Transformer Routine Test – Measurement of Voltage Ratio and Check of Phase Displacement
The no-load voltage ratio between two windings of a transformer is called turn ratio. The aim of measurement is: Confirming the no-load voltage ratio given in the customer order specifications, determining the conditions of both the windings and the connections… Read more
Mar 02, 2013 | By Edvard Csanyi
Transformer Routine Test – Measurement Of No-Load Loss And Current
The no-load losses are very much related to the operational performance of a transformer. As long as the transformer is operated, these losses occur. For this reason, no load losses are very important for operational economy. No-load losses are also… Read more
Feb 18, 2013 | By Edvard Csanyi
Testing and Commissioning of MV/HV Cables
Compare cable data with drawings and specifications. Inspect exposed sections of cables for physical damage. Inspect bolted electrical connections for high resistance using one or more of the following methods: Use of a low-resistance ohmmeter in accordance with Section 1.2 above…. Read more
Jan 12, 2013 | By Edvard Csanyi
Testing and Commissioning of Substation DC System
Power substation DC system consists of battery charger and battery. This is to verify the condition of battery and battery charger and commissioning of them. Following instruments will be used for testing: Multimeter. (Learn how to use it) Battery loading… Read more
Jan 09, 2013 | By Edvard Csanyi
Transformer routine test – The measurement of winding resistance
Measurement is made to check transformer windings and terminal connections and also both to use as reference for future measurements and to calculate the load loss values at reference (e.g. 75ºC) temperature. Measuring the winding resistance is done by using… Read more
Jan 05, 2013 | By Edvard Csanyi
Inspection and Test Procedures for Metal-Enclosed Busways
Visual and Mechanical Inspection Electrical Tests Test Values Test Values – Visual and Mechanical Test Values – Electrical Tables: TABLE 100.12 – US Standard Fasteners Bolt-Torque Values for Electrical Connections TABLE 100.1 – Insulation Resistance Test Values Electrical Apparatus and… Read more
Dec 22, 2012 | By Edvard Csanyi
Inspection and Test Procedures for LV Cables
Visual and Mechanical Inspection Electrical Tests Test Values TABLE 100.12 – US Standard Fasteners – Bolt-Torque Values for Electrical Connections Compare cable data with drawings and specifications. Inspect exposed sections of cables for physical damage and correct connection in accordance with… Read more
Nov 27, 2012 | By Edvard Csanyi
Testing and Commissioning of Current Transformer
This technical article is prepared to help the commissioning personnel effectively perform and carry out the testing and commissioning tasks on current transformers before taking the equipment to service condition. General testing procedures for the current transformers (CTs) described in… Read more
Oct 19, 2012 | By Edvard Csanyi
Switching Impulse Test of the Transformer
The switching impulse test is applied to confirm the withstand of the transformer’s insulation against excessive voltages occurring during switching. During the switching impulse voltage test, the insulation between windings and between winding and earth and withstand between different terminals… Read more
Oct 11, 2012 | By Edvard Csanyi
Measurement of insulation resistance (IR) – Part 2
This article goes into details of insulation resistance values measured by Megger tester on many different kinds of equipment, such as switchgear, electrical wires & cables, electric motors, transmission & distribution lines, and other power system equipment. An insulation tester… Read more
Apr 29, 2012 | By Jignesh Parmar
Measurement of insulation resistance (IR)
The measurement of insulation resistance is a common routine test performed on all types of electrical wires and cables. As a production test, this test is often used as a customer acceptance test, with minimum insulation resistance per unit length… Read more
Apr 28, 2012 | By Jignesh Parmar
Erection Procedures For Medium Voltage Switchgear
Before commencing erection of medium voltage (MV) switchgear check that all connections are tight on busbars and on main and auxiliary circuits. Examine the insulation carefully, because there have been cases of burned out connections due to failure to observe… Read more
Apr 03, 2012 | By Edvard Csanyi
Megger Insulation Resistance Test
As you know good insulation has high resistance and poor insulation relatively low resistance. The actual resistance values can be higher or lower, depending upon such factors as the temperature or moisture content of the insulation (resistance decreases in temperature… Read more
Mar 13, 2012 | By Edvard Csanyi
What is HIPOT Testing (Dielectric Strength Test)?
Hipot Test is short name of high potential (high voltage) Test and it is also known as Dielectric Withstand Test. A hipot test checks for “good isolation”. Hipot test makes surety of no current will flow from one point to… Read more
Dec 22, 2011 | By Jignesh Parmar