Category 'Transmission and Distribution' - Technical Articles

The “Transmission and Distribution” category contains technical articles dedicated to electricity transmission and distribution in high—and medium-voltage fields. This includes T&D equipment such as transmission and distribution lines, power transformers, capacitor banks, etc. Special attention is paid to installing, testing, and commissioning MV and HV equipment and troubleshooting various problems that may arise in power grids.

Transmission and Distribution

How Distribution Systems Control Customer Loads?

Distribution systems obviously exist to supply electricity to end users, so loads and their characteristics are important. Utilities supply a broad range of loads, from rural areas with load densities of 10 kVA/mi2 to urban areas with 300 MVA/mi2. A… Read more

Dec 10, 2012 | By

How Distribution Systems Control Customer Loads?
High Voltage

Methods of Controlling Lightning Overvoltages in HV

For well shielded transmission lines, the backflashover condition, close to the substation, is of prime concern for determining the location and number of surge arresters required to achieve insulation coordination of the substation for lightning surges. The risk of a… Read more

Dec 08, 2012 | By

Methods of Controlling Lightning Overvoltages in HV
Energy and Power

What Is The Basic Insulation Level (BIL)

Insulation levels are designed to withstand surge voltages, rather than only normal operating voltages. Since the transmission & distribution lines and substation equipment are protected by surge arresters draining the surges rapidly before the insulation is damaged, the arrester must… Read more

Dec 03, 2012 | By

What Is The Basic Insulation Level (BIL)
Energy and Power

Arrangements of LV Utility Distribution Networks (2)

Continued from the previous part: Arrangements of LV Utility Distribution Networks (1) In the past, an underground cable service or the wall-mounted insulated conductors from an overhead line service, invariably terminated inside the consumer’s premises, where the cable-end sealing box, the utility… Read more

Dec 01, 2012 | By

Arrangements of LV Utility Distribution Networks
Energy and Power

Arrangements of LV Utility Distribution Networks

In European countries the standard 3-phase 4-wire distribution voltage level is 230/400 V. Many countries are currently converting their LV systems to the latest IEC standard of 230/400 V nominal (IEC 60038). Medium to large-sized towns and cities have underground… Read more

Nov 30, 2012 | By

Arrangements of LV Utility Distribution Networks
High Voltage

The Purpose of High Voltage Circuit Switchers

Circuit switchers have been developed to overcome some of the limitations of fusing for substation power transformers. Circuit switchers have SF6 gas interrupters and are designed to provide three-phase interruption (solving the unbalanced voltage considerations) and to provide protection for… Read more

Nov 16, 2012 | By

Vertical interrupter circuit switcher without integral disconnect switch
Transformers

Transformers Are Never Silent

Yes, we all know that transformers are never silent. This is actually quite impossible, but in an environmentally aware, highly regulated world, the issue is not the level of noise, but its nature – and it’s very important. Transformers emit… Read more

Oct 29, 2012 | By

A three-phase oil transformer 225 MVA, 275 kV
Protection

Overcurrent protection of transformer (NEC 450.3)

The overcurrent protection required for transformers is consider for Protection of Transformer only. Such overcurrent protection will not necessarily protect the primary or secondary conductors or equipment connected on the secondary side of the transformer. Introduction Overcurrent protection of transformers… Read more

Oct 08, 2012 | By

Overcurrent protection of transformer (NEC 450.3)
Power Substation

Designing of HV Power Substation and Layout

Introduction Earthing and Bonding Substation Earthing Calculation Methodology (Earthing Materials) Layout of Substation Different Layouts for Substations (single busbar, mesh, 1 1/2 cb) Principle of Substation Layouts (spatial separation, maintenance zones) Components of a Substation (cbs, cts, isolators, insulation, transformers etc.) Substations are the… Read more

Oct 01, 2012 | By

Designing of High Voltage Power Substation and Layout
High Voltage

Design of Overhead Transmission Line Foundation

The foundation is the name given to the system which transfers to the ground the various steady state (dead) and variable (live) loads developed by the transmission tower and conductors. Foundations may be variously subjected to compressive or bearing forces,… Read more

Sep 19, 2012 | By

Design of Overhead Transmission Line Foundation
Energy and Power

An Overview Of Smart Power Grid

The present electric grids use the technology of 1970’s. But with the advancement in various concepts of power generation, problems associated with power outages and thefts, and also due to increase in demand, we require a modernized grid to avail… Read more

Aug 20, 2012 | By

An Overview Of Smart Power Grid