Example of MV/LV network structure with dual fed main MV switchboard
Connected to article: Example of standard MV/LV network structure MV consumer substation; The main MV switchboard can be backed up by a generator set and it feeds two MV/LV transformers; MV switchboard can be GIS or AIS and consist of… Read more
Jan 06, 2014 | By Edvard Csanyi
Field Inspection and Testing of Medium-Voltage Motor Control Centres (MCCs)
Check MCC equipment for: alignment, levelness, and tightness of all bolting. Check all equipment for: removal of blocking, supports, temporary ties, and temporary wire jumpers. Check that all protective barriers are properly installed. Check door alignment of individual starter units… Read more
Oct 28, 2013 | By Edvard Csanyi
Five special transformers for industrial applications you should know about
A number of industry applications require specific industrial transformers due to the usage of power (current) as a major resource for production. Electric arc furnaces (EAF), ladle furnaces (LF) and high-current rectifiers need a specific design to supply the necessary… Read more
Sep 23, 2013 | By Edvard Csanyi
MCset – Air Insulated Switchgear with SF6 CB
MCset is Schneider Electric‘s AIS – Air Insulated Switchgear (indoor metal-enclosed device) intended for the MV section of HV/MV substations and high power MV/MV substations up to 24kV. Main component of MCset is circuit breaker which is SF6 type. MCset – Air… Read more
May 31, 2013 | By Edvard Csanyi
Things You Should Know About Medium Voltage GIS
Environmental Concerns Safety Concerns Special Handling Procedures Installation Concerns Operation and Maintenance Concerns End of Life / Recycling Concerns Conclusion Medium voltage (5-38 kV) gas insulated switchgear (GIS) differs greatly from the medium voltage AIS – Air insulated switchgear commonly… Read more
Feb 20, 2013 | By Edvard Csanyi
Medium Voltage Switchgear (2) – Selection of Switching Devices
Continued from first part: Medium Voltage Switchgear (1) – Basics of Switching Devices Switching devices are selected both according to their ratings and according to the switching duties to be performed, which also includes the switching rates. Selection according to… Read more
Feb 13, 2013 | By Emmanouil Angeladas
The Basics of Switching Devices In Medium Voltage Switchgear (Part 1)
According to international rules, there are only two voltage levels: Low voltage: up to and including 1kV AC (or 1,500V DC) and High voltage: above 1kV AC (or 1,500V DC). Most electrical appliances used in household, commercial and industrial applications work with low… Read more
Feb 11, 2013 | By Emmanouil Angeladas
Differences Between Earthed and Unearthed Cables
In HT electrical distribution, the system can be earthed or unearthed. The selection of unearthed or earthed cable depends on distribution system. If such system is earthed, then we have to use cable which is manufactured for earthed system. (which… Read more
Jan 21, 2013 | By Jignesh Parmar
Arrangements of LV Utility Distribution Networks (2)
Continued from the previous part: Arrangements of LV Utility Distribution Networks (1) In the past, an underground cable service or the wall-mounted insulated conductors from an overhead line service, invariably terminated inside the consumer’s premises, where the cable-end sealing box, the utility… Read more
Dec 01, 2012 | By Edvard Csanyi
Arrangements of LV Utility Distribution Networks
In European countries the standard 3-phase 4-wire distribution voltage level is 230/400 V. Many countries are currently converting their LV systems to the latest IEC standard of 230/400 V nominal (IEC 60038). Medium to large-sized towns and cities have underground… Read more
Nov 30, 2012 | By Edvard Csanyi
Electrical Safety Standards for LV/MV/HV (Part-3)
Continued from part 2 – Electrical Safety Standards for LV/MV/HV (Part-2) Standard: Northern Ireland Electricity (NIE), 6/025 ENA Code: Indian Electricity Rules / Central Electricity Authority Right of Way Clearance (As per GETCO Standard) Minimum clearances between Electrical Lines crossing… Read more
Nov 14, 2012 | By Jignesh Parmar
Electrical Safety Standards for LV/MV/HV (Part-2)
Continued from part 1 – Electrical Safety Standards for LV/MV/HV (Part-1) Standard: Northern Ireland Electricity (NIE), 6/025 ENA Clearances of Electrical Line to Ground and Roads Clearances of Electrical Line to Other Objects Clearances of Electrical Line to Trees and… Read more
Nov 12, 2012 | By Jignesh Parmar
Electrical Safety Standards for LV/MV/HV (Part-1)
Standard: Western Power Company Water Safely Clearance on Electrical Fires Minimum Approach Distance for Authorized Person Minimum Approach Distance for Ordinary Person Minimum Approach Distance for Vehicle and Plant for Ordinary Person . Standard: New Zealand Electrical Code Min. Safe… Read more
Nov 07, 2012 | By Jignesh Parmar
Testing and Commissioning of Metal-Clad Switchgear
Electrical testing and commissioning of Metal-Clad switchgear is essential to the safe start for the first time, regardless of its size, type or industry. This article covers testing and start-up / commisioning procedures for all the components of medium voltage… Read more
Sep 24, 2012 | By Edvard Csanyi
The major components of an Air Circuit Breaker and the Arc Interruption
The basic characteristics for air magnetic circuit breakers are maximum rationalization and constructional simplicity. The major components of such breakers are: the poles, the arc chutes, the base frame, the operating mechanism. The operating mechanism construction and parts are similar to that of… Read more
Jul 25, 2012 | By Edvard Csanyi