Category 'Power Substation' - Technical Articles

Category “Power Substation” is dedicated to technical articles about a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high to low or the reverse using transformers. This also includes primary and secondary distribution, substation installation, testing and commissioning, erection and other important topics.

Power Substation

Responding to Cyber Intrusion in SCADA System

Continued from technical article: Detecting Cyber Intrusion in SCADA System The “three R’s” of the response to cyber intrusion are: Recording, Reporting, and Restoring. Theoretically, it would be desirable to record all data communications into and out of all substation… Read more

Apr 08, 2013 | By

Responding to Cyber Intrusion in SCADA System
Energy and Power

Detecting Cyber Intrusion in SCADA System

One of the axioms of cyber security is that although it is extremely important to try to prevent intrusions into one’s systems and databases, it is essential that intrusions be detected if they do occur. One of the axioms of… Read more

Apr 06, 2013 | By

Detecting Cyber Intrusion in SCADA System
Power Substation

Active fire protection measures in power substation

Active fire protection measures are automatic fire protection measures that warn occupants of the existence of fire, and extinguish or control the fire. These measures are designed to automatically extinguish or control a fire at its earliest stage, without risking… Read more

Apr 01, 2013 | By

Active fire protection measures in power substation
Medium Voltage

Things You Should Know About Medium Voltage GIS

Environmental Concerns Safety Concerns Special Handling Procedures Installation Concerns Operation and Maintenance Concerns End of Life / Recycling Concerns Conclusion Medium voltage (5-38 kV) gas insulated switchgear (GIS) differs greatly from the medium voltage AIS – Air insulated switchgear commonly… Read more

Feb 20, 2013 | By

Things You Should Know About Medium Voltage GIS
Energy and Power

Types and Applications Of Overcurrent Relay

Distribution systems are susceptible to overcurrent flow within its components. Overcurrent may arise from abnormal system conditions, including overloads and short-circuit failures, or from typical system conditions, such as transformer inrush current and motor initiation. Consequently, under typical system conditions,… Read more

Feb 01, 2013 | By

Types, applications and connections of Overcurrent relay
High Voltage

High Voltage Substations Overview (part 2)

Continued from first part: High Voltage Substations Overview (part 1) Transformers are used for the transformation of high and medium voltage to low voltage, flanked by specific protective devices and control systems, which constitute the low voltage distribution substations. A… Read more

Jan 26, 2013 | By

High Voltage Substations Overview (part 2)
High Voltage

High voltage substations overview (part 1)

High voltage substations are interconnection points within the power transmission and distribution systems between regions and countries. Different applications of substations lead to HV substations with and without power transformers: Step up from a generator voltage level to a high voltage… Read more

Jan 25, 2013 | By

Substations and Distribution Substations Overview
Energy and Power

What Is The Basic Insulation Level (BIL)

Insulation levels are designed to withstand surge voltages, rather than only normal operating voltages. Since the transmission & distribution lines and substation equipment are protected by surge arresters draining the surges rapidly before the insulation is damaged, the arrester must… Read more

Dec 03, 2012 | By

What Is The Basic Insulation Level (BIL)
Energy and Power

Arrangements of LV Utility Distribution Networks (2)

Continued from the previous part: Arrangements of LV Utility Distribution Networks (1) In the past, an underground cable service or the wall-mounted insulated conductors from an overhead line service, invariably terminated inside the consumer’s premises, where the cable-end sealing box, the utility… Read more

Dec 01, 2012 | By

Arrangements of LV Utility Distribution Networks
Energy and Power

Arrangements of LV Utility Distribution Networks

In European countries the standard 3-phase 4-wire distribution voltage level is 230/400 V. Many countries are currently converting their LV systems to the latest IEC standard of 230/400 V nominal (IEC 60038). Medium to large-sized towns and cities have underground… Read more

Nov 30, 2012 | By

Arrangements of LV Utility Distribution Networks
Power Substation

Steps to Ensure Effective Substation Grounding (Part 2)

Continued from previous article: Steps to Ensure Effective Substation Grounding (1) In previous technical article (part 1) was explained first five steps that will ensure a reliable, safe and trouble-free substation grounding system. Here we will explain the last six steps:… Read more

Nov 10, 2012 | By

Steps to Ensure Effective Substation Grounding
Power Substation

Steps to ensure effective substation grounding (Part 1)

An electrical substation is a critical resource in a power system. Safe operation of a substation calls for a properly designed and installed grounding system. A well-designed grounding system will ensure reliable performance of the substation over its entire service life. How does… Read more

Nov 09, 2012 | By

Steps to ensure effective substation grounding
Energy and Power

Testing and Commissioning of Current Transformer

This technical article is prepared to help the commissioning personnel effectively perform and carry out the testing and commissioning tasks on current transformers before taking the equipment to service condition. General testing procedures for the current transformers (CTs) described in… Read more

Oct 19, 2012 | By

Testing and Commissioning of Current Transformer