Search

Premium Membership

Save 15% on Pro Premium Plan with discount code: UX778 (expires on October 31st). Study specialized LV/MV/HV technical articles and papers.

Electrical books and guides

Electrical engineering is a field of engineering  that generally deals with the study and application of electricity, electronics  and electromagnetism. Many companies and industry experts has been releasing technical books and guides in order to spread their knowledge, so they are all here, presented for you.

Nikola Tesla - Serbian-American inventor, mechanical engineer, and electrical engineer
Nikola Tesla – Serbian-American inventor, mechanical engineer, and electrical engineer

Introduction to energy generation

Prior to the discovery of Faraday’s Laws of electromagnetic discussion, electrical power was available from batteries with limited voltage and current levels. Although complicated in construction, D.C. generators were developed first to generate power in bulk.

However, due to limitation of the D.C. machine to generate voltage beyond few hundred volts, it was not economical to transmit large amount of power over a long distance. For a given amount of power, the current magnitude (I = P/V), hence section of the copper conductor will be large.

Thus generation, transmission and distribution of D.C. power were restricted to area of few kilometer radius with no interconnections between generating plants. Therefore, area specific generating stations along with its distribution networks had to be used.

In later half of eighties, in nineteenth century, it was proposed to have a power system with 3-phase, 50 Hz A.C generation, transmission and distribution networks.

Once A.C. system was adopted, transmission of large power (MW) at higher transmission voltage become a reality by using transformers. Level of voltage could be changed virtually to any other desired level with transformers – which was hitherto impossible with D.C system.

Browse guides and papers

Note that all documents in this section are free to download. Navigate through sub-pages to discover all documents.

Best Practice Manual For Transformers

Distribution transformers are very efficient, with losses of less than 0.5% in large units. Smaller units have efficiencies of 97% or above. It is estimated that transformer losses in power… Read more

Jan 27, 2012

Best Practice Manual For Transformers

PROFIBUS – Cabling and Assembly Guide

General plant or factory cabling can carry high voltages and currents. Running PROFIBUS cables parallel to such cables can lead to interference pickup and thus  to data transmission errors. Special… Read more

Dec 18, 2011

Lighting Handbook

Colour is a subjective psycho physiologic interpretation of the visible electromagnetic spectrum. Luminous sensations or images, produced in our retina, are sent to the brain and interpreted as a set… Read more

Sep 25, 2011

Lighting Handbook

Danfoss – From Real-World Applications

From real-world applications, for the real world is intended for the specialist controller and project engineer who wish to inform themselves about the possible applications of speed-controlled drives. Switching suggestions… Read more

Apr 14, 2011

Transmission And Distribution Electrical Engineering

A load flow analysis allows identification of real and reactive power flows, voltage profiles, power factor and any overloads in the network. Once the network parameters have been entered into…...

Premium Membership Required

This technical article/guide requires a Premium Membership. You can choose an annually based Plus, Pro, or Enterprise membership plan. Subscribe and enjoy studying specialized technical articles, online video courses, electrical engineering guides, and papers. With EEP's premium membership, you get additional essence that enhances your knowledge and experience in low- medium- and high-voltage engineering fields.
Check out each plan’s benefits and choose the membership plan that works best for you or your organization.
Save 15% - Get 15% discount on Pro Plan, apply discount code: UX778
Log In »Learn More »

Dec 08, 2010

Transmission And Distribution Electrical Engineering

Power Factor – The Basics

Super. I’m ready to find out what power factor is. To understand power factor, we’ll first start with the definition of some basic terms: To understand power factor, we’ll first… Read more

Dec 08, 2010

How To Apply Capacitors To Low Voltage Power Systems

In most modern electrical distribution systems, the predominant loads are resistive and inductive. Resistive loads are incandescent lighting and resistance heating. Inductive loads are A.C. Motors, induction furnaces, transformers and… Read more

Dec 08, 2010

How To Apply Capacitors To Low Voltage Power Systems

How Power Factor Corection Works

As with any equipment, an electrical system handles its job to some degree of efficiency ranging from poor to excellent. The measure of electrical efficiency is known as Power Factor…. Read more

Dec 08, 2010

How Power Factor Corection Works

Electrical Engineering Formulas

The theoretical foundation for EE is electromagnetism. The theory of classical electromagnetism is based on Maxwell’s equations, which provide a unified description of the behavior of electric and magnetic fields… Read more

Dec 08, 2010

85 Comments


  1. Tony Primachenko
    Oct 10, 2021

    Hello,

    Could you give me an idea how to wire two three phase air compressors from one sours?

    Only one compressor will run another is back up for emergency.

    And there will be a selector switch. Comp #1 & comp #2

    Thank you!

    Tony


  2. ISAAC SINGORO
    Aug 16, 2021

    Thanks for providing us with free articles, it is really helping me a lot to improve my skill in electrical field.


  3. Yahya Rashid
    Jul 15, 2021

    I want to upload some articles in EEP portal, but not been able to find a way. Please extend your help


  4. UAEU
    May 31, 2021

    Your article Awesome Thanks for this information, very informative as well as Modern.


  5. Abdulhakeem Dauda
    Aug 11, 2020

    Intrestive and educative want to learn and be a member


  6. med
    Apr 14, 2020

    I would like to thank you all for all this serious and helpful information


  7. dritan
    Mar 17, 2020

    Hello!
    Do you have any vocabulary for technical electric, devices?
    Thank you


  8. tfeld
    Feb 18, 2020

    how do i register?


    • Ahmed Cheikh
      Dec 21, 2020

      How to regist and pay fees


  9. Swapnil Raut
    Jan 07, 2020

    Hi,
    Can you please upload some useful stuff related to Electrical wiring harness and Electrical vehicle as well.

    Thanks


  10. Hein thu
    Nov 14, 2019

    I would like to know about low voltage distibution and protection system


  11. Godswill Essienta
    Aug 18, 2019

    thumbs up


  12. Bazeer Ali
    Aug 01, 2019

    Thanks a lot for your free service(providing free download).

    God bless you.

    Your website helping me/non electrical background persons lot.


    • Edvard
      Dec 14, 2019

      You’re welcome Ali, and thank you for the kind words.


  13. Leslie
    Jun 03, 2019

    Hello to everybody. I want to find a good textbook in English on Power Elecrical Systems for industrial enterprises, the design of power supply systems of industrial enterprises like Boeing, General Motors, Ford, VW, etc. I found some textbooks in Russian (Dr. Konyukhova, Moscow Power Energetic University) but I wish to have textbooks on the same topic by American authors. Who can be recommended?


  14. abhishek chandel
    May 31, 2019

    seriously you are a great man .
    , thank you very much.


  15. abhishek chandel
    May 31, 2019

    great work seriously , thank you very much.


    • Edvard
      May 31, 2019

      Thank you very much Abhishek.

Leave a Reply to Godswill Essienta

Tell us what you're thinking... we care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  ⁄  three  =  1

Learn to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Apply a 15% discount code EAB77 and enjoy learning!

Subscribe to Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and electrical guides.