Roadway Lighting

This Roadway Lighting Design Manual has been developed to provide training on the design of roadway lighting systems. Participants will learn the fundamentals needed to design lighting systems.

Roadway Lighting Design Manual
Roadway Lighting Design Manual

Example problems will help develop the concepts needed to understand and design a lighting system.

Contents

This Manual has been divided into 8 chapters:

  • Chapter 1 is the introduction.
  • Chapter 2 presents Lighting Basics with background information on lighting subjects.
  • Chapter 3 covers Lighting Equipment including lamps, luminaires, poles, ballasts, service cabinets, light bases, and equipment pads.
  • Chapter 4 covers the basics of Photometry.
  • Chapter 5 addresses the Mn/DOT Lighting Design methods and covers the Mn/DOT Lighting Plan Preparation steps.
  • Chapter 6 outlines Specifications and Agreements as pertaining to roadway lighting plans.
  • Chapter 7 contains two sample Mn/DOT Lighting Plans.
  • Chapter 8 is the Appendix with Glossary of Terms, References, a report titled Safety Benefits of Roadway Lighting, Standard Plates, a sample Special Provision, miscellaneous information, and an index.

Purpose

Traffic Engineering Objectives

  1. Promotion of safety at night by providing quick, accurate, and comfortable seeing for drivers and pedestrians.
  2. Improvement of traffic flow at night by providing light, beyond that provided by vehicle lights, which aids drivers in orienting themselves, delineating roadway geometries and obstructions, and judging opportunities for overtaking.
  3. Illumination in long underpasses and tunnels during the day to permit drivers entering such structures from the open to have adequate visibility for safe vehicle operation.

Other Objectives

  1. Reduction of street crimes after dark. From the traffic engineer’s perspective, this ancillary benefit could attract non-traditional funding sources.
  2. Enhancement of commercial (especially retail sales) properties by attracting evening shoppers, audiences, and other users.
Not all these objectives are necessarily achieved by good lighting alone.

Lighting at Intersections

Lighting at intersections is usually justified and will alert the driver to an approaching intersection. Luminaires should be placed on or near prominent conflict points.

Lighting should be provided at all signalized and flashing beacon intersections. A signal pole shaft extension with a luminaire mast arm should be utilized whenever possible to avoid adding more poles at the intersection. Street lights on traffic signal poles should be fed from the traffic signal service point.

Additional light poles may be necessary when the intersection has channelization or complex turning lanes.

The level of illumination of a signalized intersection is dictated by the area classification of the roadway. Suggested levels of illumination and average horizontal footcandles for roadway lighting are given in Chapter 5. The level of illumination at an intersection should be greater than that between intersections where there is continuous lighting.

Where the level of illumination is low between intersections, such as 0.6 footcandles, the light intensity at the intersection should be doubled as a rule.

Title:Roadway Lighting Design Manual – Department of transportation Minensota
Format:PDF
Size:2Mb
Pages:98
Download:Right here | Video Courses | Membership | Download Updates
Roadway Lighting Design Manual
Roadway Lighting Design Manual

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Megan Newberger
    Oct 20, 2020

    Very useful post i really appreciate this for sharing such a nice post…


  2. Vu Hung Cuong
    Aug 30, 2019

    I am a Lecturer in Electrical Engineering, so I need a source of modern documents like yours. Many thanks for support !

Leave a Reply to Megan Newberger

Tell us what you're thinking... we care about your opinion!

EEP Academy Video Courses

The learning platform for LV/MV/HV electrical engineers. Learn from experienced engineers and sharpen up your knowledge.