Search

Premium Membership

Study specialized technicalg articles, papers & video courses in low/high voltage areas. Save 50% on all courses at the EEP Academy with the Enterprise Plan.

Protection requirements for a large scale wind park
Protection requirements for a large scale wind park

Abstract

In the past wind power plants typically had a small power rating when compared to the strength of the connected electrical network and the behavior of the wind mills during faults in the network was considered non critical and wind power plants were simply pulled out of the system.

Hence protection requirement of a wind mill was just restricted to simple current and voltage based measurement.

This paper identifies the areas of concern where proper protection has to be introduced apart from the basic wind park requirements.

Owing to the increase in demand for renewable energy large wind parks are constructed in deep seas. Such wind parks are connected to the electrical grid on the land by comprehensive underground cables.

The underground cables are a potential for a fault occurrence. The next area of concern would be in the multiple mechanically switched capacitor banks or FACTS used for dynamic reactive compensation. The voltage flicker produced by large wind parks owing to the varying speed of the wind mills on the interconnected grid has a deteriorating effect on the other connected equipment and also on the grid as well.

To maintain voltage stability as per NERC guidelines and to mitigate voltage flickers, dynamic reactive compensation can be provided with multiple mechanically switched capacitor banks or FACTS.

Therefore the paper will discuss in detail the protection possibilities for the underground cables and the reactors for large wind parks located offshore.

This paper will focus on the following:

  1. Introduction and analysis of the various electrical fault possibilities in an offshore wind park.
  2. Detection and prevention against Ferro resonance due to inductive reactance introduced by wind generators, reactors and capacitive reactance introduced by the long running cables and capacitor banks.
  3. Automatic fault collection and analysis, and its benefits.
Title:Protection requirements for a large scale wind park – Shyam Musunuri, Siemens Energy
Format:PDF
Size:365KB
Pages:14
Download:Right here | Video Courses | Membership | Download Updates

Protection requirements for a large scale wind park

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

One Comment


  1. chen ronado
    Jun 09, 2020

    HELLO, SIR , Good afternoon
    I want to get the full text:
    Protection requirements for a large scale wind park – Shyam Musunuri, Siemens Energy
    Please help me

Leave a Reply to chen ronado

Tell us what you're thinking... we care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

96  −    =  ninety four

EEP Academy Video Courses

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning.