Six network operating conditions under which ferroresonance can occur
Due to the multitude of various sources of capacitances and non-linear inductances in a real power network and the wide range of operating conditions, configurations under which ferroresonance can occur are endless. Experience has, however, made it possible to list… Read more
Apr 12, 2017 | By Edvard Csanyi
8 essential relay operating principles of catching faults
In general, as faults (short circuits) occur, currents increase in magnitude, and voltages go down. Besides these magnitude changes of the AC quantities, other changes may occur in one or more of the following parameters: phase angles of current and… Read more
Apr 10, 2017 | By Edvard Csanyi
Three main techniques for mitigating step and touch potential hazards
Mitigating step and touch potential hazards is usually accomplished through one or more of the following three main techniques. Understanding the proper application of discussed techniques is the key to reducing and eliminating any ground potential rise hazards. Contents: Reduction… Read more
Apr 07, 2017 | By Edvard Csanyi
How good are you at reading electrical drawings? Take the quiz.
Every electrician, in every branch of electrical work, will need to consult and understand the information presented on electrical drawings to locate the various outlets, the routing of circuits, the location and size of panelboards, and other similar electrical details…. Read more
Apr 05, 2017 | By Edvard Csanyi
Two main functions of an earth electrode and its installation parameters
The prime function of an earth electrode is the protection of persons. That’s it. It is a fact that we live on Earth! And it is vital to earth exposed metal parts of electrical equipment to avoid electrocution by indirect… Read more
Apr 03, 2017 | By Edvard Csanyi
Wiring of power factor relay on LV and MV side (circuit diagrams)
In order to measure electrical power the relay needs to receive the line voltage and current from a current transformer (CT) installed close to the metering point, if possible. To measure reactive power at the power factor relay especially, it… Read more
Mar 31, 2017 | By Edvard Csanyi
Five protection relay types used to detect grid disturbances and isolating
Consider a medium voltage distribution system having local generation (e.g., captive power generation) as shown in figure 1 which is also synchronized with the grid. During grid disturbance, if plant generators are not successfully isolated from the grid, they also sink… Read more
Mar 29, 2017 | By Edvard Csanyi
Top six solutions to achieve a high level of energy efficiency in buildings
Energy efficiency in commercial buildings involves providing a given level of performance, cost, quality, availability, and comfort at a minimal level of energy usage throughout the lifecycle of a given asset or process. Generally speaking, energy efficiency involves reducing energy… Read more
Mar 27, 2017 | By Edvard Csanyi
Installation, protection and connection of capacitor banks
In an low voltage electrical installation, capacitor banks can be installed at three different levels: Global installation Segment (or group) installation Individual (or single) installation After installation ways, we’ll discuss about protection and connection of capacitors banks. This installation type assumes… Read more
Mar 20, 2017 | By Edvard Csanyi
What is the complex power and how it figures in power analysis
Considerable effort has been expended over the years to express power relations as simply as possible. Power engineers have coined the term complex power, which they use to find the total effect of parallel loads. Complex power is important in… Read more
Mar 17, 2017 | By Edvard Csanyi
Three performance factors you must consider when sizing batteries
Batteries need to be sized correctly to be able to feed the required load for the required time, and a number of factors need to be decided to be able to optimize the battery for the duty expected. Some of… Read more
Mar 10, 2017 | By Edvard Csanyi
The essentials of synchronous machines in power distribution networks
Synchronous machines can be used as generators or motors. They are of 3-phase construction, even though some special exceptions can be found. A bulk of the applications are within power ranges roughly varying from a megawatt level to several tenths… Read more
Mar 06, 2017 | By Edvard Csanyi
Voltage drop calculation methods with examples explained in details
What we call “voltage drop” is really just the differential in voltage between where the installation started and where the receptor was connected. The primary concern with voltage drop is that, under steady-state conditions of typical load, the voltage at the… Read more
Mar 03, 2017 | By Edvard Csanyi
Do you know what ground potential rise is? It’s really important.
First of all, ground potential rise is very important and very dangerous event. The grounding engineer will be required to develop safety systems to protect any personnel working where ground potential rise hazards are known to exist. Federal law mandates… Read more
Feb 22, 2017 | By Edvard Csanyi
5 good examples of locking out HV/MV/LV structures and equipment
In all cases the choice of locks and safety positions requires prior analysis of the locking sequence to be applied in order to correctly define the requirement and clearly identify the related risks. Remember that “electric” locking systems are never… Read more
Feb 17, 2017 | By Edvard Csanyi