Design calculations
Design calculations establish minimum guidelines and requirements for generating electrical calculations on projects. Electrical calculations should be made for all projects that include electrical components and should be filed in the project notebook.

Design calculations may be made either manually or by computer programs. At a minimum, the following types of calculations should be made where applicable:
- Load calculations
- Conductor sizing
- Conduit sizing
- Motor branch circuit sizing
- Power factor improvement
- Transformer primary and secondary circuit sizing
- Voltage drop
- Motor starting voltage dip
- Short circuit analysis
- Lighting levels
- Grounding in substations (where step potentials are of concern)
- Harmonic distortion analysis
- Cable pulling calculations
- Generator capability/motor starting.
Load
Load calculations should be made using applicable sections of NEC Articles 220, 430, and otherĀ sections of the NEC.
The following load calculations should generally be used for sizing:
- Feeder conductors and protective devices
- Transformers
- Panelboard and switchboard main busses
- Motor control center components
- Service entrance devices and conductors
An allowance must be made for future loadĀ growth. The loads for each branch of the distribution system can then be summed back to theĀ service entrance equipment.
Generator Sizing
The following information is intended to familiarize the design engineer with terms used byĀ generator sizing software and underlying formulas.
Generator single or multi-sets must be sized to supply maximum starting (SkVA), stead-stateĀ running (RkVA) and non-linear (GkW) demands of connected and future electrical equipment.
Information critical to the sizing and selection of generator single or multi-sets include:
- Environmental conditions: elevation, temperature, indoor or outdoor
- Noise abatement requirements: mufflers, enclosure, silent models
- Fuel: diesel, gasoline, natural gas
- Fuel storage: skid mounted tank, day and remote tanks
- Cooling: liquid cooled radiator, forced air
- Voltage regulation: maximum allowable voltage dips
- Operation: prime, standby
- Voltage ratings: voltage, 3-phase, 1-phase, solid grounded, delta, wye
- Connected loads: Linear, non-linear, power factor
- Load operation: Motor starting methods, single step, single step with diversity, multipleĀ steps of loading
- Future loads
Sizing Procedures for Generator Single or Multi-sets
The following is the sizing procedure for generator single or multi-sets:
- Prepare a load schedule.
- Enter individual load characteristics in software.
- Enter loads in step sequence in software.
- Have software calculate and select a generator set.
It is a good practice to request a verifying calculation from the preferred genset manufacturer.
Title: | Electrical Design Calculations Needed For Projects – Seattle Public Utilities |
Format: | |
Size: | 460 KB |
Pages: | 34 |
Download: | Right here | Video Courses | Membership | Download Updates |

thats good
this training have very helpfull and i am very thanks to you
thank you very much
I am very much interested in the electrical design calculations
thanks
THANK YOU
Really a good reference to review or check .. in need.
Thanks
Gracias. si esta buenissimo
Thanks ! Great Help in our day to day work
Regards
Muchas gracias por tan valiosa infomacion me gustaria que me ayuden con el calculos de tendidos de lineas y tablero de distribucion para 500KVA MUCHAS GRACIAS.. Atte. PEDRO
Thanks
I wante to share your fundametal knowlage of eletrical design
THANK YOU VERY MUCH, HELP ME ABOUT EXAMPLE ELECTRICAL DESIGN CALCULATIONS.YOU CAN USE MY EMAIL ADDRESS: [email protected]
I suggest making the audio of all your excellent articles, it permits for no English spoken to familiarized with the electrical sound and vocabulary. Thanks for the excellent work
I think Good subject