 | By Edvard Csanyi