Category 'IEC Standards' - Technical Articles

The International Electrotechnical Commission (IEC) is a non-profit, non-governmental international standards organization that prepares and publishes International Standards for all electrical, electronic and related technologies – collectively known as “electrotechnology”.

Energy and Power

Conceptual Model of Smart Grid Framework by IEC

From a communication point of view, each system plays the role of either supplier or consumer of information, or more typically both. In addition to this intersystem communication, these systems consist of subsystems with specific internal communications. The following paragraphs… Read more

Feb 03, 2014 | By

Conceptual model of smart grid framework
Energy and Power

UK Electrical Industry British Standards (BS)

These standards are the whole of the prescriptions on the basis of which machines, apparatus, materials and the installations should be designed, manufactured and tested so that efficiency and function safety are ensured – and all according to the UK Electrical… Read more

Jan 20, 2012 | By

British Standards (BSI)
Energy and Power

Protection Relay – ANSI Standards

In the design of electrical power systems, the ANSI Standard Device Numbers denote what features a protective device supports (such as a relay or circuit breaker). These types of devices protect electrical systems and components from damage when an unwanted… Read more

Feb 22, 2011 | By

Protection Relay - ANSI Standards
IEC Standards

IP Protection Degree (IEC 60529) Explained

The protection of enclosures against ingress of dirt or against the ingress of water is defined in IEC529 (BSEN60529:1991). Conversely, an enclosure which protects equipment against ingress of particles will also protect a person from potential hazards within that enclosure,… Read more

Feb 19, 2011 | By

IP Protection Degree (IEC 60529) Explained
IEC Standards

Advantages Of IEC 61850

One of the significant challenges that substation engineers face is justifying substation automation investments. The positive impacts that automation has on operating costs, increased power quality, and reduced outage response are well known. But little attention is paid to how… Read more

Dec 29, 2010 | By

Advantages Of IEC 61850 Standard
High Voltage

IEC 62271-200 – HV Switchgear And Controlgear

Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV Switchgears are important nodal points in modern power distribution. Correspondingly important is their reliable functioning, a clearly defined switching behavior… Read more

Dec 09, 2010 | By

IEC 62271-200