Search

Premium Membership

Save 15% on Pro Premium Plan with discount code: SX79 (expires on May 31st). Study specialized LV/MV/HV technical articles and papers.

Home / Download Center / Electrical Engineering Books and Technical Guides / Electricity generation, t&d guides / Class notes on electrical power transmission and distribution (for students, 6th semester)

Introduction to notes

The transmission line performance is based on its electrical parameters such as resistance, inductance and capacitance. As we know the transmission lines are used for delivering electrical power from one end to other end or one node to other node.

Class notes on electrical power transmission and distribution (for students, 6th semester)
Class notes on electrical power transmission and distribution (for students, 6th semester)

The path of power flow i.e. the transmission line can be represented as an electrical circuit having its parameters connected in a particular pattern. Since the transmission line consists of conductors carrying power, we need to calculate the resistance, inductance and capacitance of these conductors.


Resistance of transmission line

The resistance of the conductor (transmissmn line) can be determined by:

R = ρ × l / A

Where:

  • ρ is the resistivity of the wire in Ω-m,
  • i is the length m meters and
  • A is the cross sectional area mm2

When alternating current flows trough a conductor, the current density is not uniform over the entire cross section but is somewhat higher at the surface.

This is called the skin effect and this makes the AC resistance a little more than the DC resistance.

Moreover in a stranded conductor, the length of each strand is more that the length of the composite conductor thus increasing the value of the resistance from that calculated.


Inductance of transmission line

In order to determine the inductance of transmission line, we shall first drive expression for the inductance of a solid conductor and it will be extended to a single phase transmission line. Then we shall derive expression for inductance of a group of conductors and then extend it to three-phase transmission line.


Inductance of solid conductor

The inductance of solid conductor can be determined by calculating the flux linkage due to current flowing and using.

L = λ / I

Where: L  is the inductance in Henry, λ is the flux linkage in Weber-turns and I is the phasor current in Ampere.

Internal flux linkage of a round conductor
Figure 1 – Internal flux linkage of a round conductor

Inductance of solid conductor due to internal flux

Let us consider solid conductor of radius r [cm] and the current flowing I [A] as shown in figure above.

As we know Ampere’s law states that the magnetomotive forces mmf in ampere-turns around a closed path is equal to the net current in amperes enclosed in the path.

Title:Class notes on electrical power transmission and distribution for students (6th semester) – VSS University of Technology Burla, Sambalpur, Odisha,India
Format:PDF
Size:1.20 MB
Pages:108
Download:Right here | Video Courses | Membership | Download Updates
Class notes on electrical power transmission and distribution for students (6th semester)
Class notes on electrical power transmission and distribution for students (6th semester)

Premium Membership

Get access to premium HV/MV/LV technical articles, advanced electrical engineering guides, papers, and much more! It will help you to shape up your technical skills in your everyday life as an electrical engineer.
More Information

2 Comments


  1. Siva
    Nov 16, 2020

    Distribution and utilization


  2. Sadam husain
    Nov 03, 2020

    Suit student eng electrical

Leave a Reply to Sadam husain

Tell us what you're thinking. We care about your opinion! Please keep in mind that comments are moderated and rel="nofollow" is in use. So, please do not use a spammy keyword or a domain as your name, or it will be deleted. Let's have a professional and meaningful conversation instead. Thanks for dropping by!

78  +    =  eighty seven

Learn How to Design Power Systems

Learn to design LV/MV/HV power systems through professional video courses. Lifetime access. Enjoy learning!

Subscribe to Weekly Newsletter

Subscribe to our Weekly Digest newsletter and receive free updates on new technical articles, video courses and guides (PDF).