Parallel DC Circuits

A circuit in which two of more electrical resistances or loads are connected across the same voltage source is called a parallel circuit. The primary difference between the series circuit and the parallel circuit is that more than one path is provided for the current in the parallel circuit.

Fundamental electrical knowledge and practical troubleshooting guide
Fundamental electrical knowledge and practical troubleshooting guide (photo credit: Arc Electric Inc.)

Each of these parallel paths is called a branch. The minimum requirements for a parallel circuit are the following:

  1. A power source.
  2. Conductors
  3. A resistance or load for each current path.
  4. Two or more paths for current flow.

Figure 1 depicts the most basic parallel circuit. Current flowing out of the source divides at point A in the diagram and goes through R1 and R2.

As more branches are added to the circuit, more paths for the source current are provided.

Basic parallel circuit
Figure 1 – Basic parallel circuit

Voltage Drops

The frst point to understand is that the voltage across any branch is equal to the voltage across all of the other branches.


Total Parallel Resistance

The voltage across any branch is equal to the voltage across all of the other branches. The parallel circuit consists of two or more resistors connected in such a way as to allow current flow to pass through all of the resistors at once. This eliminates the need for current to pass one resistor before passing through the next.

When resistors are connected in parallel, the total resistance of the circuit decreases. The total resistance of a parallel combination is always less than the value of the smallest resistor in the circuit.

In the series circuit, the current has to pass through the resistors one at a time. This gave a resistance to the current equal the sum of all the resistors. In the parallel circuit, the current has several resistors that it can pass through, actually reducing the total resistance of the circuit in relation to any one resistor value.

The amount of current passing through each resistor will vary according to its individual resistance. The total current of the circuit will then be the sum of the current in all branches. It can be determined by inspection that the total current will be greater than that of any given branch.

Using Ohm’s law to calculate the resistance based on the applied voltage and the total current, it can be determined that the total resistance is less than any individual branch.

Title:Fundamental electrical knowledge and practical troubleshooting guide
Format:PDF
Size:53.3 MB
Pages:180
Download:Here » Register First | Video Courses | Download Updates
Fundamental electrical knowledge and practical troubleshooting guide
Fundamental electrical knowledge and practical troubleshooting guide

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Md. Imran Hosen
    Sep 09, 2020

    i wil agree


  2. prakash Thanekar
    Apr 21, 2020

    we are held last week harmonic analyisis of our co gen plant remark of report come out harmonic current 15% to 22% and voltage distoration 4 to 5 % he recomended active harmoic filter but we are not conculed after installed active filter company pay return in money to how and which reason pl give detail

Leave a Reply to Md. Imran Hosen

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

thirty nine  ⁄  thirteen  =  

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).