Relay and Metering Panel Schematics For the 1×8.6 MW Power Generation Project (PDF)
This technical article provides an in-depth technical analysis of the Relay and Metering Panel schematics, examining the attached engineering panel design document (PDF). The panel which we’ll discuss in great detail, serves as the central command node for electrical protection,… Read more
Aug 03, 2026 | By Edvard Csanyi
Thermal conditions of electrical equipment and temperature monitoring
Loose connections or worn out contact surfaces are the root causes of electrical system conduction troubles. They cause a local temperature increase, which worsens the contact quality even further as the current increases. This causes thermal runaway, which damages the… Read more
May 05, 2025 | By Edvard Csanyi
The true art of control, monitoring and protection provided by Substation Automation Systems
The Substation Automation Systems, often known as SASs, are responsible for a tremendous variety of tasks. These include some extremely important actions, such as clearing faults in a timely manner in order to maintain the physical condition of power system… Read more
Jul 01, 2024 | By Edvard Csanyi
What can go wrong with the nuclear power plant in the case of a grid loss: What to do?
Acquiring the skill to operate a nuclear reactor bears resemblance to acquiring the skill to pilot an aircraft. The majority of airplane pilots rapidly acquire proficiency in performing take-offs and landings. The process that requires significant time and exertion, particularly… Read more
Jan 22, 2024 | By Edvard Csanyi
Thoughtful considerations to design MV/LV distribution substations for extended service life
The installation of a new MV/LV electrical substation is often part of a more global project, and it is not always the subject of very detailed attention. However, the consideration of simple and practical criteria is not always dictated by… Read more
Sep 04, 2023 | By Power Systems and Services
SF6 Gas Monitoring and Alarming Practices in Gas-Insulated Switchgear (GIS) Systems
This article provides guidance on how to conduct gas monitoring and explains the various alerts that can be set. The many sorts of defects that might lead to partial discharges are discussed, and various partial discharge measuring techniques are described,… Read more
Apr 10, 2023 | By Edvard Csanyi
Isolation power solutions for ultimate power availability, efficiency and safety in hospitals
Things are changing fast, really fast. Technology we used a few years ago is now obsolete, and if you take a look for a second – it’s always about power availability, efficiency, and safety. This technical article deals with Schneider… Read more
Aug 04, 2021 | By Edvard Csanyi
Field devices and signals used for LV SCADA operations
At low voltage level, SCADA applications are usually used for process control and monitoring of equipment. Furthermore, incoming circuit breakers or switch disconnectors inside large LV switchboards may also be operated remotely, by the command given from the SCADA working…...
Membership Upgrade Required
This content is not available in your premium membership plan. Please upgrade your plan in order to access this content. You can choose an annually based Basic, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers.With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Good to know: - Save 50% on all video courses with Enterprise plan.
Upgrade
Sep 05, 2019 | By Miodrag Kokotovic
Five ingredients that make SCADA operation delicious
To explain in very simple words, I would say that SCADA is a bunch of equipment that provides an operator at a remote location with sufficient information to determine the status of particular equipment/process and make actions without being physically… Read more
Feb 04, 2019 | By Edvard Csanyi
Secondary equipment you should always consider when retrofitting existing HV substation
This approach assumes retrofitting and upgrading old substation secondary equipment such as intelligent electronic devices (IEDs), monitoring sensors, power apparatus, communication protocol and operating standards to improve the overall performance or reduce cost without disrupting the continuity of service. For… Read more
Sep 17, 2018 | By Edvard Csanyi
How to control and protect capacitor banks before something goes wrong
The purpose of a capacitor bank’s protective control is to remove the bank from service before any units or any of the elements that make up a capacitor unit are exposed to more than 110% of their voltage rating. When… Read more
Jan 24, 2018 | By Edvard Csanyi
How To Control Reactive Power In Larger Electrical Plants With Multiple Incomers
Most compensation banks are controlled stepwise. For this purpose it is essential to ‘know’ when it is allowed to (de)activate a capacitor step by the power factor relay (controller). The so-called C/k value is calculated by the step size C… Read more
Nov 15, 2017 | By Edvard Csanyi
Philosophy of a good relay protection settings for machines and plants
The objectives of the protection system are: to limit damage to people and to the plant, permit different service conditions, guarantee maximum service continuity for the plant not affected by faults and activate the automatisms provided. The protection relays are normally provided for different objectives… Read more
Jun 09, 2017 | By Edvard Csanyi
A case study of 110/10 kV substation with centralized protection, automation and control system
Centralized substation protection and control has been attempted in the past based on the available technology. This evolution is now at the intersection of sensing, protection and communication technologies, providing the unique opportunity to develop a more reliable and maintainable… Read more
Dec 21, 2016 | By Edvard Csanyi
This is why every industrial plant MUST have an alarm system (for monitoring processes)
In industrial plants and installations, control systems are used to monitor and control processes. Control Systems, whether a conventional Control Desk or a Computer/PLCs System with SCADA or a Distributed Control System (DCS), provides a human-machine-interface to monitor and control… Read more
Apr 01, 2016 | By Edvard Csanyi