Learn To Interpret Single Line Diagram (SLD)
We usually depict the electrical distribution system by a graphic representation called a single line diagram (SLD). A single line can show all or part of a system. It is very versatile and comprehensive because it can depict very simple… Read more
Dec 19, 2015 | By Edvard Csanyi
The good ventilation of switchgear and transformer rooms
In order to design a good ventilation of switchgear and transformer rooms, the air in the room must meet various requirements. The most important is not to exceed the permissible maximum temperature. Limit values for humidity and air quality, e.g…. Read more
Dec 18, 2015 | By Edvard Csanyi
Distribution of the MV neutral conductor right to the loads
4-wire systems are characterized by distribution of the MV neutral conductor right to the loads. This type of distribution is used in the USA and in certain countries influenced by North America, and is always subject to ANSI regulations. It… Read more
Dec 16, 2015 | By Edvard Csanyi
The basics of primary medium voltage switchgear
Primary medium voltage switchgear represents an important part within the primary distribution substation functionality. The switchgear works as a connection node between the outgoing distribution feeders and the in-feeding power transformers. The most common construction with the switchgear is an… Read more
Dec 14, 2015 | By Edvard Csanyi
Real time reactive compensation – A case with 5 problems and solutions
A car equipment manufacturer’s plant in Concord (Ontario, Canada) is supplied by a transformer rated at 2000 kVA – 27.6 kV / 600 V – Yy – Ucc = 5.23 %. It manufactures exhaust assemblies from steel plate using spot welders and… Read more
Dec 11, 2015 | By Edvard Csanyi
The Design Basics Of Motor Protection Circuit Breaker
Application-specific variations of the MCCB, these breakers combine the short-circuit and isolation functionality of the MCCB with the motor overcurrent protection of a traditional overload relay. MPCBs are UL 489 Listed as circuit breakers and verified as motor overload relays. These… Read more
Dec 07, 2015 | By Edvard Csanyi
Learn How To Specify Current Transformers
Current transformers are used to supply information to the protective relays and/or current, power and energy metering “instruments”. For this purpose they must supply a secondary current proportional to the primary current flowing through them and must be adapted to… Read more
Dec 05, 2015 | By Edvard Csanyi
7 guidelines to select correctly rated circuit breaker
The general procedure for the selection of correctly rated circuit breaker follows the following scheme of seven major questions you should answer. Let’s see the major questions: What is the task of the branch circuit or feeder? Which rated current… Read more
Dec 04, 2015 | By Edvard Csanyi
The Mesh Current Method For Analysis Of Electric Circuits
The mesh current method of circuit analysis discussed in this technical article employs mesh currents as the independent variables. The idea is to write the appropriate number of independent equations, using mesh currents as the independent variables. Subsequent application of… Read more
Nov 25, 2015 | By Edvard Csanyi
Automatic transfer system explained in detail (operational requirements)
In a previous article I explained the role of the automatic transfer system and the operational requirements – three modes of operation: manual mode, automatic mode, and auto mode failure. Now let’s cover the following topics and try to explain the concept… Read more
Nov 21, 2015 | By Edvard Csanyi
Automatic Transfer System (ATS) Explained in Details
Using the basic building blocks of utility power, system topology, on-site generation, and uninterruptible power supplies, the basic role of the automatic transfer system may now be defined. In this role, the Automatic Transfer System must display the following characteristics:… Read more
Nov 20, 2015 | By Edvard Csanyi
Example On How To Design a Low Voltage Switchboard
This technical article has the aim of helping the panel builder and the designer in the construction of ABB SACE ArTu low voltage switchboard. To this purpose, starting from the single-line diagram of a plant, it is possible to arrive… Read more
Nov 18, 2015 | By Edvard Csanyi
Primary distribution schemes of power plants on board of big ships
The MV primary distribution network generally consists in a three-phase system with three conductors without neutral. Such system is usually managed with the neutral of the star point isolated from earth or connected with earth through a resistance or a… Read more
Nov 16, 2015 | By Edvard Csanyi
The Tesla Electric Light Company in Electrical Review, August 14, 1886
Electrical Review, August 14, 1886 – A weekly journal of electric light, telephone telegraph and scientific progress This company has been organized nearly two years, and has devoted that tittle, to perfecting a complete arc-light system, which we take pleasure… Read more
Nov 14, 2015 | By Edvard Csanyi
Single-line diagram of the AC transmission and distribution system
The conductor system by means of which electric power is conveyed from a generating station to the consumer’s premises may, in general, be divided into two distinct parts i.e. transmission system and distribution system. Each part can again be sub-divided… Read more
Nov 13, 2015 | By Edvard Csanyi