Search

Premium Membership

Save 15% on Pro Premium Plan with discount code: UX778 (expires on October 31st). Study specialized LV/MV/HV technical articles and papers.

Home / Download Center / Electrical Engineering Books and Technical Guides / Electrical engineering guides / Power factor correction and harmonic filtering in electrical plants

Reactive Energy

In electrical plants the loads draw from the network electric power (active) as power supply source (e.g. personal computers, printers, diagnostic equipment, etc.) or convert it into another form of energy (e.g. electrical lamps or stoves) or into mechanical output (e.g. electrical motors).

Power Factor Correction And Harmonic Filtering - ABB
Power Factor Correction And Harmonic Filtering – ABB

To get this, it is often necessary that the load exchanges with the network (with net null consumption) the reactive energy, mainly of inductive type.

This energy, even if not immediately converted into other forms, contributes to increase the total power flowing through in the electrical network, from the generators, all along the conductors, to the users. To smooth such negative effect, the power factor correction of the electrical plants is carried out.

The power factor correction obtained by using capacitor banks to generate locally the reactive energy necessary for the transfer of electrical useful power, allows a better and more rational technical-economical management of the plants.

Moreover, the present spreading of direct current users, such as electronic circuits and electric drives, involve the generation of current harmonics which are injected into the network, with the consequent pollution and distortion of the waveforms on other connected loads.

Therefore, the use of harmonic filters, both of passive as well as of active type, contributes to improve the overall powerquality of the network, carrying out also power factor correction at the network frequency, when such filters are properly sized.


Generalities on power factor correction

In alternating current circuits, the current absorbed by a load can be represented by two components:

The active component IR, in phase with the supply voltage, is directly related to the output (and therefore to the part of electric energy converted into energy of different types: mechanical energy, light energy, thermal energy…);

The reactive component IQ, in quadrature to the voltage, is used to generate the flow necessary for the conversion of powers through the electric or magnetic field and it is index of the transfer of energy between supply and load. Without this, there could be no net transfer of power, for example, thanks to the magnetic coupling in the core of a transformer or in the air gap of a motor.

In the most common case, in the presence of ohmicinductive type loads, the total current I lags with respect to the active component IR.

Title:Power Factor Correction And Harmonic Filtering In Electrical Plants – ABB
Format:PDF
Size:1.1 MB
Pages:62
Download:Right here | Video Courses | Membership | Download Updates
Power Factor Correction And Harmonic Filtering - ABB
Power Factor Correction And Harmonic Filtering – ABB

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. victor
    Dec 10, 2019

    go ahead


  2. Vijaya
    May 25, 2017

    Very very nice

Leave a Reply to victor

Tell us what you're thinking... we care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

  +  eighteen  =  20

Learn to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Apply a 15% discount code EAB77 and enjoy learning!

Subscribe to Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and electrical guides.