Overvoltages Caused by Direct Lightning Strokes
A lightning stroke is defined as a direct stroke if it hits either the tower or the shield wire or the phase conductor. This is illustrated in Figure 1. When the insulator string at a tower flashes over by direct… Read more
Nov 29, 2011 | By Edvard Csanyi
Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)
The operation of an earth leakage circuit breaker (or shorten ELCB) is based on the fact that the algebraic sum of the currents in any healthy single phase, three phase and three phase and neutral system is zero. This simply… Read more
Nov 07, 2011 | By Jignesh Parmar
Transformer Winding Faults
A fault on a transformer winding is controlled in magnitude by the following factors: Source impedance Neutral earthing impedance Transformer leakage reactance Fault voltage Winding connection Several distinct cases arise and are examined below. The winding earth fault current depends… Read more
Nov 02, 2011 | By Edvard Csanyi
What is the difference between MCB, MCCB, ELCB, and RCCB
This technical article briefly describes the most common breaker-related protection devices in low-voltage applications: MCB, MCCB, ELCB, and RCCB. We’ll describe their main characteristics and limitations and try to solve some misunderstandings and differences that many young engineers mix up…. Read more
Oct 25, 2011 | By Jignesh Parmar
Short circuit protection of generator’s stator windings by overcurrent relays
If current transformers are not connected in the neutral ends of wye-connected generator windings, or if only the outgoing leads are brought out, protective devices can be actuated, as in Figure 1, only by the short-circuit current supplied by the… Read more
Oct 24, 2011 | By Edvard Csanyi
Neutral system – Single earthed or Multi earthed?
In distribution system three phase load is unbalance and non linear so the neutral plays an very important role in distribution system. Generally, distribution networks are operated in an unbalanced configuration and also service to consumers. This causes current flowing… Read more
Oct 13, 2011 | By Jignesh Parmar
Complete overview of lightning arresters (part 3)
Continued from article Complete overview of lightning arresters (part 2) There are several types of lightning arresters in general use. They differ only in constructional details but operate on the same principle, providing low resistance path for the surges to… Read more
Oct 08, 2011 | By Jignesh Parmar
Complete overview of lightning arresters (part 2)
Continued from article Complete overview of lightning arresters (part 1) Surge arresters are devices that help prevent damage to apparatus due to high voltages. The arrester provides a low-impedance path to ground for the current from a lightning strike or… Read more
Sep 29, 2011 | By Jignesh Parmar
Complete overview of lightning arresters (1)
Lightning can create voltage surges in several of the following ways. Lightning can score a direct hit on your house. It can strike the overhead power line which enters your house, or a main power line that is blocks away… Read more
Sep 23, 2011 | By Jignesh Parmar
Animal deterrents and security in substation
The vast majority of electrical utility substations designed to transform transmission voltages to distribution class voltages employ an open-air design. The configurations may vary, but usually consist of equipment that utilizes polymer or porcelain insulators or bushings to create electrically… Read more
Sep 05, 2011 | By Edvard Csanyi
Bus protection – Overcurrent differential
When selecting relays for bus protection, a major concern is the ability of the protective relaying scheme to restrain from tripping for close-in line faults. Tripping for bus faults, the reason for installing bus differential relaying, is less of a… Read more
Aug 31, 2011 | By Edvard Csanyi
Surge arrester types and auxiliary equipment
Nearly 100 years ago, electrode gaps (rod, sphere, or pipe) were used to limit overvoltages on equipment (Sakshaug, 1991). Some of these systems, particularly pipe gaps, may still be in service today. However, the characteristic of gap sparkover voltage vs…. Read more
Aug 25, 2011 | By Edvard Csanyi
Capacitor protection by surge arresters – ABB
Generally speaking, capacitor protection by surge arresters has been a difficult task before ZnO arresters became available. The high discharge currents and possible energies associated with an arrester operation at a capacitor bank heavily stressed the spark gaps in a… Read more
Aug 22, 2011 | By Edvard Csanyi
Applications and forms of differential relays
Differential relays take a variety of forms, depending on the equipment they protect. The definition of such a relay is “one that operates when the vector difference of two or more similar electrical quantities exceeds a predetermined amount. It will… Read more
Aug 15, 2011 | By Edvard Csanyi
Whole-House Protection Strategy
No single SPD (Surge Protection Strategy) can protect all the equipment in a residence from all causes of electrical surges. Instead, a whole-house protection strategy, consisting of point-of-entry and point-of-use SPDs, is necessary to help guard against disturbances from inside… Read more
Aug 13, 2011 | By Edvard Csanyi