Improvement of Power Quality via Dynamic Reactive Power Compensation Systems
In many cases, industrial plants are characterized in particular by the use of highly dynamic drive technology. In addition to the undeniable advantages of these modern technologies, there is the disadvantage that the electrical networks are strained because of frequent… Read more
Oct 11, 2017 | By Edvard Csanyi
The Structure of Electric Power Systems: Energy Generation, Distribution and Transmission
From a general perspective, an electric power system is usually understood as a very large network that links power plants (large or small) to loads, by means of an electric grid that may span a whole continent, such as Europe… Read more
Oct 09, 2017 | By Edvard Csanyi
How to choose a form of separation for LV switchboard and how to classify them
By form of separation it is meant the type of subdivision provided within the switchboard. Separation by means of barriers or partitions (metallic or insulating) may have several functions. And these functions: Provide protection against direct contact (at least IPXXB)… Read more
Sep 25, 2017 | By Edvard Csanyi
Rules for power distribution in LV switchgear and protection of branch / distributed lines
In designing a power distribution concept, encompassing the sizing of systems and devices, it is essential to align the requirements and feasibility with both the end user and the manufacturer. The appropriate sizing of low-voltage switchgear necessitates an understanding of… Read more
Sep 20, 2017 | By Edvard Csanyi
Installing a submarine transmission cable, how they do it
Installing a submarine transmission cable is a costly and challenging activity. The lifetime of a submarine cable might be tens of years and the technical interventions for its repairing in case of faults are also costly and difficult. Therefore the… Read more
Sep 11, 2017 | By Edvard Csanyi
Specific capacitor installations & reactive compensation of asynchronous motors / transformers
Although in general, the calculation of the reactive power to be installed is initially carried out globally, it is advisable not to be swayed by the apparent simplicity of this process, and to look further for the optimum locations for… Read more
Aug 30, 2017 | By Edvard Csanyi
Should transfer switch be equipped with contactors or circuit breakers? Manual or automatic?
Transfer switches support multiple operation modes (manual, automatic, non-automatic, bypass isolation, etc.) and feature a range of different switching mechanisms (contactors, circuit breakers). Transfer switches are used to protect critical electrical loads against loss of power. The load’s normal power… Read more
Aug 23, 2017 | By Edvard Csanyi
Nine power generating units grouped by prime mover you should know about
Many types of power generating plants are in use and possible for the future, including steam plants fueled by coal, oil, or gas, nuclear plants, hydro plants and plants which use renewable energy. Most types of power generating units can… Read more
Aug 18, 2017 | By Edvard Csanyi
5 special applications of residual current devices (RCDs)
Normally residual current devices (RCDs) are used for protection against direct and indirect contacts. An RCD can detect low leakage currents that could flow through the body of a person. It thus provides additional protection if the normal protection means… Read more
Aug 16, 2017 | By Edvard Csanyi
The essentials of MV/HV magnetic voltage transformers
Magnetic voltage transformers are used to provide a secondary signal that is proportional to the actual prevailing primary value. These signals are used to supply measuring instruments, meters, relays and other similar apparatuses. The primary values measured are system currents… Read more
Aug 14, 2017 | By Edvard Csanyi
Ten equipment you MUST recognize in every distribution substation
Distribution substation is a substation from which electric supply is distributed to the different users. In a substation there are numbers of incoming and outgoing circuits each having its isolator, circuit breaker, transformers etc. connected to bus-bar system. These equipment… Read more
Aug 11, 2017 | By Edvard Csanyi
The most common methods of measuring the resistance of an earth electrode
When an earth electrode system has been designed and installed, it is usually necessary to measure and confirm the earth resistance between the electrode and “true Earth”. The most commonly used method of measuring the earth resistance of an earth… Read more
Aug 09, 2017 | By Edvard Csanyi
Practical advice for positioning of circuit breakers inside LV switchboard
Mounting of the different mechanical and electrical components (enclosures, busbars, functional units – circuit breakers, etc.) which constitute the LV switchboard defined by the original manufacturer must be carried out in compliance with the instructions (technical catalogue/assembly instruction manual) of… Read more
Aug 07, 2017 | By Edvard Csanyi
MV network diagrams for feeding secondary switchboards and MV/LV transformers
Let’s take a look at the main MV network diagrams and structures used to feed secondary switchboards and MV/LV transformers. The complexity of the diagrams differs, depending on the level of power supply security required. Note that there are many… Read more
Aug 04, 2017 | By Edvard Csanyi
How to install a manual transfer switch for a backup system in 16 steps
A manual transfer switch is installed next to the main service panel to override the normal electrical service with power from a backup generator during a power outage. Manual transfer switches require an operator to change the power source, while… Read more
Aug 02, 2017 | By Edvard Csanyi