Search

Premium Membership

Save 50% on all courses at the EEP Academy with the Enterprise Plan and study specialized technical articles, papers & video courses.

Home / Download Center / Electrical Engineering Books and Technical Guides / Electrical engineering guides / Electrical safety manual for students and young electricians

Plan your work and plan for safety

Take time to plan your work, by yourself and with others. Safety planning is an important part of any task. It takes effort to recognize, evaluate, and control hazards. If you are thinking about your work tasks or about what others think of you, it is hard to take the time to plan for safety.

Electrical safety manual for students and young electricians
Electrical safety manual for students and young electricians (photo credit: millerelect.com)

But, YOU MUST PLAN. Planning with others is especially helpful. It allows you to coordinate your work and take advantage of what others know about identifying and controlling hazards.

The following is a list of some things to think about as you plan:

To do #1 – Work with a “buddy”—Do not work alone.
Both of you should be trained in CPR. Both of you must know what to do in an emergency.

To do #2 – Know how to shut off and de-energize circuits
You must find where circuit breakers, fuses, and switches are located. Then, the circuits that you will be working on (even low voltage circuits) MUST BE TURNED OFF! Test the circuits before beginning work to make sure they are completely de-energized.

To do #3 – Plan to lock out and tag out circuits and equipment
Make certain all energy sources are locked out and tagged out before performing any work on an electrical circuit or electrical device.

Working on energized (“hot”) circuits is one of the most dangerous things any worker could do. If someone turns on a circuit without warning, you can be shocked, burned, or electrocuted.

The unexpected starting of electrical equipment can cause severe injury or death.

Before ANY work is done on a circuit, shut off the circuit, lock out and tag out the circuit at the distribution panel, then test the circuit to make sure it is de-energized.

Before ANY equipment inspections or repairs (even on so-called low voltage circuits) — the current must be turned off at the switch box, and the switch must be padlocked in the OFF position. At the same time, the equipment must be securely tagged to warn everyone that work is being performed. Again, test circuits and equipment to ensure they are de-energized.

No two locks should be alike. Each key should fit only one lock, and only one key should be issued to each worker. If more than one worker is working on a circuit or repairing a piece of equipment, each worker should lock out the switch with his or her own lock and never permit anyone else to remove it.

Title:Electrical safety manual for students and young electricians by National Institute for Occupational Safety and Health (NIOSH)
Format:PDF
Size:1.8 MB
Pages:88
Download:Right here | Video Courses | Membership | Download Updates
Electrical safety manual for students and young electricians by National Institute for Occupational Safety and Health (NIOSH)
Electrical safety manual for students and young electricians by National Institute for Occupational Safety and Health (NIOSH)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Melvis
    Jul 14, 2019

    Well


  2. andrew mclaren
    Mar 24, 2017

    this is basic information, but still the most important, it doesn’t matter if young or older, safety is sometimes taken for granted.
    be safe

Leave a Reply to andrew mclaren

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

ninety five  −    =  eighty seven

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).