Cable ladder and cable tray systems

The following recommendations are intended to be a practical guide to ensure the safe and proper installation of cable ladder and cable tray systems and channel support and other support systems.

Best practice guide to cable ladder and cable tray systems
Best practice guide to cable ladder and cable tray systems (photo credit: elektro-ka.si)

These guidelines are not intended to cover all details or variations in cable ladder and cable tray installation and do not provide for every installation contingency.

It is recommended that the work described in this guide is carried out by competent persons who are familiar with the products being installed and the safety standards associated with them.

Channel type trapeze hangers - Installation with ladder and tray
Channel type trapeze hangers – Installation with ladder and tray

Structural characteristics

When considering the installation of the cable supports system it is imperative to avoid the cutting or drilling of structural building members without the approval of the project leader on site.

Cable ladders, cable trays and their supports should be strong enough to meet the load requirements of the cable management system including cables and any future cable additions and any other additional loads applied to the system.

Support systems can be broken down into a number of elements or components. To design a safe system it is necessary to check each element in turn to ensure:

  1. That it can safely support the loads being imposed upon it,and
  2. That the proposed fixings to adjacent components are also sufficient for the intended load
  3. That any declared deflection limits are note exceeded.

Consult the manufacturer for any further assistance on system design.

On many occasions cable ladder or cable tray is installed in circumstances where it will only ever carry a light cable load, possibly just one or two cables, and its main role is to physically secure and protect its contents.

In these situations it is often the inherent ruggedness or the aesthetics of the cable ladder or cable tray design which bear most heavily on the specification decision.

However, when a support system is required to be more heavily loaded it is useful to have knowledge of the theoretical aspects of rudimentary structural design in order to ensure that the completed system does fulfil its purpose with the greatest safety and economy.

Title:Best practice guide to cable ladder and cable tray systems – BEAMA
Format:PDF
Size:1.6 MB
Pages:73
Download:Right here | Video Courses | Membership | Download Updates
Best practice guide to cable ladder and cable tray systems – BEAMA
Best practice guide to cable ladder and cable tray systems – BEAMA

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Engr Abba Babagana
    Jun 26, 2020

    All you post is superb and very helpful to me.
    Thanks very much .keep it up .
    Abba


  2. ALEXANDARBESKI
    Oct 11, 2016

    sir,

    all documents could not able to download ,keep on loading ,can u send me directly to mail.

Leave a Reply to Engr Abba Babagana

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

three  +  5  =  

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).