Category 'Medium Voltage' - Technical Articles

The “Medium voltage” category is dedicated to technical articles about medium voltage, up to 35,000 V. This includes topics such as MV switchgear and its equipment (circuit breakers, disconnectors, earth disconnectors, protection relays, CTs, VTs, contactors, LV compartment, etc.), as well as testing and commissioning of MV switchgear. Special attention is given to testing and maintenance and challenges that engineers often face during the commissioning process.

Medium Voltage

Microprocessor and conventional secondary systems compared

Secondary systems are all those facilities needed to ensure reliable operation of the primary system, e.g. a high voltage substation. They cover the functions of controlling, interlocking, signalling and monitoring, measuring, counting, recording and protecting. With conventional secondary systems, the… Read more

Jul 09, 2014 | By

Microprocessor and conventional secondary systems compared
Medium Voltage

The role of medium voltage switchgear in power system

Most electrical appliances used in household, commercial and industrial applications work with low voltage. High voltage is used not only to transmit electrical energy over very large distances, but also for regional distribution to the load centers via fine branches…. Read more

May 23, 2014 | By

The role of medium voltage switchgear in power system
Energy and Power

MV Circuit Breaker Or Vacuum Contactor? (2)

Continued from first part: MV Circuit Breaker Or Vacuum Contactor? (Part 1) When applied properly, both medium-voltage circuit breakers and medium-voltage fused contactors should provide decades of reliable service. Applied incorrectly, either can lead to major headaches. Characteristic Circuit Breaker Contactor… Read more

Jan 31, 2014 | By

MV Circuit Breaker Or Vacuum Contactor? PART 2 (on photo: SIEMENS's Sion vacuum circuit-breaker is designed for use in all common types of medium-voltage switchgear)
Energy and Power

MV Circuit Breaker Or Vacuum Contactor? (1)

To compare the application of medium-voltage circuit breakers and of fused contactors, we must understand the basic characteristics of each switching technology. Comparison presented here shows the major characteristics of medium-voltage circuit breakers and medium-voltage fused contactors that influence the… Read more

Jan 29, 2014 | By

Application considerations - Circuit breaker Vs Vacuum contactor (1)
Energy and Power

MCset – Air Insulated Switchgear with SF6 CB

MCset is Schneider Electric‘s AIS – Air Insulated Switchgear (indoor metal-enclosed device) intended for the MV section of HV/MV substations and high power MV/MV substations up to 24kV. Main component of MCset is circuit breaker which is SF6 type. MCset – Air… Read more

May 31, 2013 | By

MCset Air Insulated Switchgear with SF6 CB (up to 24kV)
Medium Voltage

Things You Should Know About Medium Voltage GIS

Environmental Concerns Safety Concerns Special Handling Procedures Installation Concerns Operation and Maintenance Concerns End of Life / Recycling Concerns Conclusion Medium voltage (5-38 kV) gas insulated switchgear (GIS) differs greatly from the medium voltage AIS – Air insulated switchgear commonly… Read more

Feb 20, 2013 | By

Things You Should Know About Medium Voltage GIS
Energy and Power

Arrangements of LV Utility Distribution Networks (2)

Continued from the previous part: Arrangements of LV Utility Distribution Networks (1) In the past, an underground cable service or the wall-mounted insulated conductors from an overhead line service, invariably terminated inside the consumer’s premises, where the cable-end sealing box, the utility… Read more

Dec 01, 2012 | By

Arrangements of LV Utility Distribution Networks
Energy and Power

Arrangements of LV Utility Distribution Networks

In European countries the standard 3-phase 4-wire distribution voltage level is 230/400 V. Many countries are currently converting their LV systems to the latest IEC standard of 230/400 V nominal (IEC 60038). Medium to large-sized towns and cities have underground… Read more

Nov 30, 2012 | By

Arrangements of LV Utility Distribution Networks
High Voltage

Electrical Safety Standards for LV/MV/HV (Part-3)

Continued from part 2 – Electrical Safety Standards for LV/MV/HV (Part-2) Standard: Northern Ireland Electricity (NIE), 6/025 ENA Code: Indian Electricity Rules / Central Electricity Authority Right of Way Clearance (As per GETCO Standard) Minimum clearances between Electrical Lines crossing… Read more

Nov 14, 2012 | By

Electrical Safety Standards for LV/MV/HV part 3