Search

Premium Membership ♕

Join EEP PREMIUM today to unlock professional articles, specialized guides, and 50% discount on academy courses (lifetime access included)

Category 'High Voltage' - Technical Articles

“High Voltage” category refers to technical articles related to applications of rated voltage over 35,000 V (35 kV) and up to 800 kV. This also includes an Ultra High Voltage (UHV) transmission networks. This category includes topics related to electrical transmission theory, HV switchyard specifications and design advice, maintenance tips, testing and commissioning rules, etc.

High Voltage

SF6 gas as insulating and arc-quenching medium

Sulphur hexafluoride gas (SF6) is employed as insulation in all parts of the installation, and in the circuit-breaker also for arc-quenching. SF6 is an electronegative gas, its dielectric strength at atmospheric pressure is approximately three times that of air. It… Read more

Jan 06, 2011 | By

High Voltage

Use Of Vacuum As A Breaking Medium

SF6 and vacuum are the two most modern breaking techniques in the fields of Medium Voltage (from 1 to 52 kV) and High Voltage (> 72.5 kV). They appeared in the 1960’s and rapidly developed as of the 1970’s. Today… Read more

Dec 22, 2010 | By

Fig-1 Evolution Of MV Circuit Breaker Markets In Europe
High Voltage

Basics Of Subtransmission Systems

Subtransmission systems are those circuits that supply distribution substations. Several different subtransmission systems can supply distribution substations. Common subtransmission voltages include 34.5, 69, 115, and 138 kV. Higher voltage subtransmission lines can carry more power with less losses over greater… Read more

Dec 17, 2010 | By

Transmission Lines
High Voltage

IEC 62271-200 – HV Switchgear And Controlgear

Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV Switchgears are important nodal points in modern power distribution. Correspondingly important is their reliable functioning, a clearly defined switching behavior… Read more

Dec 09, 2010 | By

IEC 62271-200
High Voltage

Gas-Insulated Substations – GIS

A gas-insulated substation (GIS) uses a superior dielectric gas, SF6, at moderate pressure for phase-tophase and phase-to-ground insulation. The high voltage conductors, circuit breaker interrupters, switches, current transformers, and voltage transformers are in SF6 gas inside grounded metal enclosures. The… Read more

Nov 10, 2010 | By

Gas-Insulated Substations - GIS


Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

EEP Hand-Crafted Video Courses

Check more than a hundred hand-crafted video courses and learn from experienced engineers. Lifetime access included.
Experience matters. Premium membership gives you an opportunity to study specialized technical articles, online video courses, electrical engineering guides, and papers written by experienced electrical engineers.
Whitepaper: How to Improve Risk Decisions for Power Systems - Prioritizing vulnerabilities with full operational context