Category 'Power Substation' - Technical Articles

Category “Power Substation” is dedicated to technical articles about a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high to low or the reverse using transformers. This also includes primary and secondary distribution, substation installation, testing and commissioning, erection and other important topics.

Power Substation

Complete overview of lightning arresters (part 2)

Continued from article Complete overview of lightning arresters (part 1) Surge arresters are devices that help prevent damage to apparatus due to high voltages. The arrester provides a low-impedance path to ground for the current from a lightning strike or… Read more

Sep 29, 2011 | By

Complete overview of lighting arresters
High Voltage

GIS vs AIS – Substation Earthing

Compressed SF6 gas used in MV and HV switchgears as an insulating medium has led to the development of compact gas-insulated substation (CIS) technology (figure 1). GIS , having many advantages over often used and conventional air-insulated substations (AIS), have… Read more

Sep 12, 2011 | By

GIS vs AIS - Substation Earthing
High Voltage

AIS – Air insulated substations

In large, modern AC power systems, the transmission and distribution systems function to deliver bulk power from generating sources to users at the load centers. Transmission systems generally include generation switchyards, interconnecting transmission lines, autotransformers, switching stations, and step-down transformers…. Read more

Sep 06, 2011 | By

Air Insulated Packaged Substations and Components
Power Substation

Animal deterrents and security in substation

The vast majority of electrical utility substations designed to transform transmission voltages to distribution class voltages employ an open-air design. The configurations may vary, but usually consist of equipment that utilizes polymer or porcelain insulators or bushings to create electrically… Read more

Sep 05, 2011 | By

Six-foot black snake the culprit in power outage
High Voltage

Budgeting and Financing Substation

The construction of new substations and the expansion of existing facilities are commonplace projects in electric utilities. However, due to the complexity, very few utility employees are familiar with the complete process that allows these projects to be successfully completed…. Read more

Aug 16, 2011 | By

Budgeting and Financing Substation
Industrial Automation

How Stuxnet (PLC virus) spreads – Part 2

Continued from How Stuxnet (PLC virus) spreads – Part 1 » Read here Stuxnet is a computer worm designed to infect Siemens SIMATIC WinCC and S7 PLC products, either installed as part of a PCS 7 system, or operating on… Read more

Jul 23, 2011 | By

How Stuxnet (PLC virus) spreads
Power Substation

Electrical substation introduction and elements

An power substation is a subsidiary station of an electricity generation, transmission and distribution system where voltage is transformed from high or medium to low or the reverse using transformers. Electric power flows through several substations between generating plant and… Read more

Apr 29, 2011 | By

Electrical substation introduction and elements
Energy and Power

Protection Relay – ANSI Standards

In the design of electrical power systems, the ANSI Standard Device Numbers denote what features a protective device supports (such as a relay or circuit breaker). These types of devices protect electrical systems and components from damage when an unwanted… Read more

Feb 22, 2011 | By

Protection Relay - ANSI Standards
Power Substation

Risk and Consequences Of Transformer Fire

The risk of a catastrophic fire with a properly inspected, tested, and maintained transformer is small. Proper maintenance and thorough testing of the transformer will prevent or detect many events that could lead to explosion and/or fire. However, unforeseen events… Read more

Feb 07, 2011 | By

Risk and Consequences Of Transformer Fire
Power Substation

Substation Ventilation Requirements – Ergon

Substations require special attention to ventilation in order to dissipate heat losses from electrical equipment. Wherever possible, natural air flow to the outside of the building will be used. Forced ventilation should be used where natural ventilation is not practicable…. Read more

Jan 19, 2011 | By

Substation Ventilation Requirements – Ergon