Design calculations
Design calculations establish minimum guidelines and requirements for generating electrical calculations on projects. Electrical calculations should be made for all projects that include electrical components and should be filed in the project notebook.

Design calculations may be made either manually or by computer programs. At a minimum, the following types of calculations should be made where applicable:
- Load calculations
- Conductor sizing
- Conduit sizing
- Motor branch circuit sizing
- Power factor improvement
- Transformer primary and secondary circuit sizing
- Voltage drop
- Motor starting voltage dip
- Short circuit analysis
- Lighting levels
- Grounding in substations (where step potentials are of concern)
- Harmonic distortion analysis
- Cable pulling calculations
- Generator capability/motor starting.
Load
Load calculations should be made using applicable sections of NEC Articles 220, 430, and other sections of the NEC.
The following load calculations should generally be used for sizing:
- Feeder conductors and protective devices
- Transformers
- Panelboard and switchboard main busses
- Motor control center components
- Service entrance devices and conductors
An allowance must be made for future load growth. The loads for each branch of the distribution system can then be summed back to the service entrance equipment.
Generator Sizing
The following information is intended to familiarize the design engineer with terms used by generator sizing software and underlying formulas.
Generator single or multi-sets must be sized to supply maximum starting (SkVA), stead-state running (RkVA) and non-linear (GkW) demands of connected and future electrical equipment.
Information critical to the sizing and selection of generator single or multi-sets include:
- Environmental conditions: elevation, temperature, indoor or outdoor
- Noise abatement requirements: mufflers, enclosure, silent models
- Fuel: diesel, gasoline, natural gas
- Fuel storage: skid mounted tank, day and remote tanks
- Cooling: liquid cooled radiator, forced air
- Voltage regulation: maximum allowable voltage dips
- Operation: prime, standby
- Voltage ratings: voltage, 3-phase, 1-phase, solid grounded, delta, wye
- Connected loads: Linear, non-linear, power factor
- Load operation: Motor starting methods, single step, single step with diversity, multiple steps of loading
- Future loads
Sizing Procedures for Generator Single or Multi-sets
The following is the sizing procedure for generator single or multi-sets:
- Prepare a load schedule.
- Enter individual load characteristics in software.
- Enter loads in step sequence in software.
- Have software calculate and select a generator set.
It is a good practice to request a verifying calculation from the preferred genset manufacturer.
Title: | Electrical Design Calculations Needed For Projects – Seattle Public Utilities |
Format: | |
Size: | 460 KB |
Pages: | 34 |
Download: | Here 🔗 (Get Premium Membership) | Video Courses | Download Updates |

Greetings,
How would i get pdf copy of electrical design and calculations book
How can I get a pdf copy of a electrical engineering design calculation
Hi there. How can I get a copy of the pdf file- electrical design calculation needed for project
May you send me a pdf of Electrical calculations for generator sizing power factor correction and load sizing
Thanks for your useful information
Can you send me the Electrical Design Calculation pdf.
Good
thank you
Very nice article. Can you please send me the PDF of Electrical design calculation as well?
Thank you very much.
how I can get PDF?
how can get the electrical calculations laws .. i’m electrical superviosor
This article is very informative.
Please send me the PDF copy.
Thank you.
please send the pdf of this topic: Electrical Design Calculations Needed For Projects
Thank, Can you send me the PDF..
I am beginner in Electrical engineering and would like to grow in terms of design. Please assist
Dear Sir,
Thanks. This article is much useful.
Good Day dear Arokia
Would you please to send me this file, I am interested to get this file
Thank you in advance
Sincerely
Nasser
Hello who may concern
Would you please to send me this pdf (electrical design calculations needed for projects)
I am interested to get this articular
Thank you in advance
Best regards
Nasser
I AM INTERESTED IN ELECTRICAL DESIGN CALCULATIONS , PLS KEEP ME UPDATED
thanks for the good job.
I’m interested in electrical design calculation on AC, and DC, and Solar system
am interested
thats good
this training have very helpfull and i am very thanks to you
thank you very much
I am very much interested in the electrical design calculations
thanks
THANK YOU
Really a good reference to review or check .. in need.
Thanks
Gracias. si esta buenissimo
Thanks ! Great Help in our day to day work
Regards
Muchas gracias por tan valiosa infomacion me gustaria que me ayuden con el calculos de tendidos de lineas y tablero de distribucion para 500KVA MUCHAS GRACIAS.. Atte. PEDRO
Thanks
I wante to share your fundametal knowlage of eletrical design
THANK YOU VERY MUCH, HELP ME ABOUT EXAMPLE ELECTRICAL DESIGN CALCULATIONS.YOU CAN USE MY EMAIL ADDRESS: [email protected]
I suggest making the audio of all your excellent articles, it permits for no English spoken to familiarized with the electrical sound and vocabulary. Thanks for the excellent work
I think Good subject