How to manipulate energized conductors with hot stick
Hot sticks are poles made of an insulating material. They have tools and/or fittings on the ends which allow workers to manipulate energized conductors and equipment from a safe distance. Hot sticks vary in length depending on the voltage level… Read more
Jan 28, 2013 | By Edvard Csanyi
7 Golden Safety Rules for Working In HV Laboratory
Employees performing operations and testing work in high voltage laboratory are exposed to a greater hazard than most other employees. Safety rules MUST NOT be seen as a means of limiting our freedom, but should rather be looked upon as valuable… Read more
Dec 26, 2012 | By Edvard Csanyi
21 Safety Rules for Working with Electrical Equipment
A safe work environment is not always enough to control all potential electrical hazards. You must be very cautious and work safely. Safety rules help you control your and others risk of injury or death from workplace hazards. The good… Read more
Dec 12, 2012 | By Edvard Csanyi
What is the difference between Bonding, Grounding and Earthing?
One of the most misunderstood and confused concept is difference between Bonding, Grounding and Earthing. Bonding is more clear word compare to Grounding and Earthing, but there is a micro difference between Grounding and Earthing. Earthing and Grounding are actually… Read more
Sep 27, 2012 | By Jignesh Parmar
What psychological effect does an electric shock?
Most of us have experienced some form of electric ”shock”, where electricity causes our body to experience pain or trauma. If we are fortunate, the extent of that experience is limited to tingles or jolts of pain from static electricity… Read more
Dec 25, 2011 | By Edvard Csanyi
Earthing in electrical network – purpose, methods and measurement
The main reason for doing earthing in electrical network is for the safety. When all metallic parts in electrical equipment are grounded then if the insulation inside the equipment fails there are no dangerous voltages present in the equipment case…. Read more
Dec 19, 2011 | By Jignesh Parmar
Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)
The operation of an earth leakage circuit breaker (or shorten ELCB) is based on the fact that the algebraic sum of the currents in any healthy single phase, three phase and three phase and neutral system is zero. This simply… Read more
Nov 07, 2011 | By Jignesh Parmar
Be extremely careful when racking in and racking out circuit breaker
There are many reasons causes arc flash incidents. Some of arc flash explosions occur when substation personnel insert or remove (rack in or out) circuit breakers from low or high voltage switchgear cubicles. Manual racking in and racking out circuit… Read more
Oct 11, 2011 | By Edvard Csanyi
Types and Origins of Substation Fires
The risk of fire in substations has been historically low, but the possible impacts of a fire can be catastrophic. Fires in substations can severely impact the supply of power to customers and the utility company’s revenue and assets. These… Read more
Dec 26, 2010 | By Edvard Csanyi