Category 'Energy and Power' - Technical Articles

“Energy and Power” category deals with technical articles dedicated to electrical engineering in general. You will find here many useful information on generation, transmission and distribution of electricity, substation operation rules, low & medium voltage equipment, and rules that electrical engineers must follow during the start-up and commissioning, etc.

Energy and Power

Smart Grid Concept and Characteristics

A smart grid is an electricity network that uses digital and other advanced technologies to monitor and manage the transport of electricity from all generation sources to meet the varying electricity demands of end-users. Smart grids co-ordinate the needs and… Read more

Mar 21, 2012 | By

Smart Grid
Energy and Power

Few more words about energy stored in batteries

Electrochemical storage systems In this article various types of batteries are described. Most of them are technologically mature for practical use. First, six secondary battery types are listed: lead acid, NiCd/NiMH, Li-ion, metal air, sodium sulphur and sodium nickel chloride;… Read more

Mar 19, 2012 | By

High-efficiency lead acid batteries
Cables

Copper or aluminium? Which one to use and when?

Apart from their electrical conductivity, the other technologically important properties of copper and aluminium differ so significantly (density is an obvious example) that their areas of application are and have always been clearly distinct. And not a lot has changed… Read more

Mar 16, 2012 | By

System with two copper bus bars
Energy and Power

Megger Insulation Resistance Test

As you know good insulation has high resistance and poor insulation relatively low resistance. The actual resistance values can be higher or lower, depending upon such factors as the temperature or moisture content of the insulation (resistance decreases in temperature… Read more

Mar 13, 2012 | By

Megger Insulation Resistance Test
Energy and Power

The real truth behind household power savers

A household power low voltage saving devices has recently received a lot of attention from both consumers and manufacturers. It is generally used in residential homes to save energy and to reduce electricity bills. It is a small device which… Read more

Mar 07, 2012 | By

The real truth behind household power savers
Electrical Lectures

Capacitor Banks In Power System (part three)

Continued from part two – Capacitor Banks In Power System (part two) Capacitor units shall be suitable for continuous operation at an RMS current of 1.30 times the current that occurs at rated sinusoidal voltage and rated frequency, excluding transients…. Read more

Mar 03, 2012 | By

Low Voltage Power Capacitor
Electrical Lectures

Capacitor Banks In Power System (part two)

Continued from part one – Capacitor Banks In Power System (part one) It should be noted that in an inductance the current lags the voltage by 90 degrees and in a capacitor the current leads the voltage by 90 degrees…. Read more

Mar 01, 2012 | By

Capacitor banks in low voltage switchgear
Electrical Lectures

Capacitor banks in power system (part 1)

When a charge is delivered to a conductor its potential is raised in proportion to the quantity of charge given to it. At a particular potential a conductor can hold a given amount of charge. Capacitance is the term to… Read more

Feb 27, 2012 | By

Capacitor banks in power system (part 1)
Energy and Power

220V DC system at thermal power station

The 220V DC system supplies direct current as source of operating power for control, signaling, relays, tripping and closing of switchgears, emergency motors of most important auxiliary systems. Under normal conditions of station generation, the storage battery units are kept… Read more

Feb 15, 2012 | By

220V DC system at thermal power station
Electrical Lectures

Types of neutral earthing in power distribution (part 2)

Resistance grounding has been used in three-phase industrial applications for many years and it resolves many of the problems associated with solidly grounded and ungrounded systems. Resistance Grounding Systems limits the phase-to-ground fault currents. Continued from Types of neutral earthing… Read more

Feb 09, 2012 | By

Low voltage switchgear - Power distribution
Cables

Discussing About LV And HV Electrical Cables

Space is really a critical criterion when discussing electrical cables and wires. In a low-voltage (LV) plastic-sheathed cable with conductor cross-sections of up to 10 mm2 per conductor or in high-voltage (HV) cables (Figure 2), the lion’s share of the… Read more

Feb 08, 2012 | By

High-voltage cable cross section