Category 'Energy and Power' - Technical Articles

“Energy and Power” category deals with technical articles dedicated to electrical engineering in general. You will find here many useful information on generation, transmission and distribution of electricity, substation operation rules, low & medium voltage equipment, and rules that electrical engineers must follow during the start-up and commissioning, etc.

Energy and Power

What makes a good grounding system?

The performance of the grounding system is determined by the quality of the following five components all of which are of equal importance. The grounding electrode conductor The grounding connections The grounding electrode Electrode to soil resistance The soil Typically… Read more

Mar 09, 2016 | By

What makes a good grounding system?
Energy and Power

Things you MUST verify when designing low voltage switchgear

Low voltage switchgear and distribution boards form the link between the equipment for the generation (generators), transmission (cables, overhead lines) and transformation (transformers) of electrical energy on the one hand and the consumers, e.g. motors, solenoid valves, devices for heating,… Read more

Mar 02, 2016 | By

6 things you MUST know when designing low voltage switchgear
Energy and Power

The Basics Of Molded Case Circuit Breakers You MUST Know

Molded case circuit breakers are interrupting devices with self-contained, current-responsive elements. These breakers are assembled as an integral unit in a supported and enclosed housing of insulating material. Depending on the amount of protection required, these breakers can sense internally… Read more

Feb 27, 2016 | By

The Basics Of Molded Case Circuit Breakers You MUST Know
Energy and Power

DC Testing Methods Conducted On Solid Insulation

Let’s take a look at the two important tests that are conducted with DC voltage. Two tests can be conducted on solid insulation using following DC testing methods: insulation resistance testing and high-potential (Hi-pot) voltage testing. Table of contents: Insulation… Read more

Feb 10, 2016 | By

DC Testing Methods Conducted On Solid Insulation
Energy and Power

How electricians test continuity of protective conductors

For all protective conductors, including main and supplementary bonding conductors, electricians must perform continuity test using a low-reading ohmmeter. For main equipotential bonding, there is no single fixed value of resistance above which the conductor would be deemed unsuitable. Each… Read more

Feb 06, 2016 | By

Continuity of protective conductors
Energy and Power

Where do electrical faults occur the most?

A fault is not a natural occurrence. It is an unplanned event which occurs unexpectedly. Electrical faults in an electrical installation or piece of equipment may be caused by: Negligence (that is, lack of proper care and attention), Misuse (that is,… Read more

Feb 01, 2016 | By

Where Do Electrical Faults Occur The Most?
Energy and Power

Why I prefer busbar trunking systems more than cables

When a planning concept for power supply is developed, it is not only imperative to observe standards and regulations, it is also important to discuss and clarify economic and technical interrelations (cables and/or busbar trunking systems depending on situations). The… Read more

Jan 30, 2016 | By

Why I Prefer Busbar Trunking Systems More Than Cables