Practical guidance
Electrical hazards are a major cause of death and serious injury on construction sites. This industry standard provides practical guidance to employers, designers, manufacturers, importers, suppliers (including hirers), electrical contractors and electricians on eliminating or reducing the risk of electrocution and electric shock to any person.

This industry standard applies to:
- Fixed wiring,
- Construction wiring,
- Fixed and/or portable electrical apparatus,
- Tools,
- Appliances and
- Associated flexible cords used in construction work.
Construction work referred to in this industry standard means the construction, renovation and demolition of all types of buildings and structures including residential buildings and any related excavation work.
Electrical curcuits
Circuit breakers
Circuit breakers provide protection against circuit overload and fire. Every final sub-circuit must be protected by a circuit breaker except final sub-circuits exceeding 50A, which may be protected with high rupturing capacity (HRC) fuses.
RCD to final sub circuits
An RCD is a ‘safety switch’ fitted to an electrical circuit to reduce the risk of electric shock or electrocution. Every final sub-circuit including lighting and socket-outlets must be protected by an RCD with a rated tripping current not greater than 30mA. This also applies to the final sub-circuits in transportable structures.
This requirement need not apply to final sub- circuits supplying equipment such as cranes or personnel lifts where interruption of supply is a risk to safety.
| Title: | Electrical Installations On Construction Sites – WorkSafe Victoria |
| Format: | |
| Size: | 2.9Â MB |
| Pages: | 36 |
| Download: | Right here | Video Courses | Membership | Download Updates |

Hi ..am Selby Silabe am 25year old …am determined individual a having a recently qualification Electrical Engineering..N1,N2 & N3 ..and am currently Looking for a job..
Please i will be happy if my applications will be taken to consideration.. Please there’s my number 072 6399 662
A Passionate and highly motivated engineer specialized in Electrical and Electronics Engineering with focus on Electrical designing and Robotics. Have a significant understanding of designing software like autoCAD, ElectricalCAD and Revit MEP. Exhibit excellent analytic and problem solving skill and i happy To work for an organization which provides me the opportunity to improve my skills and knowledge growth along with the organization objectives.
I found this documentation very much interesting and helpful
An RCD is termed as a ‘safety switch’ which may – must not be correct. Any switch have only manual operation for ON or OFF i.e. without any protection. However, RCD trips during fault automatically.
Great work here
i like it but i really want to discuss another subjects
For new and old building electrical and plumbing & Fire fighting done here. Please contact : 8667453358.
For new home wiring or building construction contract wiring. Contact.9702920407
I wish to apply for an electrical technician in your company, looking forward to send you my resume
I’ know electric work Waring cabel install 7year UAE work now I’m living my country
I’ll be able to work in power. I pass the ninth grade. I have a hand in practice
Very nice article informative content thanks we liked it.
hi.very good programs.keep it up